MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A ZERO
CLEARANCE FIREPLACE OR WITH AN OPTIONAL
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the
gas supplier.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is in-
stalled. Provisions for adequate combustion and ventilation air must be provided. Refer to
section " Producing Adequate Ventilation" page 35.
This appliance may be installed in an aftermarket, permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appli-
ance is not convertible for use with other gases.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Manufacturer: NEW BUCK CORPORATION
P.O. Box 69
8000 Highway 226 South
Spruce Pine, NC 28777
MODEL 34
This appliance is intended for supplemental heating.
SURROUND.
Revised December 2006

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 34 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for New Buck Corporation 34

  • Page 1 This appliance is only for use with the type of gas indicated on the rating plate. This appli- ance is not convertible for use with other gases. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. Manufacturer: NEW BUCK CORPORATION P.O. Box 69 8000 Highway 226 South Spruce Pine, NC 28777 MODEL 34 This appliance is intended for supplemental heating.
  • Page 3: Table Of Contents

    SECTION III: Solid Fuel Burning Fireplace Installation (FP)... 26 SECTION IV: Wooden Surround Installation (WS) ... 28 SECTION V: Zero Clearance (ZC) ... 30 SECTION VI: Installation-After Market Mobile Home... 34 SECTION VII: Producing Adequate Ventilation ... 35 Ventilation Air From Inside... 37 Ventilation Air Outdoors ...
  • Page 5: Safety Information Warnings

    SAFETY INFORMATION WARNINGS IMPORTANT: READ THIS OWNER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING TO ASSEMBLE, OPERATE, OR SERVICE THE APPLIANCE. IMPROPER USE OF THESE LOGS CAN CAUSE SERIOUS INJURY OR DEATH FROM BURNS, FIRE, EXPLOSION, AND CARBON MONOXIDE POISONING. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea.
  • Page 6 5. If this heater is used with propane gas, do not place propane supply tank (s) inside any structure. 6. What To Do IF You Smell Gas: Shut off gas supply. - Do not try to light any appliance. - Do not touch any electrical switch; do not use any phone in your building. - Immediately call your gas supplier from a neighbor’s phone.
  • Page 7 21. All heater screens must be kept closed when operating the gas logs. ”WARNING: Failure to keep the primary air opening (s) of the burner (s) clean may result in sooting and property damage.” 23. Do not use this heater for burning trash or cooking. Never place matches, paper, garbage, or any other material on top of logs or into the flames.
  • Page 8: Section Ii: Fireplace Preparation/Solid Fuel Burning Fireplace (Fp)

    SECTION II FIREPLACE PREPARATION The fireplace needs to be prepared before installing the heater. A. Turn off the gas supply to the fireplace. WARNING: BEFORE INSTALLING IN A SOLID-FUEL BURNING FIREPLACE, THE CHIMNEY FLUE AND FIREBOX MUST BE CLEANED OF SOOT, CREOSOTE, ASHES, AND LOOSE PAINT BY A QUALIFIED CHIMNEY CLEANER.
  • Page 9: Installation And Clearances

    INSTALLATION AND CLEARANCES To ensure a safe installation into a masonry or factory built fireplace, the following instructions must be carefully followed: (1) Sidewall Clearances: Clearance from the side of the fireplace opening to any adjacent combustible wall should not be less than: right side 7", left side 7". (2) Ceiling Clearances: The ceiling height should not be less than 24"...
  • Page 10: Placement Of Logs

    CR3329 CERAMIC LOG SET PLACEMENT, FOR MODEL 34 (1-R) (1-L) WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
  • Page 11 EMBER STOVE LOG SET PLACEMENT FOR MODEL 34 WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. WARNING: POSITIONING OF LOGS IS VERY CRITICAL (SEE DIAGRAM ABOVE).
  • Page 12: Gas Pressure Check

    GAS PRESSURE CHECK Check the inlet pressure to the burner to ensure that it is as shown in the table below. GAS PRESSURE CHECK NOTE: The pressure check point is located on the right side of the valve facing burner, for SIT Millivolt, and the left side for SIT Modulating.
  • Page 13: Lighting Instructions - Itt Millivolt Valve

