PHOTOELECTRIC DETECTOR
AX-250PLUS, AX-500PLUS
AX-350TF, AX-650TF
Photoelectric detectors detect intruders when both the upper and lower invisible infrared beams are simultaneously broken.
Maximum detection range between Transmitter and Receiver for the AX-250PLUS is 250ft. (75m), the AX-500PLUS is 500ft. (150m) and for the
AX-350TF is 350ft. (100m), the AX-650TF is 650ft. (200m)
FEATURES
• Beam interruption time adjustment
• Anti-Frost Structure
• Alignment level monitor jack
• Form C relay
• Tamper
• Option
• UL Listed
AX-350TF, AX-650TF ONLY
• LED indicator for fi ne beam alignment level
• Selectable beam frequencies
• Re-Transmit Circuit
• D.Q.Circuit (Environmental Disqualifi cation)
• Alarm Memory
For Safe Use of the Product
• Read this instruction manual carefully prior to installation.
• After reading, store this manual carefully in an easily accessible place for reference.
• This manual uses the following warning indications for correct use of the product and harm to you or other people and damage to your assets, which
are described below. Be sure to understand the description before reading the rest of this manual.
WARNING
Failure to follow the instructions provided with this indication and improper handling may cause death or serious injury.
Failure to follow the instructions provided with this indication and improper handling may cause injury
CAUTION
and / or property damage.
This symbol indicates prohibition. The specifi c prohibited action is provided in and/or around the fi guer.
This symbol requires an action or gives an instruction.
Do not use the product for purposes other than the detection of moving objects such as people and vehicles.
Do not use the product to activate a shutter, etc., which may cause an accident.
Do not touch the unit base or power terminals of the product with a wet hand (do not touch when the
product is wet with rain, etc.). It may cause electric shock.
WARNING
Never attempt to disassemble or repair the product. It may cause fi re or damage to the devices.
Do not exceed the voltage or current rating specifi ed for any of the terminals during installation, doing so
may cause fi re or damage to the devices.
Do not pour water over the product with a bucket, hose, etc. The water may enter, which may cause damage
to the devices.
CAUTION
Clean and check the product periodically for safe use. If any problem is found, do not attempt to use the
product as it is and have the product repaired by a professional engineer or electrician.
1.PARTS IDENTIFICATION ····································· P2
2.PRECAUTIONS ····················································· P2
3.INSTALLATION METHOD ···································· P3
4-1.TERMINAL ······················································ P4
4-2.WIRING ··························································· P4
4-3.OPTICAL ALIGNMENT ·································· P5
5-1.TERMINAL ······················································ P6
5-2.WIRING ··························································· P6
5-3.OPTICAL ALIGNMENT ·································· P7
Please read intsructions completely before beginning installation.
: This function allows you to select the suitable beam interruption time for any environment.
: Prevents fog and condensation from blocking the beams.
: Can easily obtain maximum optical alignment by checking the voltage from this jack.
: Form C relay for more applications.
: N.C., Opens when cover is removed.
: Heating unit (HU-1), Back cover (BC-1) AX-Beam Tower (AX-BT)
: For UL Listed applications, the heating unit (HU-1) shall not be installed with the models AX-350TF and AX-650TF.
: The optical alignment level can be checked at the Reciver.
: Crosstalk is eliminated with 4, channel selectable, beam frequencies. Used when stacking beams
or for long range applications.
: The advantage of this method is the elimination of wiring, from a detector or switch, back to the
control panel.
: The environmental compensation circuit is designed to eliminate false alarms caused by snow,
fog, heavy rain, ice and misalignment.
C O N T E N T S
< STANDARD >
< 4 SELECTABLE BEAM FREQUENCIES >
6.BEAM INTERRUPTION
TIME ADJUSTMENT ············································ P8
7-1.SELECTABLE BEAM FREQUENCIES ·········· P8
7-2.ALARM MEMORY ·········································· P8
7-3.DQ CIRCUIT ··················································· P9
7-4.RE-TRANSMITTING CIRCUIT ······················· P9
8.SPECIFICATIONS ··············································· P10
9.DIMENSIONS ······················································ P10
CHECK SHEET ············································ P11,P12
1
No. 59-1365-4 0902-05

INSTALLATION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AX-250PLUS and is the answer not in the manual?

