SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS No. OB319 REVISED EDITION-A utilized SERVICE MANUAL R410A Inverter-controlled multi system type Models MXZ-A14WV - MXZ-A18WV - MXZ-A26WV - MXZ-A32WV - CONTENTS Indication of model name 1. TECHNICAL CHANGES ····································2 MXZ-A18WV - 2. PART NAMES AND FUNCTIONS······················6 3.
TECHNICAL CHANGES MXZ-14WV - New model MXZ-18TV - MXZ-A18WV - 1. Outdoor model has been changed. 2. Refrigerant has been changed. (R22 R410A) MXZ-24UV - MXZ-A26WV - 1. Cooling capacity has been made larger. (7.1kW 7.2kW) 2. Combinations of connectable indoor units have been increased. 3.
Page 3
INFORMATION FOR THE AIR CONDITIONER WITH R410A REFRIGERANT • This room air conditioner adopts an HFC refrigerant (R410A) which never destroys the ozone layer. • Pay particular attention to the following points, though the basic installation procedure is same as that for R22 conditioners. 1 As R410A has working pressure approximate 1.6 times as high as that of R22, some special tools and piping parts/ materials are required.
Page 4
Conversion chart of refrigerant temperature and pressure (MPa [Gauge]) R410A NOTE : The unit of pressure has been changed to MPa on the international system of units(SI unit system). The conversion factor is: 1(MPa [Gauge]) =10.2(kgf/f f [Gauge]) -0.5 -30 -20 -10 1.Tools dedicated for the air conditioner with R410A refrigerant The following tools are required for R410A refrigerant.
Page 5
2 Flaring work and flare nut Flaring work for R410A pipe differs from that for R22 pipe. For details of flaring work, refer to Installation manual “FLARING WORK”. Dimension of flare nut Pipe diameter R410A 6.35 9.52 12.7 15.88 3.Refrigerant oil Apply the special refrigeration oil (accessories: packed with indoor unit) to the flare and the union seat surfaces.
INDOOR UNITS COMBINATION MXZ-A14WV - NOTE: Electrical data is for outdoor unit only. Cooling capacity (kW) Current Outdoor unit Power Indoor units power consumption factor Total combination Unit A Unit B (kW) 230V 0.750 – 3.62 (0.9-2.95) (0.230-1.000) 0.810 –...
MXZ-A18WV - NOTE: Electrical data is for outdoor unit only. Cooling capacity (kW) Current Power Outdoor unit Indoor units power consumption factor combination Total Unit A Unit B (kW) 230V 0.750 – 3.62 (0.9-2.95) (0.225-1.000) 0.810 – 3.91 (0.9-3.30) (0.225-1.070) 1.180 –...
Page 11
MXZ-A26WV - NOTE: Electrical data is for outdoor unit only. Cooling capacity (kW) Outdoor unit Power Indoor units Current power consumption factor Total Unit A Unit B Unit C combination (kW) 0.710 – – 3.12 (1.4-3.0) (0.400-0.920) 0.760 – – 3.34 (1.4-3.3) (0.400-1.010)
Page 12
NOTE: Electrical data is for outdoor unit only. Cooling capacity (kW) Outdoor unit Power Indoor units Current power consumption factor Total Unit A Unit B Unit C combination (kW) 2.390 07+09+26 1.54 4.45 10.50 (2.9-8.5) (0.680-2.530) 2.350 07+12+12 1.62 2.79 2.79 10.32 (2.9-8.5)
Page 13
NOTE: Electrical data is for outdoor unit only. Heating capacity (kW) Outdoor unit Power Indoor units Current power consumption factor Total Unit A Unit B Unit C combination (kW) 1.050 – – 4.61 (1.2-4.2) (0.340-1.380) 1.110 – – 4.87 (1.2-4.5) (0.340-1.510) 1.210 –...
