Sanyo Plc-WXU300 Service Manual page 44

Hide thumbs Also See for Plc-WXU300:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
16 DIMMER_CTRL_LEVEL15
17
DIMMER_AVERAGE_POINT
18 DIMMER_AVERAGE_DATA
19 DIMMER_LEVEL_AUTO
0 DIMMER_LEVEL_NORMAL Normal Dimmer Level
1 DIMMER_LEVEL_ECO
 Lamp check enable
3 VOLTAGE_LEVEL
4 DIMMER_LEVEL_HIGH
Group
Projector Warning log
220
0 Warning Log_1
.. ..
49 Warning Log_50
50 Warning Log Reset
Group
FAN control
250
0 FAN1 MIN ADJUST (DAC)
1 FAN1 MAX ADJUST (DAC)
 FAN MIN ADJUST (DAC)
3 FAN MAX ADJUST (DAC)
4 FAN3 MIN ADJUST (DAC)
5 FAN3 MAX ADJUST (DAC)
Group
Filter detection setting
251
0 Filter Warning Calibration
1 Filter Warning Offset Optio-0
 Filter Warning Offset Optio-1
3 Filter Warning Offset Optio-
4 Filter Warning Offset Optio-3
5 Filter Warning Offset Optio-4
6 Filter Warning Offset Optio-5
7 Filter Warning Offset Optio-6
8 Filter Warning Offset Optio-7
9 Not Used
10 Not Used
11 Not Used
1 Not Used
13 Filter Warning Times
14 Fan-Add Filter Level 1
15 Fan-Add Filer Level 
16 Filter Warning Calibration Range
17 Filter Warning Calibration Time
18 Filter Warning Calibration Error Log
19 Filter Warning High Land Calibration Error Log
0 Fliter Warning Calibration Temp
1 Filter Warning Inclination Rpm (to 6˚C)
 Filter Warning Inclination Rpm (over 6˚C)
3 Filter Warning Add Offset Rpm
Group
Fan option
252
0 Fan Max SWITCH
1 SAFETY SWITCH
 FAN MANUAL SWITCH
3 FAN1 MANUAL VOLTAGE
4 FAN MANUAL VOLTAGE
5 FAN3 MANUAL VOLTAGE
6 FAN4 MANUAL VOLTAGE
7 FAN5 MANUAL VOLTAGE
8 FAN6-8 MANUAL DUTY
9 All Fan MaxMin Control
10 Press Data
Group
Fan tem error Setting (Memorized)
253
Function
Luminance Level 15 Data for
Dimmer: Dim Level 15 at the less
than the Value
Luminance Data Avarage Point for
Mimmer
Luminance Data Avarage Value for
Dimmer
Current Dimmer Leverl
Eco Dimmer Level
Lamp Voltage
Dimmer level High
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
0: Normal, 1: Max (13.5V)
For test purpose
0: Auto, 1: Manual
Fan Voltage (unit : 0.1V)
Effective only when Fan Maual
switch is 1
0 : Normal
1 : Lamp Max / Fan Min
 : Lamp Max / Fan Max
3 : Lamp Min / Fan Min
4 : Lamp Min / Fan Max
Initial
105
4
-
-
8
0
1
-
15
-
-
-
-
17
7
7
36
17
7
0
1731
686
3456
4139
478
51
5607
5899
3
1000
000
1

55
55
60
60
80
-
0
0
0
100
100
100
100
100
-
0
Normal
Ceiling
-44-
range
Note
0 - 55
0 - 16
-
* Read only
-
* Read only
0 - 15
0 - 15
0: Lamp Failure Detection OFF
(White 50% Back), 1 : ON (Blue
100% Back)
Unit: 8bit(Raw Data) * Read only
0 - 15
0-3767
..
0-3767
0-10
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0 - 55
0-1
0000-9999
0000-9999
0000-9999
0000-9999
0000-9999
0000-9999
0000-9999
0000-9999
0-10
0000-9999
0000-9999
0-10
0-10
0-55
0-55
-
0000-9999
0000-9999
-
0 - 1
0 - 6
0 - 1
0 - 145
0 - 145
0 - 145
0-55
0-55
0-511
0 - 4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents