Unitech MS350 Manual
Hide thumbs Also See for MS350:

Advertisement

Installation
The MS350 Wireless Imager is easy to install and use.
Please see the following figure showing the steps to perform
the installation.
* Note: Turn off the host computer before installation.
1.
Connect the interface (I/F) cable to the cradle.
2.
Connect the power cord to the cradle.
3.
Route the I/F cable and power cord through the notch.
4.
Connect the I/F cable to the host computer
communication port.
5.
Connect the AC adapter to the wall outlet.
6.
Place the imager in the cradle and verify the charge
LED is flashing. Charge the battery for at least 8 hours
before the first use.
7.
To verify operation, please link the imager with cradle
first (Refer to "Wireless Connection" in page 5). Point
the imager at the barcode and pull the trigger. The
imager should emit a beep indicating that the barcode
has been scanned and transmitted to the cradle
successfully.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS350 and is the answer not in the manual?

Questions and answers

Summary of Contents for Unitech MS350

  • Page 1 Installation The MS350 Wireless Imager is easy to install and use. Please see the following figure showing the steps to perform the installation. * Note: Turn off the host computer before installation. Connect the interface (I/F) cable to the cradle.
  • Page 2 How To Scan The imager must be pointed at slight angle to the barcode so that the light reflected off the barcode can be seen by the imager. Do not hold the imager perpendicular to the barcode. The scan line must cross the entire barcode. The imager can not read the barcode data without seeing the entire barcode.
  • Page 3 Troubleshooting If the imager can not operate properly, the following checks should be performed: The cradle uses an external power supply and the external power supply has failed, the imager will not operate. Change the power supply with a known good power supply and reset the imager.
  • Page 4 Verify the interface cable is securely connected to the cradle. Check that the barcodes are of sufficient quality to be recognized by the imager. Wrinkled, smudged, or torn labels will cause the imager to not read at all. Scan a known good label to check the imager’s read operation.
  • Page 5 Wireless Connection Linking the imager with the cradle Follow these instructions to link the two devices: Connect power to the cradle. The radio LED (marked with a light symbol) will blink amber and the cradle will beep. To ensure the cradle is unlinked from any other imager, check if the cradle send inquiry beep or not (see Inquiry Beep Control in page 18).
  • Page 6 Unlinking There are three ways to unlink an imager from a cradle: *$%-$ZZ%%* Force imager to disconnect and sleep Scan the “Force imager to disconnect and sleep” barcode – Reading the unlink barcode above while the imager is in range of the cradle will break the link between the two devices and allow another imager to link to the cradle.
  • Page 7 Push the “Reset” button on the bottom of cradle – If the cradle is linked with an imager and in range, pushing the “Reset” button (for about 2 seconds) on the bottom of cradle will drop the link between the devices. If the button is pushed while the imager is out of range, the cradle will unlink and make itself available to other imagers.
  • Page 8 Battery Charging The imager contains a 1000mAh Lithium-Ion rechargeable battery. A full charged battery will provide up to 15,000 scans over a 12 hours period. Actual charge life on the imager will depend on the configuration of how the imager is configured via the programmable feature in this manual;...
  • Page 9 How to Change the Battery In case the contained battery inside the imager needs to be replaced, please follow the procedures below: 1. Loosen the screw at the bottom of the imager. 2. Take off the battery cover out of the imager. 3.
