INSTALLATION & SERVICING MANUAL FOR 50/70 – 70/90 – 90/120 – 120/150 – 150/200 BLUEBIRD BOILERHOUSE MODELS, GOLDBIRD KITCHEN MODELS & WHITEBIRD UTILITY ROOM MODELS 50/90 FRONT SERVICING BOILERS GOLDBIRD KITCHEN MODEL WHITEBIRD UTILITY ROOM MODEL 200/250 BLUEBIRD BOILERHOUSE MODEL 50/70 –...
Page 2
OFTEC registered technician. NI CUSTOMERS ONLY Warmflow Engineering Service division (NI) provides an excellent back-up service, operating a team of OFTEC trained engineers who can meet all the servicing, commissioning and breakdown requirements for your appliance.
The yellow H/L reset lamp will be lit when the boiler has overheated and tripped the high limit thermostat, which then needs to be manually reset. If the high limit thermostat continues to trip, contact Warmflow or your service engineer/technician. The manual reset thermostat has a cut out point of 110°C.
Components 50/90 Front Servicing Boiler WHITEBIRD THERMOSTAT THERMOSTAT POCKET GOLDBIRD CONTROL PANEL TOP CASING FLUE RING BAFFLES INSULATION SHIELD DOOR INSULATION DOOR GASKET SIDE SERVICE DOOR CASING EXTERNAL DOOR INSULATION BOILER TEST POINT INSULATION BURNER RESET BUTTON/ OPTIONAL AIR RETAINER LOCK OUT LAMP BURNER INTAKE SPIGOT...
Baffles 1.8.1 Top Servicing Boilers FRONT FRONT 70/90 & 120/150 (8 in number) 50/90 50/70 90/120, 150/200, 300, 400 & 500 (4 in number) (3 in number) have a similar arrangement heavy baffle to the bottom (12, 12, 12, 16 and 16 baffles respectively) 1.8.2 Components 50/90 Front Servicing Boiler...
(although not applicable to the Republic of Ireland). Warmflow oil fired boilers are designed to burn 28 second redwood No 1 (Kerosene Class C2) fuel or with some adjustment 35 second redwood No 1 (Gas Oil Class D). In order to comply with current building regulations only kerosene must be burned when used with low level flue or low level balanced flue.
— — The Kabin Pak comes factory fitted with a Warmflow Bluebird Boiler and insulated low level flue kit complete with a terminal guard. An adaptor is available to allow the low level flue to be extended using standard twin wall round flue.
Kabin Pak Back Outlet E x N MODEL 50-70 70-90 Slimline Kabin Pak MODEL 50-90 When installing a Slimline Kabin Pak against a wall allow 600mm to the front and rear of the appliance for servicing. Page 9...
Flue Options 3.7.1 ‘Easy Fit’ Low Level Balanced Flue Ø125 The horizontal dimension can be increased up to an additional 1200mm using a combination of long 225 MAX extension pieces (600mm) and short 175 MIN 712 MAX extension pieces (300mm). 490 MIN SEE OPTIONS 160x160...
Page 13
225 MAX DIM A FLUE PACKS A + E A + F A + C + E 900 MIN 1400 MAX 50/70, 70/90 & 90/120 MODELS ONLY PACK A DIM A FLUE PACKS 1160 A + C + F 1035 1210...
In areas of hard water a suitable water softener would also be recommended. Sealed Systems All Warmflow boilers are suitable for use on a sealed heating system. It is recommended that a CE approved pressure relief valve (PRV) set at 3 bar is fitted to the system. The industrial bluebirds can be fitted with a 4 bar PRV.
Air Vents On the system boiler an automatic air vent complete with its own check valve is fitted to the top of the boiler heat exchanger. It is recommended that an air vent is fitted at the highest point in the system. However where the pipework comes off the boiler and drops down an automatic airvent should be fitted to the top of the boiler.
Electricity Supply 220 – 240V. 1PH, 50 Hz The boiler/burner and other external electrical equipment should be wired with heat resistant cable via a fused double pole isolating switch which should be fitted with a 5 amp fuse. The appliance must be effectively earthed and all external wiring should comply with current IEE Regulations.
REMOTE LOCK-OUT IF REQUIRED FAN HOUSING BROWN GREEN/YELLOW Installation of Warmflow Optional Programmer (Goldbird Boilers only) Isolate power supply. Remove top casing (4 studs) and control panel cover (1 screw). Remove 2 screws securing blanking plate/programmer bracket. Remove bracket and blanking plate from the control panel.
