  • Page 1 Ⓑ Thank you for purchasing InBody R20 Please read this manual carefully and use it with proper operation. Keep it handy for future reference. ✽This product is medical equipment.
  • Page 2 Biospace is not responsible for the performance or the use of these products. Ⓑ Biospace reserves the right to modify the dimensions or exterior of InBody R20 to improve the quality of the products, without consent of the customer.
  • Page 3 Biospace has earned international recognition for technical expertise demonstrated through the InBody series. Based on the experience and technology over the last 15 years, Biospace has Ⓑ released the body composition analyzer, the InBody R20 InBody is highly recognized for its world-best technological excellence by many customers in more than 40 different markets including the US, European countries, Japan, and more.
  • Page 4: Table Of Contents

    Connecting InBody R20 and PC Configuration InBody Test mode Weight Measurement mode Maintenance Understanding of Results 10. Error messages 11. One-minute check before calling for service Appendix ✽ More about the InBody R20 Ⓑ ✽ Specifications ✽ Customer Service Information...
  • Page 5 1. This product has been designed, manufactured, and inspected under the full quality assurance Ⓑ system of Biospace. Biospace fulfills European MDD(Medical Device Directive), and InBody R20 has acquired the CE conformity marking. 2. This equipment may cause the above mentioned medical devices to malfunction.
  • Page 6: Safety Information

    Safety Information The important information to warn you of situations which might cause major injury and/or damage to property if instructions are not carefully followed. The important information to warn you of situations which might cause minor injury and/or damage to property if instructions are not carefully followed.
  • Page 7 If service is required, contact Biospace or the supplying agency. Ⓑ 4. When connecting peripherals (optional devices) to the InBody R20 , turn on the power of the Ⓑ...
  • Page 8 1. Cross Contamination Individuals with any kind of contagious disease or infection must not use or come in contact with the platform or this product. Please be sure to clean the platform with appropriate disinfectant after each use. Never pour any liquid directly on the platform, as it may leak and cause internal damage. Use a soft cloth and appropriate ethyl alcohol to wipe off the platform.
  • Page 9 1. This equipment may cause the above mentioned medical devices to malfunction. This equipment may cause harmful interference to other devices in the vicinity, if not installed and used in accordance with the installation specifications. However, there is no guarantee that the interference will not occur for a particular installation.
  • Page 10 Indicators & Safety Symbols Disposal of old Electrical & Electronic Equipment (Application in the European Union and other European countries with separate collection system) This symbol indicates that this product shall not be treated as household waste. Instead, it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.
  • Page 11 Workplace Requirements □ Operation Environment : 10 ~ 40 ℃ (50 ~ 104 ) ℉ Temperature range Relative humidity : 30 ~ 75 % Atmospheric pressure range : 70 ~ 106 kPa □ Storage Environment : -20 ~ 70 ℃ (-4 ~ 158 ) ℉...
  • Page 12 4. You may slip off the device if you step on it with wet feet. 5. Please wrap InBody and keep it level while storing for a long period. If you have it stand upright, it may cause errors later.
  • Page 13: Product Package

    1. Product Package When opening the box, check to make sure all the following items are included. Included Items Ⓑ ① InBody R20 ② Quick Installation Guide ③ Battery (AA 1.5 V X 4 EA) ④ Lookin’Body110_R20 & User’s Manual ⑤...
  • Page 14: How To Insert The Batteries And Get Started

    InBody Test, or press button for measuring weight. Ⓑ Battery is low when is still on after you turn on InBody R20 Ⓑ Please replace the batteries when is blinking after you turned on InBody R20 Please remove the batteries from the device while not in use for a long time.
  • Page 15: Installation Pc Program