  • Page 10 6. Place the new battery into the battery container. 7. Connect the battery cable connector to the main board. 8. Put the battery cover back to the imager handle. 9. Fasten the screw to the imager. Note: DO NOT touch the PCBA inside the imager when replacing the battery.
  • Page 11 Wireless Features The MS350 Wireless model includes an imager and a cradle. When the imager and cradle are linked together, the imager will read and decode barcodes and transmit them via a Wireless radio to the cradle. The cradle will then transmit the barcode data to the host computer over the host cable.
  • Page 12 Auto Update When this feature is enabled, an imager and its linked cradle can automatically ensure they stay in sync with regard to firmware and/or configuration. This is accomplished by the linked imager and cradle comparing firmware version number and configuration file check sum. If either is different, the cradle will automatically update the imager with its firmware/configuration.
  • Page 13 Enable firmware auto update only – Allows only firmware updating. *$%-1BA02%%* Disable auto update – No automatic updates will be performed. *$%-1BA03%%*...
  • Page 14 Deep Sleep Mode The WIRELESS imager can be placed into Deep Sleep Mode after this programmed duration (since the units’ last scanning activity). Press its trigger to wake the imager form this mode. Disable Deep Sleep Mode (Default) *$%-7AJ00%%* Duration 10 minutes - Force imager into deep sleep mode if there is no barcode read in 10 minutes.
  • Page 15 Handcuff Mode (Leash Alarm) When enabled, the Leash Alarm will force the imager to sound an alarm for a preprogrammed length of time to notify if an imager is leaving the immediate vicinity of the cradle. This is especially useful in instances where the imager might inadvertently have been placed in a bag or cart.
  • Page 16 Wireless Connectivity The MS350 can be linked to any Bluetooth (BT) enabled device which can accept such a connection with other devices. To implement this feature, user should set the imager to “Cradle/Dongle connection auto detection” first. And then set the PIN code to 0000 assigned to the target Bluetooth device.
  • Page 17 Wireless Connectivity (continued) User is also allowed to set any four- to six-character PIN code assigned to the target Bluetooth device using the setting procedures below: STATE CODE Cradle/Dongle connection auto detection *$%-1AB01%%* Program *$%+PRO* Begin PIN setting *#PIN* */0* */1* */2* */3*...
  • Page 18 Inquiry Beep Control When the cradle is not linked to an imager, the Radio LED will blink amber and the cradle will beep. This beep can be disabled or reconfigured to sound for different durations by using the following programming barcodes. Disable inquiry beep *$%-5AJ00%%* Inquiry beep continuously (Default)
  • Page 19 Inquiry beep every 50 seconds *$%-5AJ05%%* Inquiry beep every 60 seconds *$%-5AJ06%%* Inquiry beep every 70 seconds *$%-5AJ07%%*...
  • Page 20 Cradle Beep Loudness Control The beep loudness of cradle can be defined with the following levels. Cradle beep off *$%-5AK00%%* Level 1 *$%-5AK01%%* Level 2 *$%-5AK02%%* Level 3 (Default) *$%-5AK03%%* Level 4 *$%-5AK04%%* Level 5 *$%-5AK05%%*...
  • Page 21 Level 6 *$%-5AK06%%* Level 7 *$%-5AK07%%*...
  • Page 22 Additional Features Here list three additional features of MS350 wireless imager for the convenience of use to users. Download firmware from the cradle *$%-+CP%%* Download configuration parameters from the cradle *$%-+CC%%* Force cradle to reset the configuration – This feature will also force imager to reset the configuration to factory default.
  • Page 23 Default setting For each barcode shown as below: Checksum Checksum Read Code Code Type Verification Transmission Enable Enable Enable UPC-A UPC-E EAN-13 EAN-8 * Code-39 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Codabar Code-128 Code-93 &...
  • Page 24 Specification ArgoScan MS350 Specification Model MS350 Operational Light Source 630 nm Visible Red LED Optical System 2048 pixel CCD (Charge-coupled device) Depth of Scan Field 0~270mm (CODE 39, PSC=90%, 20mil) 0~180mm for 13mil 0~60mm for 5mil 5mm~50mm for 4mil Scan Speed 300 scans/sec 0.1mm (4mil)