Page 14
NOTE: Electrical data is for outdoor unit only. Heating capacity (kW) Outdoor unit Power Indoor units Current power consumption factor Unit A Unit B Unit C Total combination (kW) 2.020 07+09+26 1.92 5.57 8.87 (2.6-11.0) (0.510-3.040) 2.180 07+12+12 2.03 3.48 3.48 9.57 (2.6-11.0)
Page 15
MXZ-A32WV - NOTE: Electrical data is for outdoor unit only. Cooling capacity (kW) Outdoor unit Power Indoor units Current power consumption factor Total Unit A Unit B Unit C Unit D combination (kW) 0.710 – – – 3.12 (1.4-3.0) (0.400-0.920) 0.760 –...
Page 16
NOTE: Electrical data is for outdoor unit only. Cooling capacity (kW) Outdoor unit Power Indoor units Current power consumption factor Total combination Unit A Unit B Unit C Unit D (kW) 2.370 07+09+18 1.62 2.09 4.18 – 10.41 (2.9-9.0) (0.700-2.920) 2.390 07+09+24 –...
Page 17
NOTE: Electrical data is for outdoor unit only. Cooling capacity (kW) Outdoor unit Power Indoor units Current power consumption factor Total Unit A Unit B Unit C Unit D combination (kW) 7.95 2.210 07+07+09+12 9.71 1.59 1.59 2.04 2.72 (3.7-9.2) (0.810-2.650) 2.150 07+07+09+18...
Page 18
NOTE: Electrical data is for outdoor unit only. Heating capacity (kW) Outdoor unit Power Indoor units Current power consumption factor Total combination Unit A Unit B Unit C Unit D (kW) 1.050 – – – 4.61 (1.2-4.2) (0.340-1.380) 1.110 – –...
Page 19
NOTE: Electrical data is for outdoor unit only. Heating capacity (kW) Outdoor unit Power Indoor units Current power consumption factor Total combination Unit A Unit B Unit C Unit D (kW) 2.100 07+09+18 1.93 2.48 4.97 – 9.22 (2.6-11.6) (0.510-3.330) 2.100 07+09+24 1.64...
Page 20
NOTE: Electrical data is for outdoor unit only. Heating capacity (kW) Outdoor unit Power Indoor units Current power consumption factor Total combination Unit A Unit B Unit C Unit D (kW) 1.940 07+07+09+12 1.88 1.88 2.41 3.22 8.52 (3.4-11.6) (0.590-3.390) 1.890 07+07+09+18 2.06...
NOISE CRITERIA CURVES MXZ-A18WV - MXZ-A14WV - FAN SPEED FUNCTION SPL(dB LINE FAN SPEED FUNCTION SPL(dB LINE High Cooling High Cooling High Heating High Heating Test conditions. Test conditions. Cooling :DB 35: WB 24: Cooling :DB 35: WB 24: Heating :DB 7:...
OUTLINES AND DIMENSIONS Unit: mm OUTDOOR UNIT MXZ-A14WV - MXZ-A18WV - REQUIRED SPACE Open as a rule More than100mm if the front and both sides are open Drainage More than 100mm More than Air in 3 holes 200mm or more if...
Page 25
Unit: mm OUTDOOR UNIT MXZ-A26WV - (200) 2-U-shape notched holes (Base bolt M10) Air in Rubber cushion Air in Veranda Base Air out Drainage holes 3-[33 2-12O36 Oval hole Gas pipe (Base bolt M10) [9.52(flared)3/8(B,C unit) [12.7(flared)1/2(A unit) Indoor and outdoor connect wiring 23O45 hole...
Page 26
Unit: mm OUTDOOR UNIT MXZ-A32WV - (200) 2-U-shape notched holes (Base bolt M10) Rubber cushion Air in Veranda Air in Base Air out Drainage holes 3-[33 2-12O36 Oval hole Gas pipe (Base bolt M10) [9.52(flared)3/8(C,D unit) [12.7(flared)1/2(A,B unit) Indoor and outdoor connect wiring 23O45 hole...
