Installation, Maintenance and User Instructions
Zip Tudor II & Contract II
Point of use Water Heaters
Models:
P4/52, P4/52UB, P4/102,
P4/102UB. C2/50, C2/100
Please read these instructions carefully before commencing installation of the water heater.
Please leave these instructions with the end user after installation.
,
C3/50.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Tudor II P4/52 and is the answer not in the manual?

Questions and answers

Summary of Contents for Zip Tudor II P4/52

  • Page 1 Installation, Maintenance and User Instructions Zip Tudor II & Contract II Point of use Water Heaters Models: P4/52, P4/52UB, P4/102, P4/102UB. C2/50, C2/100 C3/50. The term ‘Zip’ is a registered trademark Zip Heaters (UK) Ltd 14 Bertie Ward Way Dereham...
  • Page 2: Table Of Contents

    Approvals The Zip Tudor II and Contract II models are approved to the LVD and EMC directives and CE endorsed. The Zip Tudor II and Contract II models have been examined, tested and found when correctly fitted to comply with the requirements of the United Kingdom Water Regulations / Byelaws (Scotland).
  • Page 3: Description

    The stored hot water is delivered from an open outlet spout (supplied with overbasin models) or a Zip approved open outlet vented tap. This type of fitting is permanently open to the atmosphere which allows the expansion of water, that occurs during the heating cycle, to be safely discharged.
  • Page 4: Warnings

    • The appliance, its wiring and piping must not be modified in any way. • In case of malfunction isolate the power supply immediately. In case of leaks also isolate the water supply. Repairs must only be carried out by Zip Heaters (UK) Ltd or an authorised Zip service engineer.
  • Page 5: Cautions

    SHOULD THE SPOUT OR OUTLET BE CONNECTED TO A TAP WHICH IS CAPABLE OF BEING CLOSED. • The Zip Tudor II and Contract II is intended for connection to mains supply only. In any other case please contact Zip on 0845 6 005 005 for advice.
  • Page 6: Technical Data

    Water connections (BSP) 1/2” Protection class IP24 All data quoted at nominal supply voltage. For higher supply pressures it is recommended that a Zip AQ3 (set at 3.5 bar) pressure reducing valve is used. CONTRACT Tudor II Tudor II, C2/50 and C2/100...
  • Page 7: Spare Parts

    Spare Parts ITEM Description PART No. P4 MODELS C2 MODELS C3 MODEL Heating element CTO111/4 Element gasket CTO116/4 Fascia CT0130 Fascia (OB) CT0107/3 Fascia (UB) CT0108/3 Thermostat CT0119/4 Re-settable cut-out CT0121/4 Re-settable cut-out CT0122 Thermal fuse CT0120 Neon light indicator CT0129/4 Retaining nut CT0115/4...
  • Page 8: Installation

    The electrical installation including earthing and cross bonding should comply with current IEE regulations and any Local Authority requirements. • Zip Contract and Tudor water heaters must be installed according to the specification on the rating plate and the technical specifications. •...
  • Page 9: Overbasin Installation

    In all underbasin installations the outlet must be connected to an open outlet type fitting approved by Zip heaters. The diagram below (fig 3) shows a typical installation of a monobloc mixer tap assembly, product ref. UB1. Alternative Zip approved products are product ref. UB6 and UB7. NOTE: When installing underbasin models it is recommended that fibre washers are used on both inlet and outlet connections to ensure a watertight seal.
  • Page 10: Electrical Installation

    Electrical Installation. WARNING: SWITCH OFF THE MAINS ELECTRICAL SUPPLY BEFORE CARRYING OUT ANY WORK INVOLVING A LIVE CIRCUIT. 230v AC SUPPLY ONLY, THIS APPLIANCE MUST BE EARTHED. Before starting installation the WARNINGS (page 3) and CAUTIONS (page 4) should be read and fully understood.
  • Page 11: Safety Cut Out

    Safety Cut Out. In the event of a malfunction that leads to an over temperature situation, a safety cut out will automatically cut off the electrical supply to the element (refer fig.4). The cut out and reset operations for the various models are described below. Models P4/52,P4/52UB, P4/102, P4/102UB A manually resettable cut out that may be reset by a qualified electrician once the fault has been corrected...
  • Page 12: Commissioning & Operation

    Very little maintenance is required, however it is recommended that the replacement of spare parts is carried out by a relevant competent person ie. Plumber or Electrician for any more information please contact the Service Dept. ZIP HEATERS (UK) LTD TEL.0845 6 005 005. Problem...
  • Page 13: Warranty

    Furthermore, this warranty does not displace any statutory warranty, but, to the extent to which Zip is entitled to do so, the liability of Zip under any statutory warranty will be limited at Zip’s option to the replacement of the appliance or supply of equivalent appliance, the payment of the cost of replacing the appliance or acquiring an equivalent appliance, or the payment of the cost of having the appliance repaired or the repair of the appliance.