  • Page 25 Depth-handle 33 mm Depth-head 44 mm Weight Less than 200g (with a battery) Case material ABS (over molded at contact points) Cushion material Double injection Cradle interface RS232, Keyboard wedge, USB Electrical Input Voltage 5 VDC ± 10% VDC (Cradle) Power - Operating 5 VDC (Cradle)
  • Page 26 Current – Sleep 2 mA (Imager) Light Level Up to 45000 Lux Shock (Imager) 1.5m drop onto concrete Shock (Cradle) 90cm drop onto concrete Contaminants Seals to resist airborne particulate contaminants (IP42) Ventilation None required Programming Programming Manual (Reading special barcode) method Program upgrade Enabled by built-in flash memory...
  • Page 27 Indications of MS350 Imager: Green Orange Status Red LED Beeper Link Blink A special established once beep Loss link (handcuff Sound like Blink mode grasshopper enable Loss link (handcuff Blink A special mode twice beep disable) Hardware Flash fail Program...
  • Page 28 Cradle: Green Orange Status Beeper Beeps Inquiry Blink once a second Connecting Blink Link established Hardware fail Flash Data receiving ON for from the 0.5sec status scanner Barcode data Good proof or beep transmitted Data send to Error the host Fail beep Program Flash...
  • Page 29 Programming the MS350 To program the MS350, you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. You will see a table of alphanumeric barcodes, which are used to program the various options presented.
  • Page 30 Program Barcode Program Option Bar Code Option Alphanumeric Entry Keyboard Wedge * Interface RS-232 selection Wand emulation Keyboard/RS-232 Auto detection Reserved Exit Option Barcode Back Fold Out Exit Barcode Finish barcode...
  • Page 31 Interface Selection This cradle comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, and USB interface. In most of the cases, simply selecting an appropriate cable with a device code will work for a specific interface. Interface selection: You can change factory interface default for other type interface.
  • Page 32 Keyboard wedge As a keyboard interface, the cradle supports most of the popular PCs and IBM terminals. The installation of the wedge is a fairly simple process without any changes of software or hardware. Keyboard Type: Select keyboard type connector of your host computer.
  • Page 33 Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to confirm country language that you desire. In DOS, using command “keyb” to select the desirable keyboard layout or in WINDOWS entry “Control” then pops “Keyboard”...
  • Page 34 Entry * Belgium Keyboard layout Danish France Germany Italian Portuguese Spanish Swedish Switzerland Latin American Japanese 00-08 0 : high clock rate Keyboard speed 8 : low clock rate Disable Enable * Function key Alphabetic key * Numeric keypad Alpha/Numeric key (Num lock state...
  • Page 35 only) Alt+Keypad Keyboard wedge Exit Caps Lock: By selecting Caps lock”ON” or Caps lock”OFF”, imager can get Caps Lock status. Power-on simulation: All of the PCs check the keyboard status during power-on selftest. It is recommended to Enable function if you are working without keyboard installation. It simulates keyboard timing and pass keyboard present status to the PC during power-on.
  • Page 36 Program Option Bar Code Option Alphanumeric Entry Caps lock”ON” Caps lock”OFF” * Caps lock Disable * Enable Power-on simulation 00-99 (msec) 00-99 * Inter-character delay 00-99 (10 msec) 00-99 * Block transmission delay Exit...
  • Page 38 RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 11 Xoff: Transmit Off (ASCII Code13 Flow control: None-The communication only uses TxD and RxD signals without regard for any hardware or software handshaking protocol.
  • Page 39 Program Option Bar Code Option Alphanumeric Entry None * RTS/CTS Flow control Xon/Xoff ACK/NAK RTS/CTS bracket mode 00-99 (msec) 00-99 * Inter-character delay 00-99 (10 msec) 00-99 * Block transmission delay 00-99 (100 msec) 00-99 * Response delay Exit...