REFRIGERANT SYSTEM DIAGRAM MXZ-A14WV - Unit:mm MXZ-A18WV - R.V. coil Discharge heating ON Compressor temperature cooling OFF thermistor RT61 Refrigerant flow in cooling Refrigerant flow in heating Muffler Stop valve (with service port) 4-way valve Gas pipe temperature B thermistor...
MXZ-A26WV - Unit:mm Compressor Discharge High-pressure R.V. coil temperature Refrigerant flow in cooling switch heating ON thermistor RT61 Refrigerant flow in heating Oil separator cooling OFF Capillary tube Service port [2.5 [0.6 1000 Ball valve with service port 4-way valve Unit C gas pipe temperature thermistor Indoor unit...
MXZ-A32WV - Unit:mm Compressor Discharge High-pressure R.V. coil Refrigerant flow in cooling temperature switch heating ON Refrigerant flow in heating thermistor RT61 cooling OFF Oil separator Capillary tube Service port [2.5 [0.6 1000 Unit D gas pipe Ball valve with temperature thermistor Indoor unit [9.52...
PERFORMANCE CURVES MXZ-A14WV- MXZ-A18WV- MXZ-A26WV- MXZ-A32WV- The standard data contained in these specifications apply only to the operation of the air conditioner under normal conditions, since operating conditions vary according to the areas where these units are installed. The following information has been pro- vided to clarify the operating characteristics of the air conditioner under the conditions indicated by the performance curve.
Page 35
10-2. Capacity and input correction by inverter output frequency (OUTDOOR UNIT : MXZ-A14WV, MXZ-A18WV) 1. 07-class unit in single operation <COOL>Capacity <COOL>Total input <HEAT>Capacity <HEAT>Total input Frequency Frequency Frequency Frequency 2. 09-class unit in single operation <COOL>Capacity <COOL>Total input <HEAT>Capacity <HEAT>Total input...
Page 36
(OUTDOOR UNIT:MXZ-A26WV, MXZ-A32WV) 1. 07-class unit in single operation <COOL>Capacity <COOL>Total input <HEAT>Capacity <HEAT>Total input Frequency Frequency Frequency Frequency 2. 09-class unit in single operation <COOL>Capacity <COOL>Total input <HEAT>Capacity <HEAT>Total input Frequency Frequency Frequency Frequency 3. 12-class unit in single operation <COOL>Capacity <COOL>Total input <HEAT>Capacity...
Page 37
6. 26-class unit in single operation <COOL>Capacity <COOL>Total input <HEAT>Capacity <HEAT>Total input Frequency Frequency Frequency Frequency...
Page 38
10-3. Outdoor low pressure and outdoor unit current 1. 07-class unit in single operation (OUTDOOR UNIT : MXZ-A14WV, MXZ-A18WV) NOTE:The unit of pressure has been changed to MPa on the international system of units(SI unit system). The conversion factor is : 1(MPa[Gauge]) =10.2(kgf/f...
Page 39
2. 09-class unit in single operation (OUTDOOR UNIT : MXZ-A14WV, MXZ-A18WV) NOTE:The unit of pressure has been changed to MPa on the international system of units(SI unit system). The conversion factor is : 1(MPa[Gauge]) =10.2(kgf/f f [Gauge]) (1) COOL operation 1Both indoor and outdoor units are under the same <How to work fixed-frequency operation>...
Page 40
3. 12-class unit in single operation (OUTDOOR UNIT : MXZ-A14WV, MXZ-A18WV) NOTE:The unit of pressure has been changed to MPa on the international system of units(SI unit system). The conversion factor is : 1(MPa[Gauge]) =10.2(kgf/f f [Gauge]) (1) COOL operation 1Both indoor and outdoor units are under the same <How to work fixed-frequency operation>...
