Technical data

Parameters
Model
Dehumidifying capacity, max.
Operating temperature
Working range for relative humidity
Volume of airflow, max.
Electric connection
Power consumption, max.
Fuse (home)
Condensation tank
Refrigerant
Amount of refrigerant
Weight
Dimensions (HxDxW)
Minimum distance from walls of other objects
Sound pressure level LpA (1 m; complies with DIN 45635-01-KL3)

Circuit diagram

B - 3
BLUE
H.sensor
Operating Manual – Dehumidifier TTK 100 E
Values
TTK 100 E
30 l / 24 h
5-35 °C
40-100 %
200 m³/h
230 V / 50 Hz
630 W
4.15 A
5.5 l
R410A
180 g
15.2 kg
612 x 290 x 390 mm
A: Above: 50 cm
B: Behind: 20 cm
C: Side: 20 cm
D: Front: 20 cm
46 dB(A)
HI
LO
CONTROL BOARD
T.sensor
ORANGE
YELLOW
F/MOTOR
CAPACITOR