IMPORTANT: No more than four dryers should be
connected to one main common duct.
The illustration below shows the minimum cross-sectional
area for multiple dryer round or square venting. These figures
must be increased if the main duct run from the last dryer to
where it exhausts to the outdoors is longer than 12 feet (3.656
meters) or has more than one elbow in it.
A = 4-inch (10.2 cm)
B = 12 feet (3.656 meters)
NOTE 1 Opening from combustible materials must be 2-inches (5.08 cm)
larger than the duct (all the way around). The duct must be centered
within this opening.
NOTE 2 Distance should be 2 times the diameter of the duct to the nearest
obstruction.
Multiple Dryer Venting with 4-Inch (10.2 cm) Diameter
220 cfm (6.23 cmm) Exhaust Connections at Common Duct
NUMBER OF DRYERS
SQ IN
MINIMUM CROSS-
SECTIONAL AREA
SQ CM
IN
MINIMUM ROUND
DUCT DIAMETER
CM
Electrical Information ________________
Electrical Requirements
All electrical connections must be made by a properly licensed
and competent electrician. This is to ensure that the electrical
installation is adequate and conforms to local, state, and
national regulations or codes of the country of origin. In the
absence of such codes, all electrical connections, materials,
and workmanship must conform to the applicable
requirements of the National Electrical Code ANSI/NFPA NO.
70-LATEST EDITION or in Canada, the Canadian Electrical
Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
IMPORTANT: Failure to comply with these codes or
ordinances, and/or the requirements stipulated in this
manual can result in personal injury or component failure.
NOTE: Component failure due to improper installation will
void the warranty.
113279- 7
4
3
2
1
80
80
54
30
516.1
516.1
348.4
193.55
10
10
8
6
25.4
25.4
20.32
15.24
www.adclaundry.com
Each dryer should be connected to an independently
protected branch circuit. The dryer must be connected with
copper wire only. Do not use aluminum wire, which could
cause a fire hazard. The copper conductor wire/cable must
be of proper ampacity and insulation in accordance with
electric codes for making all service connections.
NOTE: The use of aluminum wire will void the warranty.
An individual ground circuit must be provided to each
dryer, do not daisy chain.
Component failure due to improper voltage application will
void the warranty.
The manufacturer reserves the right to make changes in
specifications at any time without notice or obligation.
IMPORTANT: A separate protected circuit must be
provided to each dryer.
The dryer must be connected to the electric supply shown
on the data label. In the case of 208 VAC or 240 VAC, the
supply voltage must match the electric service
specifications of the data label exactly.
The wire size must be properly sized to handle the related
current.
WARNING
!
208 VAC and 240 VAC are not the same. Any damage
done to dryer components due to improper voltage
connections will automatically void the warranty.
WARNING
!
Dryers built for use with a voltage between 200 and
240 must verify the input voltage during installation.
If the nominal voltage is outside of the medium
tolerances shown on the diagram below, adjust the
autotransformer, located near the burner assembly.
To adjust the autotransformer wiring, place the red
wire on the appropriate tap (HIGH, MED, LOW) of the
autotransformer. For additional wiring details, refer
to the electrical diagram located on the inside of the
control panel.
LINE VOLTAGE
TERM
HIGH
MED
LOW
(Gas Models Only)
50 Hz
60 Hz
260
283
226
249
239
260
208
230
217
236
189
208
11