System Wiring Diagrams – Goldbird Boilers with Internal Programmer Note: Bluebirds and Whitebirds should be treated as simple boilers and wired as per the control pack manufacturers instructions. 5.6.1 Honeywell ‘Y’ Plan – Independant CH&DHW (fully pumped) BLUE G/YELLOW V4073A MID POSITION WHITE ZONE...
Page 20
5.6.2 Honeywell ‘S’ Plan – Independant CH&DHW (fully pumped) Note: Bluebirds and Whitebirds should be treated as simple boilers and wired as per the control pak manufacturers instructions. V4043H ZONE VALVE HTG V4043H ZONE VALVE DHW BLUE MOTOR MOTOR G/YELLOW 240V 50Hz L641A...
Air supply for combustion and ventilation (see BS 5410) Open Flue Boilers When the boiler is sited in a cellar where the only access for combustion and ventilation air is at high level then the combustion air should be ducted to low level. Combustion Air Supply Boiler in Room Balanced Flue Boilers...
Flues Conventional Flues The flue should be designed in accordance with the local bye-laws and the Clean Air Act. Draught stabilisers are not recommended for oil fired boilers. Sharp bends or horizontal runs should be avoided and the flue should terminate 2 feet (600mm) above the ridge of the dwelling.
Page 26
Terminal Position Min Distance Below gutters, soil pipes or drain pipes 1,000 From a door, window or air vent Above ground, flat roof or balcony level Below eaves or balconies 1,000 From an internal or external corner From a terminal facing the terminal From a surface facing the terminal Vertically from a terminal on the same wall 1,500...
Installation of Flue TOP PANEL BLANKING PLATE OPTIONAL FLUE DRESSING RING TOP PANEL FLUE TERMINAL OPTIONAL EXTENSION PIECES FLUE GASKET HORIZONTAL FLUE ADAPTER TEST HOLE PLUG CONVENTIONAL FLUE RING AIR INTAKE Easy Fit ADAPTER SPIGOT & Balanced Flue BOILER LID GASKET (BF-R) AIR INTAKE...
Page 28
8.3.1 Installation of a Flue (BF-R, HLBF-R, VBF) Make a suitable sized hole in the wall or ceiling for the flue kit. Add the dimensions given on pages 7 (Dimension G) and 10 (Flue Vertical Dimension). The cavities around the opening must be sealed and protected by a non-combustable sleeve. Remove the top panel (kitchen and utility models) and the combustion chamber lid.
8.3.2 Installation of High Level Balanced Flue (HLBF) Installation instructions as per the balanced flue except there are no seals involved as the flue is not telescopic. There are no extension pieces available for these units and only 2 rearward facing options are recommended for the 90/120 range of boilers. Installation of Boilers Installation of 120/150 and 150/200 White Casings MAIN CASING...
Page 30
Installation of Industrial Bluebird Casings CASING LEFT HAND REAR SIDE CASING CASING FRONT CASING CONTROL RIGHT HAND THERMOSTAT SIDE CASING BOILER DOOR Remove the boiler door (8 bolts) and place the 2 side panels onto the boiler plinth locating the studs on the bottom edge of the casing into the corresponding holes on the plinth.
Kabin Pak Installations Although the Standard and Slimline Kabin Paks are manufactured from galvanised steel, it is recommended that after a period of weathering (approx 4-8 weeks) that the Kabin Pak is painted with a suitable primer and finish coat to prevent corrosion. When using the Kabin Paks with the integral low level flue only 28 second redwood number 1 (kerosine) may be used in order to comply with building regulations.
Fitting a Standard Kabin Pak Vertical Flue Adaptor Remove the 2 screws connecting the flue main body to the Kabin Pak and lift off. It may be necessary to break the seal between the flue main body and the top of the flue pipe.
Fitting a Slimline Kabin Pak Vertical Flue Adaptor Remove the flue terminal (4 screws) and fit the adaptor as shown (4 screws). FLUE TERMINAL VERTICAL FLUE ADAPTOR Note: Where there is a possibility of air being trapped in the boiler the installer must ensure that the automatic air vent is fitted to the boiler.
10.0 Oil Supply Oil Tank Steel tanks constructed to BS 799 Part 5 1987 should be painted on the outside only and mounted on piers to prevent corrosion. Plastic oil tanks are also available and can be suitable for installation at ground level. However, kerosine should never be stored in translucent plastic containers.
10.2 Two Pipe System APPROVED 20mm PER SITE GAUGE METRE SLOPE WATER SEPARATOR Total Maximum Pipe Length (m) Lift H I.D. 8 mm I.D. 10 mm 10.3 De-aerator System FIRE VALVE SENSOR DE-AERATOR MAY BE ABOVE OR BELOW BURNER AND MUST BE POSITIONED OUTSIDE APPROVED SITE GAUGE...
