I/O Devices Window; Added Supported Devices - Yamaha CL5 Supplementary Manual

Hide thumbs Also See for CL5:
Table of Contents

Advertisement

I/O Devices window

Added supported devices

The RSio64-D is now supported. You can operate the RSio64-D in the I/O Devices window.
I/O Devices window (I/O page)
 RSio64-D display
1
2
6
7
1
CARD NAME
This indicates the names of the cards installed in slots 1 to 4. If nothing is installed,
"----" will appear.
2
IN/OUT PORT
This indicates the number of input and output ports for the cards installed in slots 1 to
4. If no card is installed, "--" will appear.
3
4
5
B
8
9
0
A
3
SLOT 1 - 4 LOCK indicators
This indicates the word clock status for slots 1 to 4. If the word clock is operating
normally, this indicator will be green.
Off
There is no card in the slot. Or, an unsupported card is in the slot.
Indicates that a clock synchronized with the clock source selected with the
[WORD CLOCK] select key is being input from the card. If an external device is
Green (On)
connected to the corresponding slot, input/output is occurring properly between
LOCK
that device and the RSio64-D. If the sampling frequency is close, this status may
be displayed even if not synchronized.
Green
A valid clock is being input from the card, but is not synchronized with the clock
(Flashing)
source selected with the [WORD CLOCK] select key. If an external device is
SYNC
connected to the corresponding slot, input/output cannot occur correctly between
ERROR
that device and the RSio64-D. Turn SRC ON for correct input/output.
A valid clock is not being input from the card. If an external device is connected to
Red (On)
the corresponding slot, input/output cannot occur correctly between that device
UNLOCK
and the RSio64-D.
Red
The frequency of the clock source selected with the [WORD CLOCK] select key is
(Flashing)
outside of the operating frequency range for the card inserted in the slot. Either
WRONG
set the frequency of the clock source within the operating range for the card, or
WORD
turn [SRC] ON. For an analog card, if you turn [SRC] ON, the frequency is set to
CLOCK
the 48kHz built into the RSio64-D.
4
SLOT 1 - 4 SRC indicators
Indicate the Sampling Rate Converter (SRC) status for slots 1 to 4.
Off
SRC is off.
SRC is on, and the clock selected with the SRC WCLK DIP switches on the
Green (On)
RSio64-D is being input correctly.
SRC is on, but an appropriate clock is not being input. The clock selected with the
Red (On)
SRC WCLK DIP switches on the RSio64-D is either not being input or is not
within the operating range. Either turn SRC off, or change the DIP switch settings.
NOTE
Use the SRC WCLK DIP switches on the RSio64-D to set the SRC clock sent to the Mini-YGDAI
card inserted in the slot.
5
SLOT 1 to 4 SRC buttons
Used to turn SRC on/off at both IN and OUT for each slot.
6
WORD CLOCK select button
Used to select the word clock source for the RSio64-D.
• WORD CLOCK WCLK IN indicator
• WORD CLOCK SLOT1 1/2 indicator
• WORD CLOCK DANTE indicator
5
I/O Devices window
V3.1 Supplementary Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl1Cl3