Page 1
MhouseKit GD0 For the automation of a sectional or overhead door. Installation instructions and warnings ISTGD0-GBR01.4865 - Rev.00 - 15-04-2010...
- 7.1.5 - Lamp replacement - 3.5.1 - Recognition of the door’s open and closed positions CE Declaration of Conformity of GD0 Components - 3.5.2 - Testing the radio transmitter CE Declaration of Conformity of Power Operated Sectional or Overhead Door 3.6 - Regulations...
Important installer and user safety instructions in these conditions can be dangerous. • If this is the first time that you install a GD0 sectional or overhead door •Keep all components of GD0 away from heat sources and open automation system we recommend that you dedicate some of your time flames;...
D) Mechanical stops E) GD0K gearmotor GD0 operates with electric power. In the event of a power failure, the gear- motor can be released using a suitable cord in order to move the door manually.
2.3.1 – GD0K Electromechanical Gearmotor GD0K is an electromechanical gearmotor consisting of a 24V direct cur- rent motor. It features a mechanical release mechanism with cord that allows you to move the door manually in the event of a power failure. The gearmotor is fixed to the ceiling with the relative mounting brackets.
• Make sure that there are no points of greater friction in the opening or closing travel of the door. GD0 must not be used to power a door that is not efficient and safe. • Make sure that the mechanical structure of the door is sturdy It cannot solve defects resulting from incorrect installation or poor enough and that there is no risk of derailing out of the guide.
Page 8
The head of the guide will have to bear all the strain of opening and closing the door; the ceil- ing-mounted brackets will have to bear all the weight of GD0. In both cases, the wear and deformations that may occur in time must be taken into consideration.
- maximum torque 55 kg. Chapter 6 “Technical Characteristics” provides the fundamental data needed to determine whether all the GD0 components are suitable for the The shape of the door and the climatic conditions (e.g. presence of strong intended application.
3.1.3 – List of cables The cables required for the installation of GD0 may vary depending on the type and quantity of devices to be installed; figure 13 shows the cables need- ed for a typical installation; no cable is supplied with GD0.
- Fixing of the gearmotor to the ceiling (see paragraph 3.3.3). 3.3.1 – Guide assembly The guide supplied with the GD0 must be assembled as follows: 1. Referring to figure 14, remove the belt tensioner device (14a); insert one end of the belt into the pulley (14b); reintroduce the belt tensioner device into the guide (14c).
The gearmotor can be rotated in three different positions 5 Using a ladder, drill the marked positions and place the brackets over the holes which have just been drilled and, using suitable screws and plugs, secure the brackets. 3.3.3 – Fixing of the gearmotor to the ceiling 6 Make sure that the guide is perfectly horizontal, then cut the excess of the brackets using a hacksaw.
9 Loosen the screws in the two mechanical stops, then place the front 3 Press the lens in order to separate the two shells. mechanical stop [O] before the carriage (Figure 33). Push the carriage hard in the closing direction and, in the reached position, tighten the screw firmly [P].
3.3.5 – KS1 key-operated selector switch (optional) To insert the shell on the bottom you need to turn the key. After you have inserted it, turn the key back to the centre position. 1 Determine the position of the selector switch; it must be installed out- doors, alongside the gate and at a height of approx.
6 Drill the holes in the wall using a hammer drill with a 6 mm bit and insert 3 Cut the rubber membrane [D] so that the cables can pass and insert it the 6 mm screw anchors. in the hole [C]. 7 Secure the bottom with the screws [C].
SAFE LED [B] shown in figure 59 flashes (on both TX and RX). The type of flashing is irrelevant, it depends on other factors; what matters is that it is The connection of the GD0 control unit to the mains must be not always off or always on.
3.5.1 – Recognition of the door’s open and closed positions Button T1 “OPEN” command The opening and closing positions of the door must be recognised by the Button T2 “Open partially” command control unit. In this phase, the door stroke from the mechanical closing stop to the mechanical opening stop is detected.
