Installation and Maintenance Instructions
DX100BR
DX100BTR
(92997AW)
(92998AW)
DX100BS
DX100BTS
(93017AW)
(93018AW)
DX100B
DX100BHTR
DX100BHPTR
(92999AW)
(93000AW)
DX100BHTS
DX100BHPTS
(93019AW)
(93020AW)
DX100BPR
(93001AW)
DX100BPS
(93002AW)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DX100B and is the answer not in the manual?

Questions and answers

Summary of Contents for Xpelair DX100B

  • Page 1 Xpelair Simply Silent ™ DX100B Installation and Maintenance Instructions DX100BR DX100BTR DX100BHTR DX100BHPTR DX100BPR (92997AW) (92998AW) (92999AW) (93000AW) (93001AW) DX100BS DX100BTS DX100BHTS DX100BHPTS DX100BPS (93017AW) (93018AW) (93019AW) (93020AW) (93002AW)
  • Page 2: Installation And Maintenance Instructions

    Installation and Maintenance Instructions Humidistat, Pull Standard Timer Humidistat, Timer Cord, Timer Pull Cord DX100BR DX100BTR DX100BHTR DX100BHPTR DX100BPR (92997AW) (92998AW) (92999AW) (93000AW) (93001AW) DX100BS DX100BTS DX100BHTS DX100BHPTS DX100BPS (93017AW) (93018AW) (93019AW) (93020AW) (93002AW) • Do read the entire instruction leaflet before commencing installation. • Do install each fan with a means for disconnection in all poles in the fixed wiring. • Do make sure the mains supply is switched off before attempting to make electrical connections or carry out any maintenance or cleaning. • Please leave this leaflet with the fan for the benefit of the user.
  • Page 3: Installation

    • If installing in a room containing a fuel made by children. burning device which has a non-balanced flue, it is the installer’s responsibility to All Xpelair Simply Silent™ DX100B AC ensure that there is enough replacement air fans have the following features: to prevent fumes being drawn down the flue •...
  • Page 4: Overall Dimensions (Mm)

    Overall Dimensions (mm) Back plate IMPORTANT – PLEASE READ fixing positions Adjusting the humidity setting Fan switches on Fan does not at lower level of switch on until condensation higher level of (anti-clockwise) condensation (clockwise) MORE SENTITIVE (RH = 50%) LESS SENTITIVE (RH = 95%) Factory settings: Timer 15 minutes, RH 75% Adjusting the run on timer setting Fan runs on for a Fan runs on for a shorter time when longer time when the external switch the external switch...
  • Page 5: Wiring And Setting Up

    Wiring and setting up SEE DETAIL A DETAIL A SCALE 2.000 HIGH LOW CUSTOMER SPEED SPEED CONNECTION TERMINAL SET JUMPER TO REQUIRED POSITION FOR SPEED SETTING LEVEL LINE DX100BR / DX100BS DX11BPR / DX100BPS SEE DETAIL C DETAIL B HIGH SCALE 2.000 SEE DETAIL B SPEED LOW SPEED SET JUMPER TO REQUIRED POSITION FOR SPEED SETTING CUSTOMER CONNECTION TERMINAL DETAIL C SCALE 2.000 OVER-RUN...
  • Page 6 Wiring and setting up SEE DETAIL D DETAIL D SCALE 2.000 OVER-RUN TIMER HUMIDISTAT SEE DETAIL E CUSTOMER CONNECTION TERMINAL LOW SPEED DETAIL E HIGH SCALE 2.000 SPEED SET JUMPER TO REQUIRED LEVEL LINE POSITION FOR SPEED SETTING DX100BHTR / DX100BHTS SEE DETAIL F SEE DETAIL G LOW SPEED DETAIL F SCALE 2.000 HIGH SPEED SET JUMPER TO REQUIRED POSITION FOR SPEED SETTING DETAIL G...
  • Page 7 • A 100mm diameter prepared hole for the DX100BPR / DX100BPS Connection to the external grille (not supplied), ideally positioned supply can be made by a flexible 2-core cable to allow condensation to run away from the first complete with 3 pin plug for insertion into an bend in the duct, towards the external grille. approved 10A GPO or directly wired through an • Appropriate ancillaries for termination. These approved 10A wall mounted surface switch with items are available from Xpelair: at least 3mm clearance between contacts. 1. 3m flexible ducting Ref: 89663AA. If the duct passes through a cold space use For Australia Only –DX100BTR / DX100BTS / insulated duct ref: 89847AA. DX100BHTR / DX100BHTS / DX100BHPTR / 2. Soffit Grille Ref: 89742AW. DX100BHPTS These models are permanently connected to the supply and operation is If window mounting the fan, you will also need: controlled by a remote switch. They should...
  • Page 8: Fan Settings

    DX100BR/DX100BS DX100BPR/DX100BPS TERMINALS FUSE DOUBLE POLE ISOLATING SWITCH DX100BTR/DX100BTS ON/OFF SWITCH TERMINALS (REQUIRED) LAMP (IF REQUIRED) FUSE DOUBLE POLE ISOLATING SWITCH DX100BHTR/DX100BHTS ON/OFF SWITCH DX100BHPTR/DX100BHPTS TERMINALS (OPTIONAL) LAMP (IF REQUIRED) FUSE DOUBLE POLE ISOLATING SWITCH For fixed wiring circuits the protective fuse for the appliance must not exceed 5A. Wire the electrical connections.
  • Page 9: Using The Fan

    • External operation - Use the external on/off of with household waste. switch. When the fan is switched off, the fan continues to operate for the adjustable time Please recycle where facilities exist. delay then goes into automatic mode. Check with your local authority for DX100BHPTR / DX100BHPTS Only recycling advice. • Automatic mode - The fan automatically adjusts to slow changes in natural humidity Guarantee levels without operating the fan. If the humidity levels increase at a rate slower than 5% RH in 5 minutes, up to the pre-set humidity level, UK only We, Redring Xpelair Group Limited, provide a the fan will not be triggered by humidity. This guarantee against faulty parts and manufacture is to prevent nuisance triggering of the fan. If for a period of 2 years from the date of humidity levels increase quicker than 5% RH purchase. In the unlikely event of a product in 5 minutes the fan will operate. When relative breakdown during the guarantee period the humidity drops the fan continues to operate for product should be returned to the place of the adjustable time delay. purchase or to Redring Xpelair Group Limited. • External operation - Use the external on/off switch. When the fan is switched off, the fan Exclusions continues to operate for the adjustable time • This guarantee does not cover compensation...
  • Page 10 Technical advice and service Customers outside UK - see international below. United Kingdom Xpelair have a comprehensive range of services including: • Free technical advice help-desk from Engineers on all aspects of ventilation. • Free design service, quotations and site surveys. • Service and maintenance contracts to suit all requirements. Please ask for details: • By telephone on Techline: +44 (0) 844 372 7766 • By fax on Techfax: +44 (0) 844 372 7767 • At the address below Head Office, UK Sales Office and Spares Redring Xpelair Group Ltd,...
  • Page 11 Head Offi ce, UK Sales Offi ce and Spares Redring Xpelair Group Ltd, Newcombe House, Newcombe Way, Orton Southgate, Peterborough, PE2 6SE England Telephone: +44 (0) 844 372 7761 www.xpelair.co.uk www.xpelair.co.uk/international FM02118 ISO 9001: 2000 Part No: 26097AA (Revision A)