  • Page 40 Program Option Bar Code Option Alphanumeric Entry 300 BPS 600 BPS Baud rate 1200 BPS 2400 BPS 4800 BPS 9600 BPS * 19200 BPS 38400 BPS None * Parity Even 8 bits * 7 bits Data bit One bit * Two bits Stop bit Exit...
  • Page 42 Pin Assignments 10-pin AS Series 10-pin RJ-45 Connector RS-232 Keyboard CLK / PC DATA / PC DATA / KB CLK / KB...
  • Page 43 Keyboard Wedge PS/2 Connector (To Host Side): Mini-DIN 6P Male Mini-DIN 6P Female DATA / PC DATA / KB VCC (+5V) CLK / PC CLK / KB Mini-DIN 6P Female Connector Mini-DIN 6P Male Connector RS-232 DB-9F Connector (To Host Side): Definition...
  • Page 44 Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of imager stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary-The trigger button acts as a switch. Press button to activate scanning and release button to stop scanning.
  • Page 45 Program Option Bar Code Option Alphanumeric Entry Good-read off Momentary * Scanning mode Alternate Timeout off Continue Test only 01-99 (second) 00-99 * Stand-by duration 01-99 (10 msec) 01-99 * Double read timeout 00-09 00-09 (00: no double * Double confirm confirm) Exit...
  • Page 46 Scan Global min./max. code length: These are to define the min/ max readable code length of all symbologies. Code length less than min. code length or more than max. code length will not be read. In popular, you can set the same value for both min.
  • Page 47 Program Option Bar Code Option Alphanumeric Entry 00-99 00-99 * Global min. code length 00-99 00-99 * Global max. code length Disable * Enable Inverted image scan Exit...
  • Page 48 Indication Exit Power on alert: After power-on the cradle it will generate an alert signal to indicate a successful self-test. LED indication: After each successful reading, the LED above the imager will light up to indicate a good barcode reading. Beeper indication: After each successful reading, the imager will beep buzzer to indicate a good barcode reading, and its Beep loudness,...
  • Page 49 Program Option Bar Code Option Alphanumeric Entry Disable Enable * Power on alert Disable Enable * LED indication Disable Enable * Beeper indication 00-07 00-07 (00 - off) * Beep loudness 00-99 (100Hz) 00-99 * Beep tone freq. 00-99 (10 msec) 00-99 *...
  • Page 50 UPCA Format Leading Data Digits Check Zero (11 Digits) Digit Read: Enable or disable the read function. Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: The leading or ending digits of barcode data characters can be truncated when these values are set to non-zero.
  • Page 51 Program Option Bar Code Option Alphanumeric Entry Disable Enable * Read Disable Enable * Check-sum transmission 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < A > Code ID setting Exit...
  • Page 52 UPCA Insertion group number selection: The imager offers max. two insertion groups for one symbology. By setting one or two digits to indicate which insertion group you want to insert. You may refer to Character insertion. The function is to insert specific characters as a group into transmitted data of selected symbologies.
  • Page 53 Program Option Bar Code Option Alphanumeric Entry 00-44 00-44 * Insert group number selection None * 2 digits Supplement digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 None Truncate leading * Truncation/ zero Expansion Expand to EAN13 Exit...
  • Page 55 UPCE Read: Format Leading Data Digits (6 Check Zero Digits) Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Program Option Bar Code Option Alphanumeric...
  • Page 56 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < E > Code ID setting Exit...
  • Page 57 UPCE Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Supplement digits: Format Supplement Digits Leading Data Digits Check 2 or 5 or Zero (6 Digits) Digit UCC/EAN Expansion: The expansion function is used only for UPCE and EAN-8 code reading.
  • Page 58: Table Of Contents

