Control interface for external devices

 TALLY/GPI
TALLY IN 1 to TALLY IN 5 are contact input ports which are used to light the unit's
tally indicators (above the CAMERA STATUS/SELECTION buttons).
The tally lamps light with contact input.
GPI IN 1 to GPI IN 4 are contact input ports which are used to control the unit from
an external source.
GPI OUT 1 to GPI OUT 4 are open output ports which are used to output the
statuses to an external source.
Pin No.
1
2
3
4
5
6
7
8
Example of GPI OUT connections
Ensure that the conditions given below are satisfied.
Dielectric strength: Max. DC 24 V
Current:
Max. 50 mA
AW-RP50
GPI OUT
(Max. current: 50 mA)
GND
: The selection statuses (CAMERA STATUS/SELECTION buttons 1 to 5) of the remote cameras can be monitored at
GPI OUT 1 to GPI OUT 3.
CAMERA STATUS/SELECTION
button
1
2
3
4
5
Signal
TALLY IN 1
9
TALLY IN 2
TALLY IN 3
10
TALLY IN 4
TALLY IN 5
11
GND
GPI IN 1
12
GPI IN 2
GPI IN 3
13
GPI IN 4
GPI OUT 1
14
GPI OUT 2
GPI OUT 3
15
GPI OUT 4
NC
(Max. voltage: 24 V)
LED
Remote camera
selection 0
(GPI OUT 1)
On
Off
On
Off
On
Description of signal
CAM1 tally input
CAM2 tally input
CAM3 tally input
CAM4 tally input
CAM5 tally input
Ground
Preset input 1
Preset input 2
Preset input 3
Panel lock
Remote camera selection 0
Remote camera selection 1
Remote camera selection 2
Alarm
Not used
Example of TALLY IN and GPI IN connections
Provide contact inputs.
AW-RP50
+3.3 V
Remote camera
selection 1
(GPI OUT 2)
Off
On
On
Off
Off
37 (E)
(D-sub 15-pin, female, inch thread)
8
15
Operation
Contact input
Contact input
Open collector output
TALLY IN
GPI IN
GND
Remote camera
selection 2
(GPI OUT 3)
Off
Off
Off
On
On
1