Page 41
4. 07-class unit in single operation (OUTDOOR UNIT : MXZ-A26WV, MXZ-A32WV) NOTE:The unit of pressure has been changed to MPa on the international system of units(SI unit system). The conversion factor is : 1(MPa[Gauge]) =10.2(kgf/f f [Gauge]) (1) COOL operation 1Both indoor and outdoor units are under the same <How to work fixed-frequency operation>...
Page 42
5. 09-class unit in single operation (OUTDOOR UNIT : MXZ-A26WV, MXZ-A32WV) NOTE:The unit of pressure has been changed to MPa on the international system of units(SI unit system). The conversion factor is : 1(MPa[Gauge]) =10.2(kgf/f f [Gauge]) (1) COOL operation 1Both indoor and outdoor units are under the same temperature/humidity condition.
Page 43
6. 12-class unit in single operation (OUTDOOR UNIT : MXZ-A26WV, MXZ-A32WV) NOTE:The unit of pressure has been changed to MPa on the international system of units(SI unit system). The conversion factor is : 1(MPa[Gauge]) =10.2(kgf/f f [Gauge]) (1) COOL operation 1Both indoor and outdoor units are under the same temperature/humidity condition.
Page 44
7. 18-class unit in single operation (OUTDOOR UNIT : MXZ-A26WV, MXZ-A32WV) NOTE:The unit of pressure has been changed to MPa on the international system of units(SI unit system). The conversion factor is : 1(MPa[Gauge]) =10.2(kgf/f f [Gauge]) (1) COOL operation 1Both indoor and outdoor units are under the same temperature/humidity condition.
Page 45
8. 24-class unit in single operation (OUTDOOR UNIT : MXZ-A26WV, MXZ-A32WV) NOTE:The unit of pressure has been changed to MPa on the international system of units(SI unit system). The conversion factor is : 1(MPa[Gauge]) =10.2(kgf/f f [Gauge]) (1) COOL operation 1Both indoor and outdoor units are under the same <How to work fixed-frequency operation>...
Page 46
9. 26-class unit in single operation (OUTDOOR UNIT : MXZ-A26WV, MXZ-A32WV) NOTE:The unit of pressure has been changed to MPa on the international system of units(SI unit system). The conversion factor is : 1(MPa[Gauge]) =10.2(kgf/f f [Gauge]) (1) COOL operation 1Both indoor and outdoor units are under the same temperature/humidity condition.
MICROPROCESSOR CONTROL 11-1. INVERTER MULTI SYSTEM CONTROL MXZ-A14WV - MXZ-A18WV - Output signal Input signal Compressor Compressor Compressor power primary secondary factor current current Indoor unit microprocessor Outdoor unit control microprocessor Drive SSR61 circuit Transistor module Fin temperature thermistor RT65 Comp.
Page 48
MXZ-A26WV - Output signal Input signal Indoor unit microprocessor Outdoor unit control microprocessor Fan motor drive Comp- IPM/PFC micropro- SSR61 Drive cessor ressor microprocessor primary current Drive Transistor Drive circuit module circuit Fin temperature thermistor RT65 module Compressor Transistor secondary module current Comp.
Page 49
MXZ-A32WV - Output signal Input signal Indoor unit microprocessor Outdoor unit control microprocessor Fan motor drive Comp- IPM/PFC micropro- SSR61 Drive ressor cessor microprocessor primary current Drive Transistor Drive circuit module circuit Fin temperature thermistor RT65 module Compressor Transistor secondary module current Comp.
Page 50
Fan speed is switched according to the number of operating indoor unit and the compressor frequency. Fan speed Down High Min. Compressor frequency Max. <Relation between compressor frequency and fan speed.> MXZ-A26WV, MXZ-A32WV MXZ-A14WV, MXZ-A18WV Indoor unit operation Indoor unit operation Mode Mode Fan speed Fan speed 1 unit 2 units...
Page 51
When the number of rotation is lowered to around 100 rpm, the fan may stop by the influence of wind, but restarts 30 seconds later. 11-7.RELATION BETWEEN MAIN SENSOR AND ACTUATOR Relation between main sensor and actuator. MXZ-A14WV, MXZ-A18WV Actuator Sensor Purpose...
