15-
1 AC Power unit disassemblies.
1. Remove the Screw-C(M4x6) and remove the Grounding lead.
2. Remove the 3 Screws-A(M3x6) and remove the Lamp Ballast unit.
3. Remove the 3 Screws-B(M3x6) and remove the AC Shield side-B.
Fig. 15-1a
15-
2 Lamp Ballast unit disassemblies.
1. Remove the Lamp Ballast Board.
(Unhook the 4 Fixer clamps and remove the Lamp Ballast unit)
2. Remove the 2 Screws-A (M3x10) and remove the AC Inlet.
C
Grounding
Lead
A
Lamp ballast unit
AC Shield side-B
A
Fixer Clamp
Lamp Ballast Board
- 29 -
Mechanical disassemblies
B
B
A
Fig. 15-1
A
AC Inlet