Page 1
3. Etegnex toute flamme hue vapeurs inflammables, a proximite 4. Contactez immediatement votre compangie de tout appareil fonctionnant au gaz de gaz Retain Instructions for Future Reference Part No. 4801-1015 Rev 6-09 Owners Manual Super-Saver XL Heater – 120 Volt...
Page 2
The intended use of this appliance is the heating of agricultural animal confinement buildings ELECTRICAL The electrical connections and grounding of the appliance shall be in compliance with the National Electrical Code ANSI/NFPA 70. Part No. 4801-1015 Rev 6-09 Super-Saver XL Heater – 120 Volt Page 2 of 25...
Gas pressure should be checked by a certified gas technician while heater is in operation. Refer to heater ratings plate for unit voltage, amperage, and frequency ratings. Part No. 4801-1015 Rev 6-09 Super-Saver XL Heater – 120 Volt Page 3 of 25...
17. Keep temperature of fuel containers below 100° F (37.8°C). Containers must be installed outside building. 18. Heater must not be operated for one hour following wash-down. Part No. 4801-1015 Rev 6-09 Super-Saver XL Heater – 120 Volt Page 4 of 25...
If this heater fails to operate during this period, return it intact and prepaid to Hired-Hand, Inc., 1733 Co Rd 68, Bremen, AL 35033 for repair or replacement without charge at the manufacturer’s option.
(B) to low pressure end regulator with special brass coupling. See page 1 for LP, and natural gas requirements. Fig. 2 Flexible hose High Pressure Line Part No. 4801-1015 Rev 6-09 Super-Saver XL Heater – 120 Volt Page 6 of 25...
Ventilation requirements are given in 'Specifications and Requirements' on page 1. Both installer and operator must ensure that the building’s ventilation rate never drops below the noted limits. Part No. 4801-1015 Rev 6-09 Super-Saver XL Heater – 120 Volt Page 7 of 25...
Outside Mount (Optional) Hired-Hand heaters are available in Outside Mount (OSM) models. These heaters are designed to be mounted to the outside wall of a building. This saves valuable space inside the building and ensures fresh air intake for the heater.
BURNER CONNECTORS 10 AMP FUSE ON/OFF SWITCH SAIL SWITCH MOTOR BLACK HIGH LIMIT SWITCH GAS VALVE INSIDE HEATER 120 Volts A.C. 60 Hz Single Phase Part No. 4801-1015 Rev 6-09 Super-Saver XL Heater – 120 Volt Page 9 of 25...
Hot Surface Ignition Control IGNITOR HSIG SAIL SWITCH FLAME SENSOR PROBE MAIN REDUNDANT VALVE VALVE HIGH LIMIT SWITCH 120 Volts A.C. 60 Hz Single Phase Part No. 4801-1015 Rev 6-09 Super-Saver XL Heater – 120 Volt Page 10 of 25...
If voltage exists between the terminal connected to the white wire and the chassis ground, the main power supply lines are improperly connected to the furnace. Reverse incoming line voltage leads. Part No. 4801-1015 Rev 6-09 Super-Saver XL Heater – 120 Volt Page 11 of 25...
Page 12
Return heater to operation and observe through at least one complete cycle to ensure all controls are operating properly. Perform gas leak test at outlet pressure tap plug. (Soap and water work well). Part No. 4801-1015 Rev 6-09 Super-Saver XL Heater – 120 Volt Page 12 of 25...
Page 13
Chart 1 First Visual Check Part No. 4801-1015 Rev 6-09 Super-Saver XL Heater – 120 Volt Page 13 of 25...
Page 14
Chart 2 Second Visual Check Part No. 4801-1015 Rev 6-09 Super-Saver XL Heater – 120 Volt Page 14 of 25...
Page 15
Chart 3 Third Visual Check Part No. 4801-1015 Rev 6-09 Super-Saver XL Heater – 120 Volt Page 15 of 25...
¾ inch (0.824 in.) (19.1 mm). Repeat for each pipe section. Heaters Part No. 4801-1015 Rev 6-09 Super-Saver XL Heater – 120 Volt Page 16 of 25...
Page 17
2047 1921 1811 1606 1496 Table values given in BTUH/1000. To convert to kW, multiply table values by 0.3. * 1 inch = 25.4 mm Part No. 4801-1015 Rev 6-09 Super-Saver XL Heater – 120 Volt Page 17 of 25...