• Check the indoor unit with referring to the indoor unit service manual, and confirm that there is any problem in the indoor unit. Then, check the outdoor unit with referring to this page. MXZ-A14WV - MXZ-A18WV - MXZ-A26WV -...
Page 53
12-3. Troubleshooting check table MXZ-A14WV - MXZ-A18WV - LED 1 (Red) LED 2 (Yellow) Error mode Lighting Lighting Normal Symptom: Outdoor unit does not operate. Indication Abnormal point Detecting method Check points LED 1 LED 2 (Red) (Yellow) When the drain abnormality is detected in the indoor unit and the indoor •...
Page 54
Symptom: Outdoor unit operates (The compressor operates at reduced frequency) Indication Abnormal point Detecting method Check points LED 1 LED 2 (Red) (Yellow) Once Lighting Current protection When the outdoor unit input current exceeds 13A. Twice Lighting High-pressure protection When indoor gas pipe temperature exceeds 55˚C during heating. Twice Lighting Defrosting in cooling When indoor gas pipe temperature falls to 6˚C or below during cooling.
Page 55
MXZ-A26WV - MXZ-A32WV - LED 1 (Red) LED 2 (Yellow) Error mode Lighting Lighting Normal Symptom: Outdoor unit does not operate. Indication Abnormal point Detecting method Check points LED 1 LED 2 (Red) (Yellow) When the drain abnormality is detected in the indoor unit and the indoor •...
Page 56
Symptom: It is repeated that outdoor unit stops and restarts 3 minutes later Indication Abnormal point Detecting method Check points LED 1 LED 2 (Red) (Yellow) • Check the outdoor unit air passage. • Check the outdoor fan motor. 4 times Goes out P.C. board temperature When the P.C.
Page 57
MXZ-A14WV - MXZ-A18WV - MXZ-A26WV - MXZ-A32WV - Part name Check method and criterion Defrost thermistor Measure the resistance using a tester. Evaporation/ Gas pipe/ (Part temperature : -10°C ~ 40°C) High-pressure protect/ Normal abnormal Outdoor heat exchanger Open or short-circuit 5kΩ...
Page 58
Outdoor unit does not operate. (LED display: display OFF) A A Check of power supply MXZ-A14/A18WV Start Check the connecting of parts of main power supply circuit. Turn on power supply. Is there voltage of 230V AC in the Check the power supply cable. power supply terminal block? Is there voltage of 230V AC across the Replace the noise...
Page 59
Outdoor unit does not operate. (LED display: Both LED1 and LED2 lighting) B B Check of outdoor unit serial signal Start 1. Check the indoor unit with referring to "How to check mis-wiring and serial signal error" in service manual of indoor unit. 2.
Page 60
The cooling operation or heating operation does not operate. (LED display: Both LED1 and LED2 lighting) C C Check of R.V. coil • When heating operation does not work. Start 1. Disconnect the lead wire leading to the compressor. 2. 3 minutes after turning on the power supply, start EMERGENCY OPERATION in HEAT mode.
Page 61
• When cooling, heat exchanger of non-operating indoor unit frosts. • When heating, non-operating indoor unit get warm. D D Check of LEV LED display: LED1 LED2 Lighting Lighting Lighting Once Start Turn on power supply to the outdoor unit after checking LEV coil is mounted to the LEV body securely.
Page 62
• When heating, room does not get warm. • When cooling, room does not get cool. E E Check of inverter/ compressor MXZ-A14/A18WV LED display: LED1 LED2 Lighting Lighting Lighting Twice Twice Goes out Start Disconnect the terminal of the compressor at terminals. 3 minutes after turning on the power supply, start EMERGENCY OPERATION.