    None * 2 digits Supplement digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 None * Truncate leading Truncation/Expansion zero Expand to EAN13 Expand to UPCA Disable * Enable Expansion Disable * *OAM* Enable UPCE-1 Exit...
  • Page 59: Digits

    EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Truncate leading zero: Refer to Truncation / Expansion of UPCA. Program Option Bar Code Option Alphanumeric Entry...
  • Page 60 0-15 00-15 * Truncate ending Exit...
  • Page 61: Ucc/Ean

    EAN-13 Code ID setting: Refer to page 51 Insertion group number selection of UPCA. Insertion group number selection: Refer to Insertion group selection of UPCA. Supplement digits: Format Supplement Digits Data Digits Check 2 or 5 or (12 Digits) Digits UCC / EAN ISBN/ISSN: The ISBN (International Standard Book Number) and ISSN (International Standard Serial Number) are two...
  • Page 62 None * 2 digits Supplement digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 Disable * Enable ISBN/ISSN conversion 00-ffH ASCII 00-ffH code * G A M * * < I > ISBN ID setting Exit...
  • Page 63 EAN-8 Read: Format Data Digits Check (7 Digits) Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA.
  • Page 64 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH, 00-ffH code * < FF > Code ID setting 00-44 00-44 * Insert group number selection Exit...
  • Page 65: 2, Ucc/Ean 128

    EAN-8 Supplement digits: Format Supplement Digits Data Digits Check 2 or 5 or (7 Digits) Digits UCC/EAN 128 Truncation / Expansion: Refer to Truncate Leading zero of UPCE. Expansion: Refer to Expansion of UPCE. Program Option Bar Code Option Alphanumeric Entry None *...
  • Page 66 Disable * Enable Expansion Exit...
  • Page 67 Code 39 Read: Format Start Data Digits Checksum “ ” ( Variable) (Optional) “ ” ★ ★ Check-sum verification: The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits. Check-sum transmission: By setting Enable, checksum will be transmitted.
  • Page 68 Disable * Enable Check-sum verification Disable * Enable Check-sum transmission 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < > Code ID setting Exit...
  • Page 69 Code 39 Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Format: The Full ASCII Code-39 is an enhanced set of Code-39 that is the data with total of 128 characters to represent Full ASCII code. It is combined one of the digits +, %, $ and/ with one of the alpha digits (A to Z).
  • Page 70 Standard * Full ASCII Format Disable * Enable Append Disable * Enable Start/end transmission Exit...
  • Page 71 Interleaved 2 of 5 Read: Format Data Digits Checksum (Variable) (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 72 Disable * Enable Check-sum transmission 00-64 00-64 * Max. code leading 00-64 00-64 * Min. code leading 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < i > Code ID setting 00-44 00-44 *...
  • Page 73 Industrial 2 of 5 Read: Format Data Digits Checksum (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA.
  • Page 74 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < i > Code ID setting 00-44 00-44 * Insert group number selection Exit...
  • Page 75 Matrix 2 of 5 Eur Read: Format Data Digits Checksum (Variable) (Optional) Checksum Verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min.
  • Page 76 Disable * Enable Checksum Transmission 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < B > Code ID setting 00-44 00- 44...
  • Page 77 Insert group number * selection Codabar Exit Read: Format Start Data Digits (Variable) Checksum (Optional) End Checksum Verification: The checksum is made as the sum module 16 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
  • Page 78: Truncate Leading

    Disable * Enable Checksum Verification Disable * Enable Checksum Transmission 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < % > Code ID setting Exit...
  • Page 79 Codabar Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Start/End type: The Codabar has four pairs of Start/End pattern; you may select one pair to match your application. Start/End Transmission: Refer to Start/End Transmission of Code 39.
  • Page 80 Disable Enable * Start/End transmission Exit Code-128 Read: Format Data Digits Checksum (Variable) (Optional) Checksum Verification: The checksum is made as the sum module 103 of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Program Option Bar Code Option Alphanumeric Entry...
  • Page 81 Disable * Enable Checksum Transmission Exit...
  • Page 82 Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Format: The Code-128 can be translated to UCC/EAN-128 format if it starts with FNC1 character.
  • Page 83: Disable Enable