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
  • Page 14 LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on previous page. 2. Make sure the manual shutoff valve is fully closed.If equipped with thermostat set to the lowest setting. 3. Turn off all electrical power to the appliance. 4. Open access panel door located at bottom front of the appliance. 5.
  • Page 15: Pilot Burner

    • If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. IGNITOR ELECTRODE THERMO-PILE THERMO-COUPLE 12. Turn control knob counterclockwise toggle switch to the “ON” position. The main burner should light. 13.
  • Page 16: Manual Lighting Procedure

    THERMOSTAT CONTROL OPERATION • This valve operates off of millivolts produced by the generator. You may choose to use an optional Wall Thermostat or Remote control. If so, see page 22 for wiring diagram. MANUAL LIGHTING PROCEDURE If the pilot cannot be lit with the piezo, it can be manually lit with the use of a paper match and a lighter rod.
  • Page 17: For Your Safety Read Before Lighting

    LIGHTING INSTRUCTION FOR YOUR SAFETY READ BEFORE LIGHTING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.” A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
  • Page 18 LIGHTING INSTRUCTION 1. STOP! Read the safety information on preceding page 15. 2. Make sure manual shutoff valve is fully closed. 3. Turn off all electrical power to the appliance. 4. Open access panel door located at bottom front of the appliance. 5.
  • Page 19: To Turn Off Gas To Appliance

    11. Turn gas control knob counterclockwise to “ON” position. Continue to turn the gas control knob counterclockwise to your desired setting. 12. Close access panel door. 13. Turn on all electrical power to the appliance. CAUTION DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE MANUAL SHUTOFF VALVE.
  • Page 20 THERMOSTAT CONTROL OPERATION The thermostat control on this heater differs from standard thermostats. Standard thermostats simply turn the burner on and off. The thermostat used on this heater senses the room temperature and adjusts the amount of gas flow to the burner. This will increase or decrease the flame height.
  • Page 21: Operating Instructions

    OPERATING INSTRUCTIONS Before operating this appliance, proceed through the following checklist. 1. Read and understand these instructions before operating this appliance. 2. Check that there are no gas leaks. If you smell gas do not attempt to light this appliance. 3.
  • Page 22 LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on the reverse side of this label (page 19). 2. Make sure manual shutoff valve is fully closed. If equipped with thermostat, set to the low- est setting. 3. Turn off all electrical power to the appliance. 4.
  • Page 23 * If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 11. Turn control knob counterclockwise 12. If using unit without wall thermostat place Auto/Off/Manual switch into the manual position.
  • Page 24 MANUAL LIGHTING PROCEDURE If the pilot cannot be lit with the piezo, it can be manually lit with the use of a paper match and a lighter rod. Open access panel door located at bottom front of the appliance. Place the match in the holder and light. With the left hand, turn the control knob counterclockwise (15) seconds.
  • Page 25: Flame Check

    A periodic check of the flames should be made. The pilot flame should always be present when the gas logs are in operation. See Figure 4. Rear Flames: The flames at the rear or at either side of the top log should be very similar, yellow in color, and should be about 3"...
  • Page 26: Wiring Diagram

    MOTOR GREEN POWER CORD WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE APPLIANCE WARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR THE APPLIANCE.
  • Page 27 SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. NOTE: #PESBRO84 Blower may be used with Model FP-42-ZC. Rating: 120 volts/60HZ/1.1 Amps. See Figure 17, page 34 for wiring diagram. NOTE: For convenience, allow licensed electrician to install properly grounded 3-plug receptacle near unit.
  • Page 28: Section Iii: Solid Fuel Burning Fireplace Installation (Fp)