Questions and answers

Summary of Contents for Optex AX-250PLUS

  • Page 1: Table Of Contents

    Photoelectric detectors detect intruders when both the upper and lower invisible infrared beams are simultaneously broken. Maximum detection range between Transmitter and Receiver for the AX-250PLUS is 250ft. (75m), the AX-500PLUS is 500ft. (150m) and for the AX-350TF is 350ft. (100m), the AX-650TF is 650ft. (200m) FEATURES •...
  • Page 2: Parts Identification

    1. PARTS IDENTIFICATION (AX-350/650TF Receiver only) (AX-350/650TF only) (AX-350/650TF only) STANDARD ACCESSORIES ○ Screws (4×20 Self tapping)×8 ○ Screws (M4×30)×8 ○ U-Shaped brackets ×4 ○ Beam Blocking Tool ×2 2. PRECAUTIONS 2. Do not install the unit where objects 3. Prevent direct sunlight 1.
  • Page 3: Installation Method

    Installation Method Detection range and installation height. Maximum distances between Receiver and Transmitter are listed below. AX-250PLUS = 250ft (75m) Max AX-500PLUS = 500ft (150m) Max Lossen the cover lock screw and remove the front cover. And loosen the...
  • Page 4: Ax-250/500Plus

    19000' (5800m) AWG16 (1.31mm 5000' (1500m) 30000' (9200m) UL requires AX-250PLUS/500PLUS to be connected to a UL listed power supply capable of providing a norminal input of 12VDC, (10.5~30VDC) 50mA and battery standby time of 4 hours. 4-2. WIRING 1 Set...
  • Page 5: 4-3.Optical Alignment

    4-3. OPTICAL ALIGNMENT When using two or more units on wire, the maximum length is obtained by dividing the maximum wire length listed below of units used. Power wires should not exceed the following lengths. Rough alignment by Looking through the view fi nder, locate the other detector in the center of the sights by adjusting vertically and horizontally.
  • Page 6: Ax-350/650Tf

    5. AX-350/650TF 5-1. TERMINAL Receiver Transmitter CAUTION : Make sure to connect the jumper (U-shaped connector), when not using the retransimitting circuit. If the jumper is not connected, the Transmitter will not transmit beam (Alarm condition). Wiring Distance When using two or more units on one wire, the maximum length is obtained by dividing the wire length listed below by the number of units used.
  • Page 7: 5-3.Optical Alignment

    5-3. OPTICAL ALIGNMENT When using two or more units on wire, the maximum length is obtainted by dividing the maximum wire length listed below of units used. Power wires should not exceed the following lengths. Beam Frequencies ○ Match the frequency settings. (See Sec. 7-1 SELECTABLE BEAM FREQUENCIES.) Selection STEP1...
  • Page 8: Time Adjustment

    6. BEAM INTERRUPTION TIME ADJUSTMENT The beam interruption time adjustment is on Receiver unit. This function allows you to match the units sensitivity ti its surroundings. Slower steeings reduce sensiticity. Interruption Switches time Running Jogging Walking Slow movement (2.4m/s) (1.2m/s) (0.5m/s) (0.3m/s) 50ms...
  • Page 9: 7-4.Re-Transmitting Circuit

    7-3. DQ CIRCUIT (ENVIRONMENTAL DISQUALIFICATION) D.Q. will send a trouble signal when the beam strength is below an acceptable level due to heavy fog, rain, snow or other changes in the installation site. The trouble signal output continues as long as the beam strength is below an acceptable level. It will reset when the environmental conditions clear.
  • Page 10: Specifications

    8. SPECIFICATIONS MODEL AX-250PLUS AX-500PLUS AX-350TF AX-650TF Detection Method Infrared Photoelectric Outdoor 250ft(75m) 500ft(150m) 350ft(100m) 650ft(200m) Range Indoor 500ft(150m) 1000ft(300m) 700ft(200m) 1300ft(400m) Maximum Arrival Distance 2500ft(750m) 5000ft(1500m) 3500ft(1000m) 6500ft(2000m) Beam Characteristics Pulsed Infrared Selectable Beam Frequency — 4 channel Interruption Period...
  • Page 11: Trouble Shooting

    10. TROUBLE SHOOTING CHECK SHEET for AX-250PLUS/500PLUS/350TF/650TF 1. “No Action” on the TRANSMITTER or RECEIVER after power has been applied. Disconnect power cable from the power supply and the Photoelectric beam and test for short or open circuit. Also test for short circuit to ground.
  • Page 12 These units are designed to detect an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion. These products conform to the EMC Directive 2004/108/EC. OPTEX CO., LTD. (JAPAN) OPTEX INCORPORATED (USA) OPTEX SECURITY Sp.z o.o. (POLAND) TEL:+1-909-993-5770 TEL:+48-22-598-06-55 (ISO 9001 Certified) Tech:(800)966-7839 URL:http://www.optex.com.pl...

This manual is also suitable for:

Ax-650tfAx-500plusAx-350tf

Table of Contents

Save PDF