Scalance Xb005 - Siemens SCALANCE XB-000 Operating Instructions Manual

Hide thumbs Also See for SCALANCE XB-000:
Table of Contents

Advertisement

7.4

SCALANCE XB005

Table 7- 4
Technical specifications of the SCALANCE XB005
Technical specifications
Order number
SCALANCE XB005
Attachment to Industrial Ethernet
Quantity
Design
Properties
Transmission rate
Permitted cable lengths (Industrial
Ethernet)
0 to 55 m
0 to 85 m
0 to 100 m
Electrical data
Power supply
Current consumption
Effective power loss
Overvoltage protection at input
Permitted ambient conditions
Ambient temperature
Relative humidity
Operating altitude
SCALANCE XB-000
Operating Instructions, 12/2015, A2B00077300-06
6GK5 005-0BA00-1AB2
5
RJ-45 jacks with MDI-X pinning
Half / full duplex
10/100 Mbps
Alternative combinations per length range
Max. 55 m IE TP Torsion Cable with IE FC RJ45 Plug 180
Max. 45 m IE TP Torsion Cable with IE FC RJ45 + 10 m TP Cord via
IE FC RJ45 Outlet
Max. 85 m IE FC TP Marine/Trailing Cable with IE FC RJ45 Plug 180
Max. 75 m IE FC TP Marine/Trailing Cable + 10 m TP Cord via
IE FC RJ45 Outlet
Max. 100 m IE FC TP Standard Cable with IE FC RJ45 Plug 180
Max. 90 m IE FC TP Standard Cable + 10 m TP Cord via IE FC RJ45 Outlet
Rated voltage
Voltage range
Design
Typically, 24 VAC
Typically 24 VDC
Typically, 24 VAC
Typically 24 VDC
During operation
During storage
During transportation
During operation
During operation
Technical specifications
7.4 SCALANCE XB005
24 VAC, 50/60 Hz
1)
24 VDC
19.2 to 28.8 VAC/VDC Safety Extra Low
Voltage (SELV)
3-terminal plug-in block
150 mA
65 mA
3.6 VA
1.6 W
PTC resettable fuse (0.5 A / 60 V)
-10 ℃ to +60 ℃
-40 ℃ to +80 ℃
-40 ℃ to +80 ℃
≤ 95 % no condensation
≤ 2,000 m above sea level at max. 56 ℃
ambient temperature
≤ 3,000 m above sea level at max. 50 ℃
ambient temperature
57

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCALANCE XB-000 and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF