196 / 196 M electronic IP65
en
1x
1x
CALIBRATE
5 sec
1x
1x
13
Calibration
1. Switch on the electronic spirit level. Use the vial to
accurately align the unit to a wall, for example, until
the vial bubble is in the middle between the vial rings.
If mainly used for vertical measurements, the calibration
can also be undertaken with the vertical vial.
2. Hold the electronic spirit level in this position and
press the CAL button.
The CAL display shows calibration mode.
3. Calibration starts when the CAL button is pressed again.
Newly calibrated value with
deviation of ≥ 1° from
factory setting
Vibration during
calibration
Calibration completed
successfully
180°
The reverse test checks the calibration.
Angle ≤ 0.1° to normal
position
Recalibrate spirit level
Recalibrate spirit level
Spirit level ready
Spirit level ready