2. For 24VAC primary power, connect common side of
transformer to C terminal.
CONVENTIONAL
C
K
RC
R
U1
U1
U2
U2
HEAT PUMP
Fig. 17. Connecting C wire to terminal block.

Wiring the Thermostat

IF THE THERMOSTAT IS WIRED DIRECTLY TO THE
EQUIPMENT
1. Refer to Fig. 18. See Table 10 on page <$elempagenum
for terminal designations and "Wiring" beginning on
page 116 for more information.
2. Turn on 24VAC NOW.
NOTE: 24VAC (C wire) is required to connect RedLINK
accessories.
CONVENTIONAL
C
K
RC
R
U1
U1
U2
U2
HEAT PUMP
Fig. 18. Thermostat wired directly to equipment.
IF THE THERMOSTAT IS USED WITH AN EQUIPMENT
INTERFACE MODULE OR TRUEZONE WIRELESS
ADAPTER
1. Power the thermostat using Rc and C terminals or with
batteries. Refer to Fig. 19.
NOTE: The relay outputs and inputs on the thermostat
do not function when used with an Equipment
Interface Module or TrueZONE Wireless
Adapter.
S1
S1
S1
S1
W
O/B
Y
Y
G
G
W2
AUX
-E
Y2
Y2
A
L/A
S1
S1
S1
S1
W
O/B
Y
Y
G
G
W2
AUX
-E
Y2
Y2
A
L/A
11
VISIONPRO
CONVENTIONAL
C
K
RC
R
U1
U1
U2
U2
HEAT PUMP
Fig. 19. Inserting wires in thermostat terminal block.
Remove Coin Cell Battery Tab
1. Remove tab to activate coin cell battery.
NOTE: Coin cell battery saves time and date during a
power loss.
Fig. 20. Remove coin cell battery tab.
Mounting Thermostat on Wallplate
1. Align thermostat at bottom and snap into place as
shown.
Fig. 21. Mount thermostat.
®
8000 WITH REDLINK™
S1
S1
S1
S1
W
O/B
Y
Y
G
G
W2
AUX
-E
Y2
Y2
A
L/A
68-0312—01

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TH8320R1003 Vision Pro 8000 and is the answer not in the manual?

Questions and answers

Scott Lane
February 11, 2025

Why can’t I change the time on this thermostat

1 comments:
Mr. Anderson
February 12, 2025

To change the time on the Honeywell TH8320R1003 Vision Pro 8000 thermostat, you need to touch the current time on the display. If you are unable to change the time, possible reasons include:

1. Keypad Lockout: If the thermostat is set to "Partially Locked" or "Fully Locked," you may not have access to change the settings.
2. Installer Settings: Some settings may be restricted in commercial installations or by the installer.
3. System Configuration: If the thermostat is connected to a system that automatically updates the time (e.g., via RedLINK), manual changes may not be allowed.

Check if the keypad is locked or if your system is set to update the time automatically. If needed, consult the installer settings or reset the lockout.