56), analysis of hazards and solutions adopted, manufacturer’s decla- 1 Make sure that the provisions contained in chapter 1 “WARN- ration of conformity of all the devices installed. For GD0 use Annexe 1 “EC INGS” have been carefully observed.
Press buttons T1 and T2 and hold them down for at least 5s 5.2 – OPTIONAL ACCESSORIES Release T1 and T2 In addition to the devices featured in GD0, other ones are available as Press button T1 three times optional accessories designed to enhance the automation system and All the parameters can be adjusted as required without any contraindica- improve its safety and performances.
• Mode 1: in this “mode” the radio transmitter is used to its fullest extent, i.e. all the buttons execute a pre-established command (the transmitter supplied with GD0 is memorized in Mode 1). It is obvious that in Mode 1 a radio transmitter can be used to command a single automation, i.e.: Button T1 “OPEN”...
3 Press the button on the NEW radio transmitter once slowly. At this point the NEW radio transmitter will be recognized by the control unit and will assume the characteristics of the OLD one. If there are other transmitters to be memorized, repeat all the steps above for each new transmitter.
5.6 – DIAGNOSTICS AND SIGNALS A few devices issue special signals that allow you to recognize the operat- ing status or possible malfunctions. 5.6.1 – Photocells The photocells are equipped with a “SAFE” LED [A] (Figure 74) that allows you to check the operating status at any time. TABLE 11 “SAFE”...
5.6.3 – Control Unit On the control unit there is a set of LED’s each of which can give special indications both during normal operation and in case of malfunctions. TABLE 13 LED OK [A] Status Action Malfunction Make sure there is power supply; check to see if there are blown fuses;...
STEP 6 The product GDX... is produced by Nice S.p.a. (TV) I. Mhouse is a commercial trademark owned by Nice S.p.a. Nice S.p.a., in order to improve its products, reserves the right to modify their technical characteristics at any time without prior notice. In any case, the manufacturer guarantees their functionality and fitness for the intended purposes.
Page 25
Power supply/contacts The device can only be connected to the “OPEN” input terminals 3-4 and 5-6 “STOP” of the MHOUSE automation control units to which the command signals are sent and draws the power supply for night lighting. Operating ambient temperature -20 ÷...
Page 26
TX4 transmitters DESCRIPTION DATA Type Radio transmitters for remote control of automatic sectional and overhead doors Adopted technology AM OOK coded modulation of radio carrier Frequency 433.92 Mhz Coding Rolling code with 64 Bit code (18 billion million combinations) Buttons 4, each button sends a command and can be used for the different controls of the same control unit or to control different control units.
The gearmotor is equipped with a mechanical system which allows the The radio transmitter is ready for use and the four buttons have the fol- door to be opened and closed manually (i.e. as if GD0 were not present). lowing functions: The manual operation must be resorted to in case o power failures or sys- tem malfunctions.
7.1.5 – Lamp replacement Before proceeding, disconnect GD0 from the power supply. 1 Unscrewing screw [A] and pushing button [B], open the lid. 2 Push the lamp up and rotate to remove. Insert a new 12V / 10W lamp...
Declaration in accordance with the Directives: 1999/5/EC (R&TTE), 2006/95/EC (LVD); 2004/108/EC (EMC); 2006/42/EC (MD) GD0 is produced by NICE S.p.a. (TV) I; MHOUSE is a commercial trademark owned by Nice S.p.a Note - The contents of this declaration correspond to declarations in the official document deposited at the registered offices of Nice S.p.a. and in particular to the last revision available before printing this manual.
Page 30
DICHIARACTION CE OF CONFORMITY According to Directive 2006/42/CE, ANNEXE II, part A (CE declaration of conformity for machines) This document must be printed in the official language of the country where the product is installed. The undersigned / Company (company name of the person responsible for commissioning of the power-operated sectional or up-and-over door) (address) Declares under his/her sole responsibility that: ❏...
Page 32
Mhouse is a commercial trademark owned by Nice S.p.a. Nice S.p.a. Via Pezza Alta, 13 - Z.I. Rustignè 31046 Oderzo (TV), Italia Tel. +39 0422 20 21 09 Fax +39 0422 85 25 82...