8-1-5. Disassembly of the armature and the stator ... See Fig. 5.
(a) Remove housing (B).
Take out the Armature [56], Stator [57] and Brush Block Ass'y
[61] together from housing (A).
(b) The Second Pinion and Gear Set [49] can also be removed.
8-1-6. Disassembly of the power supply unit ... See Fig. 6.
(a) Remove housing (B).
(b) Loosen the two Tapping Screws (W/Flange) D4 x 16 [69]
securing the Cord Clip [68].
(c) Loosen the four Machine Screws (W/Washer) M3.5 x 6 [43] in
the Switch Ass'y [45] and remove the Cord [71] and the
Noise Suppressor [48].
* Be careful not to hitch Terminal (A) M3.5 [44] at removal
because Terminal (A) M3.5 [44] connects the Noise
Suppressor [48] to the Stator [57].
(d) Take out the Cord [71] together with the Cord Armor D8.2
[70].