    INSTALLATION MODEL 34 (FP) IN SOLID FUEL BURNING FIREPLACES (1) The Model FP-34 may be installed in a masonry fireplace. The minimum fireplace dimension must be 24" high, 29-1/2" wide, and 12" deep. (2) For minimum dimensions for the sidewall and mantel, see Figure 6.
  • Page 29 Set the top (long) trim panel in place on top of unit. The panel should be flat against the outside face of the fireplace, and standing vertically. Mark along the lower edge of the trim panel with a pencil to make reference line for mounting. NOTE: If used in installation trim panels or surrounds shall not seal ventilation openings in the fireplace.
  • Page 30: Section Iv: Wooden Surround Installation (Ws)

    INSTALLATION OF MODEL 34 (WS) OPTIONAL WOODEN SURROUND (KIT#PAKDFP34) NOTE: See page 26, figure 6 for clearances. When choosing the right location for your heater and surround (mantel) keep the following in mind: NOTE: Due to high temperatures, this heater should be located out of traffic areas and away from furniture and draperies.
  • Page 31 STEP 10: Place top on to the surround (mantel), flush with the back and equal on each end. Secure both ends and middle with screws. EXPLODED VIEW OF MODEL 34 SURROUND KIT# PAKDFP34 AS VIEWED FROM BACK OF SURROUND (MANTEL)
  • Page 32: Gas Line

    MODEL 34 (ZC) ZERO CLEARANCE INSTALLATION The installation must conform with local codes ,or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA54. This appliance may be installed in an After-Market where not prohibited by state or local codes.
  • Page 33 GAS LINE 3-1/4" 4-1/4" WARNING: Installation and repairs should be performed by a qualified service person. The appliance should be inspected before use and at least annually by a professional ser- vice person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc.
  • Page 34 FIREPLACE CLEARANCES (ZC) The fireplace may be placed directly on a combustible floor, against a combustible wall at marked clear- ances, or on a raised wooden platform. If the fireplace is to be installed on a raised wooden platform, the platform must be a continuous level surface.
  • Page 35 FINISHING YOUR FIREPLACE (ZC) There is a wide variety of finishing material available for your fireplace from formal wall treatments with marble and mantels, to rustic wood paneling, stone or brick. Non- combustible materials used installation such as slate, tile, marble, etc. must be at least 1/2"...
  • Page 36: Section Vi: Installation-After Market Mobile Home

    AFTER MARKET MOBILE HOME NOTE: See “Producing Adequate Ventilation” page 35 THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET*, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME, WHERE NOT PROHIBITED BY LOCAL CODES. *After Market: Completion of sale, not for the purpose of resale from the manufacturer. THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE.
  • Page 37: Section Vii: Producing Adequate Ventilation

    PRODUCING ADEQUATE VENTILATION This section is for residential or manufactured (mobile) installation “This heater shall not be installed in a confined space or unusually tight construction unless pro- visions are adequate combustion and ventilation air.” The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 BTU per hour (4.8m per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a...
  • Page 38 1. Determine the volume of the space (length x width x height). Length x Width x Height =_________cu.ft.(volume of space) EXAMPLE: 20 ft.(Length) x 16 ft.(Width) x 8 ft.(ceiling Height)= 2560 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
  • Page 39: Ventilation Air From Inside Building

    VENTILATION AIR VENTILATION AIR FROM INSIDE BUILDING This fresh air would come from an adjoining unconfined space. When venting to an adjoining space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces.
  • Page 40: Ventilation Air From Outdoors

    THIS APPLIANCE MUST HAVE FRESH AIR FOR PROPER OPERATION. IF NOT, POOR FUEL COMBUSTION COULD RESULT. INSTRUCTIONS TO ENSURE PROPER FRESH AIR FOR THIS AND OTHER FUEL- BURNING APPLIANCES IN YOUR HOME. VENTILATION AIR FROM OUTDOORS Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12"...
  • Page 41: Important Safeguards

    IMPORTANT SAFEGUARDS Although your gas logs are very realistic in appearance, it is not a real burning fireplace and must not be used for burning rejected material. • To avoid irreparable damage to the heater or personal injury, matches, paper, garbage, or any other material must not be placed or thrown on top of the logs or into the flames.
  • Page 42: Troubleshooting

    TURN OFF, UNPLUG HEATER AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE PERSON SHOULD SERVICE AND REPAIR HEATER. NEVER USE A WIRE, NEEDLE, OR SIMILAR OBJECT TO CLEAN ODS/ PILOT. THIS CAN DAMAGE ODS/PILOT. OBSERVED PROBLEM Igniter button pressed No spark at ODS/Pilot OBSERVED PROBLEM...
  • Page 43 OBSERVED PROBLEM ODS/PILOT lights but flame goes out when control knob is released 4. Air in gas lines when installed 5. Depleted gas supply 6. ODS/Pilot is clogged 7. Gas regulator setting is not correct POSSIBLE PROBLEM 1. Control knob is not fully pressed in 2.
  • Page 44 OBSERVED PROBLEM Burner does not light after ODS/ Pilot is lit Delayed ignition of burner Burner backfiring during combustion Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit POSSIBLE CAUSE 1. Burner orifice is clogged 2.
  • Page 45 IF YOU SMELL GAS: * SHUT OFF GAS SUPPLY * DO NOT TRY TO LIGHT APPLIANCE * DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY PHONE IN YOUR BUILDING * IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR’S PHONE.
  • Page 46: Service And Repair Parts

    Please contact your local dealer or distributor when ordering . If one is not available, you may contact. SERVICING REPAIR PARTS New Buck Corporation 8000 Highway 226 South Spruce Pine, NC 28777...
  • Page 47: Replacement Parts

    KEY# PART DESCRIPTION Carling Switch Female Terminals Piezo Igniter Piezo 14" Igniter Wire Pilot (NAT.) Copreci Pilot (LP) Copreci Pilot Tube 1/4" 1/8" x 1/4" Compression Adapter Regulator (LP) Maxitrol Regulator (NAT.) Maxitrol Pilot Tube 1/4" 3/8" x 3/8" Elbow (Brass) Thermo-pile Jumper Wire 6"...
  • Page 48 PILOT...
  • Page 49 SIT MODULATING OR MANUAL VALVE KEY# PART DESCRIPTION Pilot (NAT.) Copreci Pilot (LP) Copreci Thermocouple (Copreci) Pilot Tube 1/4" Pilot Tube 1/4" Burner Tube 3/8" Pilot Regulator (LP) Maxitrol Pilot Regulator (NAT.) Maxitrol Burner Tube Orifice Holder Orifice Valve (LP) MOD. SIT Valve (NAT.) MOD.
  • Page 51 KEY# PART DESCRIPTION 820 MV. S.I.T. VALVE GENERATOR BURNER TUBE O.D.S PILOT (L.P.) O.P. ASSEMBLY O.D.S PILOT (NAT.) O.P. ASSEMBLY THERMO-COUPLE 2"-3/8" BLACKIRON NIPPLE BURNER SUPPLY LINE ELBOW 21" PILOT TUBE 3/16" ORIFICE ORIFICE HOLDER 3/8" NUT & SLEEVE PIEZO STRIKER CARLING SWITCH (AUTO/OFF/MANUAL) 12"...
  • Page 52 SIT MILLIVOLT...
  • Page 53 REPLACEMENT PARTS FOR EMBER STOVE BASE (ESB) A parts list with exploded view follows. Always include correct name, part number, and model number of the heater when ordering service parts. KEY# O.D.S. PILOT (L.P.) O.P. ASSEMBLY O.D.S. PILOT (NAT) O.P. ASSEMBLY GENERATOR ASSEMBLY PILOT TUBE 3/16"...
  • Page 54 Please contact your local dealer or distributor when ordering . If one is not available, you may contact. REPAIR PARTS New Buck Corporation 8000 Highway 226 South Spruce Pine, NC 28777 SIT MILLIVOLT...
  • Page 55: Limited Warranty

    NEW BUCK CORPORATION We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We offer no other warranty, expressed or implied. LIMITED WARRANTY VENT-FREE GAS LOG HEATER New Buck warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated, and maintained in accordance with all applicable instructions.

Table of Contents

Save PDF