Daikin FXSQ-P Technical Data Manual
Hide thumbs Also See for FXSQ-P:

Advertisement

Air Conditioners

Technical Data

R o u n d Fl ow Ca s s e t te
E E D E N 1 0 - 2 0 0
FXSQ-P

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FXSQ-P and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin FXSQ-P

  • Page 1: Technical Data

    Air Conditioners Technical Data R o u n d Fl ow Ca s s e t te E E D E N 1 0 - 2 0 0 FXSQ-P...
  • Page 2 Air Conditioners Technical Data R o u n d Fl ow Ca s s e t te E E D E N 1 0 - 2 0 0 FXSQ-P...
  • Page 3: Table Of Contents

    • Indoor Unit • Round Flow Cassette • FXSQ-P TABLE OF CONTENTS FXSQ-P Specifications ............2 Technical Specifications .
  • Page 4: Specifications

    • Indoor Unit • Round Flow Cassette • FXSQ-P Specifications t e m U n i S y s o o r Q - P u n d ® I n d V R V F X S 1-1 Technical Specifications...
  • Page 5 • Indoor Unit • Round Flow Cassette • FXSQ-P Specifications 1-1 Technical Specifications FXSQ20P7VEB FXSQ25P7VEB FXSQ32P7VEB FXSQ40P7VEB FXSQ50P7VEB Sound pressure level Cooling High Heating Super high High Refrigerant Type R-410A Control Electronic expansion valve Piping connections Liquid Type Flare connection 6.35...
  • Page 6 • Indoor Unit • Round Flow Cassette • FXSQ-P Specifications 1-1 Technical Specifications FXSQ63P7VEB FXSQ80P7VEB FXSQ100P7VEB FXSQ125P7VEB FXSQ140P7VEB Type Sirocco fan Quantity Air flow rate - 50Hz Cooling High m³/min 19.5 m³/min Heating High m³/min 19.5 m³/min Air flow rate - 60Hz Cooling High m³/min...
  • Page 7: Electrical Specifications

    • Indoor Unit • Round Flow Cassette • FXSQ-P Specifications 1-2 Electrical Specifications FXSQ20P7VEB FXSQ25P7VEB FXSQ32P7VEB FXSQ40P7VEB FXSQ50P7VEB Power supply Name Phase Frequency 50/60 Voltage 220-240/220 Voltage range Min. -10 0d Max. 10 0d Current - 50Hz Minimum circuit amps (MCA)
  • Page 8: Electrical Data

    • Indoor Unit • Round Flow Cassette • FXSQ-P Electrical data FXSQ-P Units Power Supply Model Type Volts Min. Max. FXSQ20 FXSQ25 FXSQ32 FXSQ40 FXSQ50 50/60 220~240V/220V -10% +10% FXSQ63 FXSQ80 FXSQ100 FXSQ125 FXSQ140 YMBOLS OTES MCA : Min.Circuit Amps. (A) Voltage range : Max.
  • Page 9: Safety Device Settings

    • Indoor Unit • Round Flow Cassette • FXSQ-P Safety device settings FXSQ20-140P Safety devices PC Board Fuse 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 3.15A 3.15A 3.15A 3.15A 3.15A 3.15A 3.15A 3.15A 3.15A 3.15A PC Board Fuse (Fan Driver)
  • Page 10: Options

    • Indoor Unit • Round Flow Cassette • FXSQ-P Options FXSQ20-140P Options Item Type FXSQ20,25,32 FXSQ40,50 FXSQ63,80 FXSQ100,125,140 Panel related Decoration panel (*5) BYBS32 BYBS45D BYBS71D BYBS125D Air inlet and air discharge outlet related Air discharge adapter for round duct...
  • Page 11: Capacity Tables

    • Indoor Unit • Round Flow Cassette • FXSQ-P Capacity tables 5 - 1 Cooling Capacity Tables FXSQ-P TC: Total Capacity: kW ; SHC: Sensible heat capacity: kW Indoor air temperature Outdoor 14.0WB 16.0WB 18.0WB 19.0WB 20.0WB 22.0WB 24.0WB Unit size air temp.
  • Page 12 • Indoor Unit • Round Flow Cassette • FXSQ-P Capacity tables 5 - 1 Cooling Capacity Tables FXSQ-P TC: Total Capacity: kW ; : Sensible heat capacity: kW Indoor air temperature Outdoor 14.0WB 16.0WB 18.0WB 19.0WB 20.0WB 22.0WB 24.0WB Unit size air temp.
  • Page 13: Heating Capacity Tables

    • Indoor Unit • Round Flow Cassette • FXSQ-P Capacity tables 5 - 2 Heating Capacity Tables FXSQ-P Indoor air temperature: °CDB Outdoor air temp. Unit Size 16.0 18.0 20.0 21.0 22.0 24.0 °CDB °CWB -19.8 -20.0 -18.8 -19.0 -16.7 -17.0...
  • Page 14 • Indoor Unit • Round Flow Cassette • FXSQ-P Capacity tables 5 - 2 Heating Capacity Tables FXSQ-P Indoor air temperature: °CDB Outdoor 18.0 21.0 24.0 air temp. Unit size 16.0 20.0 22.0 °CDB °CWB -19.8 -20.0 -18.8 -19.0 -16.7 -17.0...
  • Page 15: Dimensional Drawings