    0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < # > Code ID setting 00-44 00-44 * Insert group number selection Standard * UCC/EAN-128 Format Disable/Enable * Enable/Enable Append / FNC4 control Disable/Ignore Enable/Ignore Exit...
  • Page 84 Code-128 ISBT enable: This feature is commonly used in a blood bank for identification. ISBT concatenation timeout: This feature is to setup the timeout duration of ISBT concatenation. Field separator code: This feature is only used for UCC/EAN-128 format. This Field separator code means you your can reassign second or after a FNC1 for usage.
  • Page 85 Code-93 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Program Option Bar Code Option Alphanumeric Entry...
  • Page 86 Code-93 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Program Option Bar Code Option...
  • Page 87 00-ffH ASCII 00-ffH code * < & > Code ID setting 00-44 00-44 * Insert group number selection Exit...
  • Page 88 Code-11 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is presented as the sum module 11 of all data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min.
  • Page 89 Disable * Enable Checksum Transmission 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < O > Code ID setting 00-44 00-44 *...
  • Page 90 MSI/plessey Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The MSI/Plessey has one or two optional checksum digits. The checksum is presented 3 kinds of method Mod10, Mod10/10 and Mod 11/10. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits.
  • Page 91 Disable * Enable Checksum Transmission 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < @ > Code ID setting 00-44 00-44 *...
  • Page 92 UK/plessey Read: Format Data Digits Checksum1+2 (Variable) (Optional) Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
  • Page 93 Disable * Enable Checksum Transmission 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < @ > Code ID setting 00-44 00-44 *...
  • Page 94 Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 95 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < S > Code ID setting 00-44 00-44 * Insert group number selection N u m e r i c o n l y *...
  • Page 96: Truncate Leading/Ending: Refer To Truncate Leading/Ending

    Standard 2 of 5 Read: Format Data Digits Checksum1 (Variable) (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 97: Disable Enable

    Disable * *JAC* Enable Check-sum transmission 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < i > Code ID setting 00-44 00-44 *...
  • Page 98: Read

    China Post Read: Format Data Digits Checksum1 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA.
  • Page 99 Min. code length * 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < t > Code ID setting 00-44 01-44 * Insert group number selection Exit...
  • Page 100 Italian Pharmacode (Code 32) Read: Format Data Digits Checksum1 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA.
  • Page 101 Disable * Enable Read 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 01-ffH code * < p > Code ID setting 00-44 00-44...
  • Page 102: Disable Enable

    Insert group number * selection Disable * Enable Leading “A” Exit Code-16K Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Program Option Bar Code Option...
  • Page 103 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < > Code ID setting...
  • Page 104 00-44 00-ffH 00-44 Insert group number * selection Exit...
  • Page 105 PDF-417 Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA.
  • Page 106 Program Option Bar Code Option Alphanumeric Entry Disable Enable * Read 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code < P > * Code ID setting 00-44 00-44 * Insert group number selection Disable *...
  • Page 107 EAN UCC Composite For the coupon extended code application. Coupon extended code is a supplementary barcode that is printed to the right of the UPC/EAN in UCC/EAN-128 symbology. Program Option Bar Code Option Alphanumeric Entry Disable * Enable *YAA* Read 0-15 00-15 *YAF*...
  • Page 108 Disable * Enable *YAK* UCC / EAN128 emulation Exit...
  • Page 109: Checksum

