Panasonic VL-SVN511 series Installation Manual

Panasonic VL-SVN511 series Installation Manual

Video intercom system/main monitor station
Hide thumbs Also See for VL-SVN511 series:

Advertisement

Model Name
Model No.
R This guide is for use with the above 2 models.
R The VL-SVN511 models composition consists of VL-MVN511 and VL-V522L.
R The Installation Guide in Indonesian and Thai can be accessed from the following site:
http://panasonic.net/pcc/support/intercom/svn511/
R Door station is described as "doorphone" and Main monitor station is described as "main
monitor" in this guide.
R In this guide, the suffix of each model number (e.g., the "BX" in "VL-SVN511BX") is omitted
unless necessary.
Note to the installer
R Before attempting to connect or operate this product, please read the label on the rear of
the doorphone and the main monitor.
R Please read this guide carefully, and install the product safely and correctly by following
the instructions. Carefully read the information found in the section titled "For your
safety" in particular.
R Only use attachments/accessories specified by the manufacturer.
R The installation shall be carried out in accordance with all applicable installation rules.
R Panasonic assumes no responsibility for injuries or property damage resulting from
failures arising out of improper installation or operation inconsistent with this guide.
Additionally, any resulting malfunction will not be covered under the warranty.
R After installation, make sure to leave this guide with the customer.
Video Intercom System
VL-SVN511 Series
VL-V522L
Door station

Installation Guide

Main Monitor Station
VL-MVN511
VL-MVN511
Main monitor station

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic VL-SVN511 series

  • Page 1: Installation Guide

    R Only use attachments/accessories specified by the manufacturer. R The installation shall be carried out in accordance with all applicable installation rules. R Panasonic assumes no responsibility for injuries or property damage resulting from failures arising out of improper installation or operation inconsistent with this guide.
  • Page 2: For Your Safety

    cause electric shock, short circuits, or fire. For your safety Contact an authorised service centre for repairs. R When existing chime wires are used, it is possible that they contain AC voltage. To prevent severe injury and loss of life/property, Contact an authorised service centre.
  • Page 3: Supplied Accessories For Installation

    Supplied accessories for installation For the doorphone Screw ´ 2 (3.8 mm ´ 20 mm) For the main monitor Relay box and related items Cable binder ´ 1 Cable binder ´ 1 Mounting bracket ´ 1 Screw ´ 2 Relay box ´ 1 Screw ´...
  • Page 4: Precautions For Installation

    Precautions for installation To avoid malfunction or communication disturbances, do not install the doorphone or the main monitor in the following locations: – Places where vibration or any other kind of impact occurs. – Places where echoing is frequent. – Places near a high concentration of dust, hydrogen sulphide, ammonia, sulphur, or noxious fumes. For the doorphone R If a strong light is shining on the doorphone, the visitor’s face may not be distinguishable.
  • Page 5: Wiring Schematic Diagram

    Wiring schematic diagram Set up correctly according to the following wiring schematic diagram and "Wire type and length". R For information, such as order numbers, about optional devices that can be connected to, refer to the "Additional/replacement accessories" section in the Operating Instructions. DOORPHONE 1 *1,*5 DOORPHONE 2 *1,*5...
  • Page 6 Wire type and length Wire type Wiring run Diameter Length (Max.) ø 0.65 mm 22 AWG 100 m Main monitor – Doorphone ø 1.0 mm 18 AWG 130 m (including lobby station) ø 0.5 mm CAT 5 50 m ø 0.65 mm 22 AWG 10 m Main monitor –...
  • Page 7 n Connecting an optional lobby station Lobby station (VL-V590) MAIN MONITOR <Rear view> RELAY BOX *1 <Rear view> Electric lock 30 V AC/ 24V DC Power supply NP: Non-polarised <Connecting an optional lobby station for apartment complexes> R Be sure to perform the following to ensure proper operation –...
  • Page 8: Doorphone Installation Position

    Doorphone installation position Installation position of the doorphone and camera range Views when the camera is facing forwards at 0° (default). R Example: Installation height is 1450 mm (standard position). (Units: mm) A view when looking from above A Image range B Approx. 66° C Centre of doorphone D Approx. 1450 E Approx. 500 F Approx.
  • Page 9: Installing The Doorphone

    Attach the mounting base (A) to the wall Installing the doorphone securely using the wood screws (B) (accessory). Important: R Install the mounting base on a vertical flat wall. R On the bottom surface of the doorphone and the R Before drilling, refer to “Precautions for mounting base, there are holes to allow water to installation”...
  • Page 10 Examples of camera angle Mount the doorphone to the mounting base. Fasten the screw, then close the Facing forwards Facing upwards screw cover (C). Facing right Facing upper right R The angle can also be adjusted to the left or upper left.
  • Page 11: Installing The Power Supply Unit (Vl-Mvn511 Models Only)

    Power supply unit (with cable covers Installing the power supply removed) Top view Bottom view unit (VL-MVN511 models only) About the installation location R The device must be installed inside an electrical panel or cabinet. R A readily accessible disconnect device shall be L AC cable binder hole incorporated external to the equipment.
  • Page 12: Installing The Power Supply Unit (Vl-Svn511 Models Only)

    Power supply unit (with cable cover removed) Installing the power supply Top view Bottom view unit (VL-SVN511 models only) About the installation location R The AC cable plug is used as the main disconnect device. Ensure that the power outlet K DC cable binder hole is installed near the product and is easily accessible.
  • Page 13: Main Monitor Installation Position

    Main monitor installation Installing the main monitor position Attach the mounting bracket (A) to the wall securely. About the installation position of the main R Install the mounting bracket on a vertical flat monitor and mounting bracket wall (B). R Place the main monitor in a location that your eyes are the same height as the centre of the display.
  • Page 14: Installing The Relay Box

    2-2 How to make wiring connections While pressing on the button (F) with a Installing the relay box pointed object such as a screwdriver, insert the wire into the terminal connector (G). (To Wiring when you connect the main monitor cable disconnect a wire, while pressing on the and electric lock using relay box Button (F), pull out the wire.)
  • Page 15 Notes...
  • Page 16 1-62, 4-chome, Minoshima, Hakata-ku, Fukuoka 812-8531, Japan http://www.panasonic.com/ © Panasonic System Networks Co., Ltd. 2015 PNQX7569ZA C0915MM0...