    • Indoor Unit • Round Flow Cassette • FXSQ-P Dimensional drawings FXSQ20-32P View A-A Detail B Suspension bolt Detail B (Service space) (Suspension position) NOTE Name Description Liquid pipe connection ø 6.35 flare (connection) Refer to ‘outlook drawing for installing optional accessories’...
  • Page 16 • Indoor Unit • Round Flow Cassette • FXSQ-P Dimensional drawings FXSQ63-80P View A-A Detail B Suspension bolt Detail B or more (Service space) (Suspension position) NOTE Name Description Liquid pipe connection ø 9.52 flare (connection) Refer to ‘outlook drawing for installing optional Gas pipe connection ø...
  • Page 17: Centre Of Gravity

    • Indoor Unit • Round Flow Cassette • FXSQ-P Centre of gravity FXSQ-P Model FXSQ20~32 FXSQ40,50 FXSQ63,80 1000 FXSQ100,125,140 1400 4TW31189-1B • VRV® Systems • Indoor Unit...
  • Page 18: Piping Diagrams

    • Indoor Unit • Round Flow Cassette • FXSQ-P Piping diagrams FXSQ20-140P Refrigerant flow Heat exchanger Cooling Heating Refrigerant pipe connection port diameters Model Liquid FXSQ20,25,32,40,50 Ø12.70 Ø6.35 FXSQ63,80,100,125,140 Ø15.90 Ø9.52 Liquid pipe connection port Filter Filter Electronic expansion valve...
  • Page 19: Wiring Diagrams

    • Indoor Unit • Round Flow Cassette • FXSQ-P Wiring diagrams 9 - 1 Wiring Diagrams - Single Phase • VRV® Systems • Indoor Unit...
  • Page 20: Sound Data

    • Indoor Unit • Round Flow Cassette • FXSQ-P Sound data 10 - 1 Sound Power Spectrum FXSQ20-25P FXSQ32P Octave band center frequency [dB] Octave band center frequency [dB] High-tap High-tap Medium-tap Medium-tap Low-tap Low-tap 3TW31187-2 3TW31207-2 Notes Notes Data is valid at free field condition...
  • Page 21 • Indoor Unit • Round Flow Cassette • FXSQ-P Sound data 10 - 1 Sound Power Spectrum FXSQ80P FXSQ100P Octave band center frequency [dB] Octave band center frequency [dB] High-tap High-tap Medium-tap Medium-tap Low-tap Low-tap 3TW31247-2 3TW31257-2 Notes Notes Data is valid at free field condition...
  • Page 22: Sound Pressure Spectrum

    • Indoor Unit • Round Flow Cassette • FXSQ-P Sound data 10 - 2 Sound Pressure Spectrum FXSQ20-25P FXSQ32P Octave band center frequency [dB] Octave band center frequency [dB] High-tap High-tap Medium-tap Medium-tap Low-tap Low-tap 3TW31187-1 3TW31207-1 Notes Notes dBA = A-weighted sound power level. (A-scale according to IEC) dBA = A-weighted sound power level.
  • Page 23 • Indoor Unit • Round Flow Cassette • FXSQ-P Sound data 10 - 2 Sound Pressure Spectrum FXSQ80P FXSQ100P Octave band center frequency [dB] Octave band center frequency [dB] High-tap High-tap Medium-tap Medium-tap Low-tap Low-tap 3TW31247-1 3TW31257-1 Notes Notes dBA = A-weighted sound power level. (A-scale according to IEC) dBA = A-weighted sound power level.
  • Page 24: Fan Characteristics

    • Indoor Unit • Round Flow Cassette • FXSQ-P Fan characteristics 11 - 1 Fan Characteristics FXSQ20-25P Fan characteristics (1) Fan characteristics (3) (Airflow auto adjustment) Upper limit of ESP H (max. ESP) (max. ESP) Upper limit of ESP Upper limit of ESP by airflow auto adjustment M (max.
  • Page 25 • Indoor Unit • Round Flow Cassette • FXSQ-P Fan characteristics 11 - 1 Fan Characteristics FXSQ40-50 Fan characteristics (1) Fan characteristics (3) (Airflow auto adjustment) H (max. ESP) Upper limit of ESP Upper limit of ESP (max. ESP) Upper limit of ESP by...
  • Page 26 • Indoor Unit • Round Flow Cassette • FXSQ-P Fan characteristics 11 - 1 Fan Characteristics FXSQ80P7 Fan characteristics (1) Fan characteristics (3) (Airflow auto adjustment) Upper limit of ESP H (max. ESP) Upper limit of ESP (max. ESP) Upper limit of ESP by M (max.
  • Page 27 • Indoor Unit • Round Flow Cassette • FXSQ-P Fan characteristics 11 - 1 Fan Characteristics FXSQ125P Fan characteristics (1) Fan characteristics (3) (Airflow auto adjustment) H (max. ESP) Upper limit of ESP (max. ESP) Upper limit of ESP Upper limit of ESP by...
  • Page 28: Installation

    • Indoor Unit • Round Flow Cassette • FXSQ-P Installation 12 - 1 Installation Method FXSQ-P Rear Suction Bottom Suction Ceiling return Ceiling return Drain pump up height Direct installation of inlet panel Installation with duct EKBYBSD is required for direct...
  • Page 29: Filter Installation Method

    • Indoor Unit • Round Flow Cassette • FXSQ-P Installation 12 - 2 Filter Installation Method FXSQ-P (or less) Installation without air inlet duct Installation with air inlet duct OTES Description When installing the unit with rear Suspended Ceiling suction, a service opening is...
  • Page 30: Switch Box Connection

    • Indoor Unit • Round Flow Cassette • FXSQ-P Installation 12 - 3 Switch Box Connection FXSQ20-140P 3TW31184-5A • VRV® Systems • Indoor Unit...
  • Page 31 The present publication is drawn up by way of information only and does not constitute an offer binding conditioning equipment, compressors and refrigerants upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its has led to its close involvement in environmental issues.

Table of Contents

Save PDF