G3 PRIMO CAPPUCCINO SYSTEMS TROUBLESHOOTING GUIDE MODELS: PCGT3, PCGT4, PCGT5, PCGT6 Service & Sales www.wilburcurtis.com 1-800-421-6150...
Page 2
CHASSIS VIEW HEATING TANK VIEW PART # DESCRIPTION PART # DESCRIPTION 1. WC-37126 KIT, UCM BOARD & LABEL PCGT3 15. WC-37118 KIT, WHIPPER PLATE (3/PKG) 2. WC-5310 TUBING, 5/16” ID x 1/8” W SILICONE 16. CA-1024-05 PILLAR, LOCATION BLACK 3. WC-37054 SOCKET, GEAR 17.
Page 3
PCGT4/5/6 PARTS IDENTIFICATION PART # DESCRIPTION PART # DESCRIPTION 1. WC-37126 KIT, UCM BOARD & LABEL PCGT3 18. WC-37008 KIT, TANK LID ROUND 2. WC-5310 TUBING, 5/16” ID x 1/8” W SILICONE 19. WC-5502-01 KIT, PROBE, ASSY WATER LEVEL W/HEX 3.
TROUBLESHOOTING INSTRUCTIONS POWER ISSUES The LED light on the front door are not lit: No: Replace Reset Thermostat Verify that the panel breaker is turned on. If Yes: Proceed to #5 okay, proceed STEP 2. Verify that there is 12 vac between pins 1 & Verify that the voltage at the receptacle is 2 on the 14 pin connector at the UPM and correct: L1-N = 120 vac, N-G = 0 vac.
TROUBLESHOOTING INSTRUCTIONS - continued TANK FILLING ISSUES Not filling: Overfilling: Is the water turned on? Does the tank continue to fill after the toggle switch has been turned off ? Yes: Verify 120 volts at inlet valve coil Yes: Replace Water Inlet Valve. Yes: Replace Inlet Valve Remove the Orange wire from the Wa-...