Page 63
MXZ-A26/A32WV Start Disconnect the terminal of the compressor. 3 minutes after turning on the power supply, start EMERGENCY OPERATION. W • After the outdoor fan starts running, wait for 1 minutes or more before Measure the voltage between each measuring the voltage. •...
Page 64
• When thermistor is abnormal. (When the LED display is a table below.) F F Check of outdoor unit thermistors MXZ-A14/A18WV Start Abnormal Disconnect the connector in the outdoor electronic control P.C. board (see below table), Replace the thermistor. and measure the resistance of thermistor to check whether the thermistor is normal or not. Normal Reconnect the connector CN661, CN662 and CN663 on the outdoor electronic control P.C.
Page 65
• Fan motor does not operate or stops operating shortly after starting the operation. G G Check of outdoor fan motor MXZ-A14/A18WV Start Check the connection of connector CN851 in the fan motor relay connector and outdoor electronic control P.C. board at the noise filter P.C.
Page 66
• When the operation frequency does not go up from lowest frequency. H H Check of HPS MXZ-A26/A32WV Start 1. Disconnect the connector CN681 in the electronic control P.C. board. 2. Check the resistance of HPS after 1 minutes have passed since the outdoor unit power supply was turned off. Infinity Check the resistance between Replace HPS.
Page 67
MXZ-A14WV - MXZ-A18WV - Outdoor electronic control P.C. board Defrost temperature thermistor (RT62) Evaporation temperature thermistor (RT63) Gas pipe temperature thermistor (RT6A,6B) Fin temperature thermistor (RT65) Discharge temperature thermistor (RT61) High-pressure protection thermistor (RT68) 100 110 120 Temperature (;) 10 20 30 40 50 60 70 80 Temperature (;)
Page 68
Defrost temperature thermistor (RT62) MXZ-A26WV - MXZ-A32WV - Evaporation temperature thermistor (RT63) Gas pipe temperature thermistor (RT6A,6B) Outdoor electronic control P.C. board Fin temperature thermistor (RT65) Outdoor heat exchanger temperature thermistor (RT68) Discharge temperature thermistor (RT61) 10 20 30 40 50 60 70 80 100 110 120 Temperature (;) Temperature (;)
Page 69
MXZ-A14WV - MXZ-A18WV - F912 FUSE 230V AC 50Hz Noise filter P.C. board 3.15A/250V Input NR63 VARISTOR F911 FUSE 1A/250V 230V AC 50Hz Output CN912 R.V. Coil 230V AC CN911 Outdoor Fan Fan speed “High” 230V AC CN911 Outdoor Fan Fan speed “Low”...
Page 70
MXZ-A26WV - MXZ-A32WV - Outdoor Power board Connect to the compressor Voltage among phases: 5V to 180V 325-370V DC Output (Red) (–) (White) Connect to the earth Signal reception (From electronic control P.C. board) 5V DC pulse wave Fin temperature thermistor Primary current detection (Connect to the noise filter) Connect to the controller board...
DISASSEMBLY INSTRUCTIONS 13-1. MXZ-A14WV - MXZ-A18WV - OUTDOOR UNIT OPERATING PROCEDURE PHOTOS 1. Removing the cabinet. Photo 1 1. Removing the cabinet. (1) Remove the screws of the top panel. (2) Remove the top panel. (3) Remove the screw of the service panel.
Page 72
OPERATING PROCEDURE PHOTOS 3. Removing the Outdoor Electronic control P.C. board. Photo 5 Screws of the cover (1) Remove the top panel, service panel and front panel. (2) Remove the connector coming out of the compressor. Screws of fan motor (3) Remove the compressor connector, compressor relay connector on the electronic control P.C.
Page 73
OPERATING PROCEDURE PHOTOS 5. Removing the thermistor Photo 8 Discharge temperature thermistor, defrost, evaporator temperature, high-pressure protect, High-pressure protect thermistor gas pipe temperature A and gas pipe temperature B (1) Remove the top panel, service panel, front panel. (2) Remove indoor/outdoor connecting wire and power supply Defrost cable.
