Installing Rpms And Line Cards - Dell Networking C9010 Installation Manual

Hide thumbs Also See for Networking C9010:
Table of Contents

Advertisement

1.
Slide the first fan module into fan slot 0 by pushing the handle (item 1 in Figure 19) forward into the
uppermost fan slot (item 2 in Figure 19).
2.
Gently push the front of the module until it clicks into place. The fan module should be flush with the
chassis.
3.
Repeat Steps 1 and 2 to install the second and third fan modules in fan slots 1 and 2.
4.
To remove a fan module, press the orange button on the handle and pull out the module.
Figure 19. Installing a Fan Module
NOTE: The switch does not have an air filter; ensure that you regularly clean the installation site and
the chassis.
NOTE: The fan module LED remains green when the chassis is powered up and the fan module is
functioning properly.

Installing RPMs and Line Cards

The C9010 chassis supports up to ten line cards and two route processor modules.
WARNING: Always wear an ESD-preventive wrist or foot-heel ground strap when handling an
RPM or a line card. Always place RPMs and line cards on an antistatic surface or in an antistatic
bag when not in use or when carrying them. ESD damage can occur when components are
mishandled. Do not use the ejector handle to carry an RPM or line card.
28