10.4 One Pipe Lift APPROVED 20mm PER METRE SLOPE SITE GAUGE Note: The pump vacuum should not exceed a maximum of 0.4 bar. Above this gas is released from the WATER oil thus leading to burner lock out. SEPARATOR Total Maximum Pipe Length (m) Lift H ID 8mm ID 10mm...
11.0 Burners 11.1 RDB Burner The burner is fitted with the correct nozzle and the pressure set. All that is further required before commissioning, is to connect the oil and electricity supply. Pump Air damper adjustment screw Control box Air tube connection (B/F) or inlet cover Reset button with lock-out lamp Pump pressure adjustment screw Flange with insulating gasket...
11.3 G20S Burner Return line Hydraulic jack with air-damper Suction line Combustion head adjustment screw Gauge connection Lock-out lamp and reset button Pump pressure regulator Flange with insulating shield Suction gauge connection Start delaying device 11.4 Oil Supply (Pump) The burner is supplied for use with a one pipe system. For use on a two pipe system, it is necessary to remove the return port plug and fit a small by-pass plug as shown.
11.5 Air Damper Adjustment The setting is purely indicative. Each installation however, has its own unpredictable working conditions: actual nozzle output; positive or negative pressure in the combustion chamber, the need of excess air, etc. All these conditions may require a different air-damper setting. 11.6 Electrode Setting Attention Before assembling or removing the nozzle,...
12.0 Servicing and Commissioning 12.1 Commissioning Note: IT IS RECOMMENDED THAT AN OFTEC TRAINED AND REGISTERED TECHNICIAN SHOULD BE USED. IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENSURE THAT THE BOILER IS PROPERLY COMMISSIONED. SEE BS 5410. FAILURE TO DO SO MAY INVALIDATE THE WARRANTY.
7 day central heating and hot water HORSTMANN TIMERS & CONTROLS Ltd: control; extremely reliable and easy to operate. NEWBRIDGE ROAD, BATH. Properly programmed it will help you save energy 626 OEM - WARMFLOW and create a comfortable environment in your home. 220-250V 50Hz 5(2)A T.55...
Page 42
Setting the Time of Day Press the SET button so that the SET indicator is pointing to the CLOCK position on the front of the programmer. The DAY OF THE WEEK indicator will now flash. Use the PLUS(+) or MINUS(-) buttons to move the DAY OF THE WEEK Indicator to the current day of the week.
Page 43
The display will now show ‘1 ON’ and the first ON time for that day will flash. Adjust the flashing time as required by using the (+) AND (-) BUTTONS THEN PRESS ENTER. The display will now show ‘1 OFF’ and the first programmed OFF time for the day will flash.
Page 44
Three of the most common systems used in conjunction with the 626 programmer are shown schematicaly in the installation manual. Information for use with various systems is available from Warmflow on (028) 9262 1515 on request. Hot water ON indicator.
Page 45
Programme Selection The following programmes can be selected for either HOT WATER by itself, CENTRAL HEATING by itself or HOT WATER and HEATING together. AUTO When AUTO is selected the programmer will switch ON and OFF according to the switching times held in the memory, i.e. up to three ON/OFF periods per day. ALL DAY When ALL DAY is selected the programmer will switch the system on at the 1st ON TIME and OFF at the 3rd OFF TIME.
Automatic Air Vent c/w Check Valve Drain Cock Pressure Relief Valve 2132 Grundfos 15/60 Pump Low Pressure Switch 2270 50/70 Baffle and 50/90 Slimline Top Baffle 1910 50/90 Slimline Middle Baffle 2799 50/90 Front Servicing Top Baffle 2814 50/90 Front Servicing Middle Baffle 2817 50/90 Bottom Baffle (Front Servicing &...
Page 52
Manchester, M40 7AS Dublin Tel: (028) 9262 1515 Tel: (0161) 205 4202 Tel: (01) 841 6158 Fax: (028) 9262 0869 Fax: (0161) 205 4818 Fax: (01) 841 6614 E-mail: sales@warmflow.co.uk E-mail: sales@warmflowgb.co.uk technical@warmflow.co.uk technical@warmflowgb.co.uk service@warmflow.co.uk service@warmflowgb.co.uk ISO 9001/2002 CERT. No. FM 29884 This manual is accurate at the date of printing (E&OE) but will be superseded and should be disregarded if...
Need help?
Do you have a question about the 50/70 and is the answer not in the manual?
Questions and answers
Does it have a frost if so where is it green 70 pak/he