North Star 5500 IPG Owner's Manual

Industrial portable generator

Advertisement

MODEL 5500 IPG, ITEM # 165926
Industrial Portable Generator
M165926A
P r o v e n
P e r f o r m a n c e
OWNER'S MANUAL
5500 IPG
00219
Shown with Optional Wheel Kit (Item # 165916)
Any Questions, Comments, or Problems?
Call Customer Service at 1-800-270-0810
Hours: Monday - Friday 7:30 AM to 5:30 PM
Saturday 7:30 to 11:30 AM CST

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5500 IPG and is the answer not in the manual?

Questions and answers

Summary of Contents for North Star 5500 IPG

  • Page 1 MODEL 5500 IPG, ITEM # 165926 Industrial Portable Generator M165926A P r o v e n P e r f o r m a n c e OWNER’S MANUAL 5500 IPG 00219 Shown with Optional Wheel Kit (Item # 165916)
  • Page 2: Table Of Contents

    Everyone who operates this generator must read and understand this manual. The time you take now will prolong your generator’s life and prepare you for its safe operation. Enjoy the exceptional performance of your North Star Industrial Series Generator.
  • Page 3: Specifications

    SPECIFICATIONS Item Number Ma ximum Output Continuous Output Voltage Phase Frequency Power Factor Engine Engine Speed Fuel Type Fuel Capacity Oil Capacity Starting Method 120 V Receptacle 120/240 V Receptacle Circuit Breaker Grounding Post Dimensions Length Width Height Dry Weight Gross Weight #165926 5500 Watts (W)
  • Page 4: Machine Component Identification

    MACHINE COMPONENT IDENTIFICATION Figure 1 (Ref. 1-7) Ref. Description Air Cleaner Starting/Stopping Instructions Oil Drain Plug Control Panel Gas Cap with Gauge 6.5 Gallon Gas Tank Super Silent Muffler Gas Drain Valve Figure 2 (Ref. 8-16) 00229 Ref. Description Gas Line Valve Generator Head Battery &...
  • Page 5: Generator Features

    GENERATOR FEATURES Reference 1 - Air Cleaner. Refer to your Honda engine manual for air cleaner care. Reference 2 - Starting/Stopping Instructions. Reference 3 - Oil Drain Plug. Refer to your Honda engine manual for oil change recommendations. Reference 4 - Control Panel. See Fig. 3 for details. Reference 5 - Gas Cap with Gauge.
  • Page 6: Introduction

    North Star is constantly improving its products. The assumes liability of any modification Before using, the user shall determine the suitability of ANSI SAFETY DEFINITIONS DANGER indicates...
  • Page 7: Installation

    ALWAYS remove the spark plug or spark plug wire before working on the engine or generator, to prevent accidental starting. ALWAYS provide adequate ventilation. Do not operate generator in any enclosed or narrow space. consume oxygen and give off deadly carbon monoxide poisonous gas.
  • Page 8: Extension Cords

    are easier to start and usually require 2 to 4 times as much current to start than to run. Repulsion Induction motors are the easiest to start and require 1.5 to 2.5 times as much to start than to run. Most fractional motors take about the same amount of current to run them whether they are of Repulsion- Induction (RI), Capacitor (Cap), or Split-Phase (SP) type.
  • Page 9: Pre-Start Up Preparation

    Slow Cooker Submersible Pump (1-1/2 HP) Submersible Pump (1 HP) Submersible Pump (1/2 HP) Sump Pump Table Saw (10”) Television Toaster Vacuum cleaner Water Heater Weed Trimmer (a) Hard-starting motors require 3 to 5 times the rated running watts. (b) These loads may require up to 15 minutes to restart due to its normal build up of compressor head pressure.
  • Page 10: Starting - Electric

    STARTING - ELECTRIC 1. Disconnect all loads to generator. 2. Turn gas line valve to ON position. 3. For cold engine, move choke lever to full choke position, for warm engine, move choke lever to half choke or to RUN position. 4.
  • Page 11: Troubleshooting

    TROUBLESHOOTING Problem Possible Causes Engine will not start. a) Low oil level. b) Fouled spark plug. c) Out of fuel. d) Stop switch in OFF position. e) Battery has lost its charge. Voltage too low. a) Engine speed too slow. b) Generator is overloaded.

Table of Contents

Save PDF