Page 74
OPERATING PROCEDURE PHOTOS 6. Removing the compressor/4-way valve Photo 10 (1) Collect refrigerant from refrigerant circuit. Caution: If collecting has not been done enough, refrigerating machine oil may spout out or harmful substance may be generated during welding work. (2) Remove indoor/outdoor connecting wire and power supply cable.
Page 75
13-2. MXZ-A26WV - MXZ-A32WV - OUTDOOR UNIT OPERATING PROCEDURE PHOTOS 1. Removing the compressor Photo 1 Screws of the top panel (1)Remove the screws of the top panel, and remove it. (2)Remove the screws of the service panel, and remove it. Recover refrigerant gas.
Page 76
PHOTOS OPERATING PROCEDURE Photo 4 2. Removing the fan motor (1)Remove the top panel, the service panel, and the front panel. Screws of the outdoor fan motor (Photo 1) (2)Disconnect the connector CN911 on the outdoor electronic control P.C. board. (3)Remove the propeller.
Page 77
OPERATING PROCEDURE PHOTOS 5. Removing the reactor Photo 7 (1)Remove the top panel. (Photo 1) (2)Disconnect the reactor lead wire. (3)Remove the screws of the reactor, and remove the reactor. Screws of the reactor...
PARTS LIST MXZ-A14WV - MXZ-A18WV - 14-1. OUTDOOR UNIT FUNCTIONAL PARTS AND STRUCTURAL PARTS Part numbers that are circled are not shown in the illustration. Q'ty/unit Symbol in Wiring MXZ- MXZ- Parts No. Parts Name Remarks Diagram A14WV- A18WV- E02 819 521...
MXZ-A14WV - MXZ-A18WV - 14-2. OUTDOOR UNIT 14-3. ACCESSORY ELECTRICAL PARTS 14-2. OUTDOOR UNIT ELECTRICAL PARTS Part numbers that are circled are not shown in the illustration. Q'ty/unit Symbol in Wiring MXZ- MXZ- Parts No. Parts Name Remarks Diagram A14WV-...
Page 80
MXZ-A26WV - MXZ-A32WV - 14-4. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS 7 8 9 10...
Page 81
14-4. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS Part numbers that are circled are not shown in the illustration. Q'ty/unit Symbol in Wiring Parts No. Parts Name Remarks MXZ-A26WV- MXZ-A32WV- Diagram M21 TK0 232 FRONT PANLE M21 TK0 027 HANDLE ASSEMBLY M21 TK5 010 GRILLE M21 TK0 245...
Page 82
MXZ-A26WV - MXZ-A32WV - 14-5. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS Part numbers that are circled are not shown in the illustration. Q'ty/unit Symbol in Wiring Parts No. Parts Name Remarks MXZ-A26WV- MXZ-A32WV- Diagram M21 TK0 501 PROPELLER M21 TK0 301 OUTDOOR FAN MOTOR PM8H60- T2W TK0 440...
MXZ-A26WV- MXZ-A32WV- Diagram DRAIN SOCKET O1 T2W E59 704 DRAIN SOCKET ASSEMBLY DRAIN CAP O2 OPTIONAL PARTS 15-1. Different-diameter pipe Unit : mm (inch) MXZ-A14WV Connected pipes Length Length Length Model name diameter (mm) MXZ-A18WV For different- {9.52 — {12.7 {9.52...
Page 84
HEAD OFFICE: MITSUBISHI DENKI BLDG.,2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO100-8310, JAPAN C C Copyright 2004 MITSUBISHI ELECTRIC ENGINEERING CO.,LTD Distributed in Aug. 2004. No.OB319 REVISED EDITION-A 8 New publication, effective Aug. 2004 Distributed in Dec. 2003. No.OB319 7 Made in Japan Specifications subject to change without notice.
Need help?
Do you have a question about the MXZ-A14WV and is the answer not in the manual?
Questions and answers