    3. Installation PC program Lookin’Body110_R20 program CD from product package.  PC System Requirements Operating System : Windows XP(SP2) / VISTA Compatible / Windows 7 CPU : Above Intel Pentium4 1Ghz, Compatible with IBM-PC HDD : Enough space for 200MB or more Main Memory(RAM) : 512MB or Above Recommended Graphic Devices : Supporting 1024X768 of Resolution, 32bit Color or Above Recommended Input Devices : Keyboard, Mouse...
  • Page 18 4) Now, program installation starts. Please install following the guide message. 5) If following message comes up on the screen after the installation is completed, do not turn off or reboot the PC and put Bluetooth dongle from product package into PC. Please use the Bluetooth dongle provided by Biospace only.
  • Page 19 6) When Bluetooth dongle is put into PC, hardware driver is automatically installed and Bluetooth icon will be created on Control Panel. Please find the Bluetooth icon from Control Panel and double click, then below screen will appear. Please set as below picture and click “OK”...
  • Page 20 7) When Bluetooth set up is over, please reboot PC as seen in the picture of 5. and complete the installation. 8) Both “R20” and “Lookin’Body110_R20” icon will be created on the desktop when the Ⓑ is completed. “R20” takes care of the communication of InBody R20 rebooting and PC.
  • Page 21 PassKey when below screen appears during the process. There is no problem for the communication even closing the below screen without PassKey input. Ⓑ 10) When Bluetooth connection is properly done, InBody R20 connection can be checked out from Bluetooth Devices at Control Panel as below picture.
  • Page 22 Ⓑ 4. Connecting InBody R20 and PC Ⓑ 1) Connect Bluetooth dongle to PC. When the InBody R20 power is on and button is pressed, the Bluetooth connection will start automatically with the display below. searching proper signal available signal progress 2) The connection is normal if stays on.
  • Page 23 4) Move to the ‘Personal Profile’ menu ) by clicking the button at upper part of the screen. 5) After the input of identification information, click “Save” button. And then, click at left upper part of screen.
  • Page 24 7) After the transmission of ID information, please step on the InBody R20 for body composition analysis. 8) After completion of InBody analysis, measured data is transferred to Lookin’Body110_R20. The measured data is found at Lookin’Body S screen as shown in the below picture when InBody analysis is successfully done.
  • Page 25 9) Also, the analysis result is found at result menu as shown in the below picture. Ⓑ 10) In case InBody analysis starts by clicking the button on InBody R20 unit not from Lookin’Body110_R20), the measured data is found at Lookin’Body S screen as shown in the below picture.
  • Page 26: Configuration

    5. Configuration A. Start Configuration When the power is off, press and hold until you see the configuration menu. B. Change Configuration Press to move the cursor in the order of Weight Offset - Hour - Minute - Month - Day - Year. The number will blink where the cursor is located.
  • Page 27 After the first access, it will access automatically without searching. When the installed PC or Bluetooth Dongle is changed, it cannot search the modified data. Ⓑ You need to initialize the access information saved in InBody R20  How to initialize  Ⓑ...
  • Page 28: Inbody Test Mode

    Weight Measurement mode is on. 2) ID Input (Input Range: 01~99, Guest Mode) When InBody mode is initiated, ID digits blink. Press to select an ID number from 01 to 99. Personal information will be saved under the selected ID number.
  • Page 29 InBody R20 can be operated for the body composition analysis without connection to PC. For more results and Ⓑ data management, however, use of InBody R20 with PC connection is recommended.. B. Tips Before InBody Test 1) Make yourself as light as possible. Wear light clothes for measurement.
  • Page 30 C. How to Hold InBody Electrode Take the hand grip and hold it with the palms and thumbs touching the hand electrodes. Step on the foot electrodes at the platform. Make sure your hands and feet on both sides are not touching each other.
  • Page 31 D. Recommended measurement posture 1) Please keep your eyes to the front. 2) Grab the hand electrodes with bare hands and be careful not to let your hands touch each other. 3) Thighs should not touch each other if possible. ✽Tip: For those whose thighs contact each other, it is recommended to wear shorts, which come down below the thighs for accurate measurement.
  • Page 32 E. Test Completion The test takes about 30 seconds. When the measurement is completed, will blink on the screen with beeps. The result will be displayed for about 1 minute. Return the hand grip to the original position after the test is completed. F.
  • Page 33: Weight Measurement Mode

    7. Weight Measurement Mode Use Weight Measurement mode when you want to just check your weight. Press when the device is off or Body composition analyzing menu is running. Please step on the platform when the Weight Measurement menu is up. The device will automatically measure your weight.
  • Page 34: Maintenance

    2) Handle the arms with care. Never apply excessive force near the hand electrode joint. The damage caused by misuse may affect the function of the internal cable and electric board. Ⓑ 3) Do not place anything on the platform or apply any pressure onto it when the InBody R20 is not in use.
  • Page 35: Understanding Of Results