    RSS-14 Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. UCC/EAN 128 emulation: Refer to Transmission, Code ID transmission must be set as AIM ID enable.
  • Page 110 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < R4 > Code ID setting 00-44 00-44 * Insert group number selection Disable * Enable UCC/EAN128 emulation Exit...
  • Page 111 RSS-Limited Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation of RSS-14.
  • Page 112 00-ffH ASCII 00-ffH code * < RL > Code ID setting 00-44 00-44 * Insert group number selection Disable * Enable UCC/EAN128 emulation Exit...
  • Page 113 RSS-Expanded Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation of RSS-14.
  • Page 114 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < RX > Code ID setting 00-44 00-44 * Insert group number selection Disable * Enable UCC/EAN128 emulation Exit...
  • Page 115 Micro-PDF Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Disable Enable *XAA*...
  • Page 116 00-44 00-44 *XAI* * Insert group number selection None GLI protocol *XAJ* Escape sequence ECI protocol * transmit Exit...
  • Page 117 String setting / Transmission (Prefix / Suffix) Prefix / Suffix characters setting: Characters defined as prefix or suffix characters will be transmitted immediately with the scanned data for all symbologies. Up to 22 ASCII characters can be defined as Prefix or Suffix. Format of barcode data transmission: Code Barcode...
  • Page 118 Program Option Bar Code Option Alphanumeric Entry None * 1-22 characters Prefix characters 00-ffH ASCII setting code None * 1-22 characters Suffix characters 00-ffH ASCII setting code Exit...
  • Page 119 String setting / Transmission (Preamble/Postamble) Preamble/ Postamble characters: Preamble or Postamble characters will be appended to the data automatically for all symbologies. However, the transmission will not activate unless Preamble / Postamble transmission is enabled. Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted.
  • Page 120 Program Option Bar Code Option Alphanumeric Entry 1-22 characters * “ ” PREAMBLE Preamble characters 00-ffH ASCII setting code Disable * Enable Preamble transmission 1-22 characters * “ ” POSTAMBLE Postamble 00-ffH ASCII characters setting code Disable * Enable Postamble transmission Exit...
  • Page 121 String setting / Transmission (Insert Group Characters) Insert G1/G2/G3/G4 character setting: The imager supports inserting two groups with each group 22 characters into transmitted data of selected symbologies. The two groups can be inserted into scanned data of the selected symbologies or positioned at leading / ending of data.
  • Page 122 5) Repeat the same procedure in Insert G2 characters setting. 6) Scan Exit barcode. Insert data group 1-4 position. Please refer to the specific barcode that you want to use. Insert data group 1-4 position: The imager offers 4 positions to insert among the symbol. The position default value is “00”...
  • Page 123 Program Option Bar Code Option Alphanumeric Entry 1-22 characters * “GROUP1” Insert G1 characters 00-ffH ASCII setting code 1-22 characters * “GROUP2” Insert G2 characters 00-ffH ASCII setting code 1-22 characters * “GROUP3” Insert G3 characters 00-ffH ASCII setting code 1-22 characters *...
  • Page 124 00-64 00-64 (00: no insertion) * Insert data group 2 position 00-64 00-64 (00: no insertion) * Insert data group 3 position 00-64 00-64 (00: no insertion) * Insert data group 4 position Exit...
  • Page 125 String setting / Transmission (Others) Code ID position: Upon your usage, the transmitting position of Code ID can be selected to place Before Code Data or After Code Data when it is transmitted. Code ID transmission: If your application is needed to transmit Code ID, you must set this to Proprietary ID or AIM Code length transmission: A number of data digits can be transmitted before the code data when Enable is selected.
  • Page 126 Before code data * After code data Code ID position Disable * Proprietary ID Code ID AIM ID transmission Disable * Enable Code length transmission Disable * Enable Code name transmission Disable * Upper case Case conversion Lower case (For barcode data only) Exit...
  • Page 127 Test Chart Test Chart Test Chart Test Chart ( B a r c o d e s a m p l e s m a r k e d w i t h s y m b o l “ * ” a r e e n a b l e d i n i t i a l l y . ) CODABAR-PARA CODE-11 PARA CODE-128 PARA *...
  • Page 128 PDF-417 * STANDRAD-25 PARA CODE-16K 8 7 5 4 9 8 7 5 4 9 8 7 5 4 9 8 7 5 4 9 EAN-8 PARA * INDUSTRIAL-25 PARA UPCE PARA *...
  • Page 129 INTERLEAVED-25 PARA * MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA * UK/PLESSEY PARA Micro-PDF *...
  • Page 130 ASCII Code Table N o t e : F o r k e y b o a r d w e d g e o n l y . N u l l N U L D L E S O H D C 1 D o w n S T X...
  • Page 131 * ! B C * Barcode standard parameter setting list If you wish to display the current barcode reading configuration of your MS350 imager over the host terminal/computer, scan the Barcode standard parameter setting list bar code. System parameter setting list...
  • Page 132 Reset cradle to factory default settings *$%-+IC%%* WARNING: Default value initialization If you wish to return the MS350 imager to all the factory default settings, scan the above barcode will perform the feature. However, the cradle will be set to factory default settings at the same time.
  • Page 133 Finish...

Table of Contents