    9. Understanding of Results A. Result Screen Ⓑ During measurement, the InBody R20 displays information of an examinee’s body composition on the LCD. The results are shown on the LCD while an examinee is standing on the machine. The device will be automatically turned off after 3 minutes when it is left untouched.
  • Page 36 B. Result Sheet With a printer connected to the Lookin’ Body Basic (PC Program), result sheets can be printed out. The result sheets are consumable. Use the printed result sheet provided by Biospace. Please contact Biospace or an authorized distributor to place a purchase order.
  • Page 37 C. Output Items The following are the explanations for each item. The normal range on the result sheet is the standard provided by Biospace based on the Biospace possessed reference data Basically, the result sheet shows measured values for each test item. Regarding the standard result as 100%, it shows the ratio of measured values to standard values with the bar graph’s length.
  • Page 38 The standard range of Body Fat Mass is ascertained by calculating an examinee Body Fat Mass as Ⓑ compared to the standard weight and standard Body Fat Mass. The InBody R20 displays the percentage of the standard value of Body Fat Mass scored by the examinee in a bar graph.
  • Page 39 Body Mass Index is a convenient way of assessing the degree of obesity. Body composition and Lean Body Mass are not considered. BMI is determined using only the weight and height. The Ⓑ InBody R20 identifies a standard BMI of 22 for males and 21.5 for females. Formula) BMI = weight (kg) ÷ height Determination 1) WHO Standard BMI(kg/㎡)
  • Page 40 Determination 2) Asian-Pacific Standard BMI(kg/㎡) Classification Diagnosis <18.5 Underweight Low (high risk of other clinical disease) 18.5~22.9 Normal Average >23 Overweight 23~24.9 Risky Overweight Increased 25.0~29.9 Obese step1 Moderate >30 Obese step2 Severe Ref. Korean Society for the Study of Obesity, chapter 2. Redefining and Evaluation, The Asian-Pacific perspective: Redefining Obesity and its Treatment:, 1st edition, Korean Society for the Study of Obesity, 2001, p10.
  • Page 41 5) Basal Metabolic Rate (BMR) The Basal Metabolic Rate is the mineral number of calories needed to sustain life at a resting state. BMR is directly correlated with Lean Body Mass. With age muscle depletes and BMR steadily decreases. 6) Body Fat & LBM ①...
  • Page 42 7) Impedance It shows the impedance values from the measurements at 2 frequencies (20, 100kHz). For further research purposes, from the left to the right, it shows the values for the right arm, left arm, trunk, right leg and left leg. This data can be used as an index to judge if the measurement is wrong or the unit is defective.
  • Page 43: Error Messages

    Cause 1 Bad body posture due to poor contacts at hand or foot electrodes. Actuion1 See “Chapter 6 - C. How to Hold InBody Electrode” and correct the body posture. Cause 2 Extreme dryness or callus tissues of hands and feet Action 2 Wipe palms and soles with wet tissues and try another measurement with correct position.
  • Page 44: One-Minute Check Before Calling For Service

    If you still have the problem after taking the following steps, contact the local distributor or Biospace. A. I cannot turn on the device even though I press InBody or Weight button. (Normally LCD is light up.) Cause 1 The batteries might have been fully discharged.
  • Page 45 C. Measurement data is not transferred. (When the Bluetooth is connected, the data will be automatically transferred after the measurement.) Cause 1 Poor connection of the Bluetooth dongle. Its connection can be checked by the Bluetooth icon. Action 1 Please check if there is a Bluetooth icon on the LCD and reconnect the Bluetooth dongle. Action 2 Please find the Bluetooth icon from Control Panel and double click, then below screen will appear.
  • Page 46: Appendix

    Body fat mass is determined by deducting the lean body mass from the measured weight. Ⓑ Height should be entered by the user. Weight can be directly measured on the InBody R20...
  • Page 47 But, the InBody with the technology of segmental analysis can exactly figure out difference by gender, aging, disease and ethnic without any empirical estimation. Based on the fact that fat free mass (FFM) consists of about 73.3% of body fluid, it can be concluded that the...
  • Page 48 C. Classifications Type of protection against electric shock: Internally Powered Equipment Degree of protection against electric shock: Type B Applied Parts Degree of protection against the ingress of water: Ordinary equipment: IPX0 Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide.
  • Page 49 D. Specifications BODY COMPOSITION ANALYZER of Direct Segmental Multi-frequency Items & Standard Bioelectrical Impedance Method 10 Impedance Measurements by Using 2 Different Bioelectrical Frequencies (20 ㎑ and 100 ㎑) at Each of 5 Bioelectrical Impedance(BIA) Impedance(Z) Segments (Right Arm, Left Arm, Trunk, Right Leg Measurement Items and Left Leg) Electrode Method...
  • Page 50 Biospace Co., Ltd. 518-10, Dogok 2-Dong, Gangnam-gu, Seoul 135-784, Korea TEL : 82-2-501-3939 FAX : 82-2-578-2716 Homepage://www.inbody.com E-mail : info@inbody.com Biospace Japan Inc. [JAPAN] Second Floor Ayabe Bldg., 2-17-3 Sotokanda, Chiyoda-ku, Tokyo JAPAN TEL : 81-03-5298-7667 FAX : 81-03-5298-7668,7669 Homepage : http://www.biospace.co.jp E-mail : biospace@biospace.co.jp...