Technician Setup Menu
This thermostat has a technician setup menu
for easy installer configuration. To set up the
thermostat for your particular application:
Press MENU button
1.
Press and hold the TECH SET button for
2.
3 seconds. This 3 second delay is
designed so that homeowners do not
accidentally access the installer settings.
Tech Setup Steps
Filter
Change
Temperature
Reminder
Calibration
This feature will flash
This feature allows
FILT in the display
the installer to change
after the elapsed run
the calibration of the
time to remind the
room temperature
user to change the
display. For example,
filter. A setting of
if the thermostat
OFF will disable this
reads 70° and you
feature.
would like it to read
72° then select +2.
You can adjust the
You can adjust the
filter change
room temperature
reminder from OFF
display to ready -4°F
to 2000 hours of
to +4°F above or
runtime in 50 hour
below the factory
increments.
calibrated reading.
OFF
0 ºF
Room
Minimum
Compressor
On Time
This feature allows the
installer to select the
minimum run time for
the compressor.
For example, a setting of
4 will force the
compressor to run for at
least 4 minutes every
time the compressor
turns on, regardless of
the room temperature.
You can select the
minimum compressor
run time from "off",
"3", "4", or "5" minutes.
If 3, 4, or 5 is selected,
the compressor will run
for at least the selected
time before turning off.
OFF
TECHNICIAN SETUP MENU
3.
Configure the installer options as
desired using the table below.
Use the
change settings and the NEXT key
to move from one option to the next.
Note: Only press DONE key when
you want to exit the Technician Setup
options.
Compressor
Short Cycle Delay
The compressor short
The swing setting, often
cycle delay protects the
called "cycle rate",
compressor from "short
"differential" or
cycling". This feature will
"anticipation" is
not allow the compressor
adjustable. A smaller
to be turned on for 5
swing setting will cause
minutes after it was last
more frequent cycles and
turned off.
a larger swing setting will
cause fewer cycles.
Selecting ON will not
The cooling swing
allow the compressor to
setting is adjustable
be turned on for 5
from ±0.2°F to ±2°F.
minutes after the last
For example: A swing
time the compressor was
setting of 0.5°F will turn
on. Select OFF to
the cooling on at
remove this delay.
approximately 0.5°F
above the setpoint and
turn the cooling off at
approximately 0.5°F
below the setpoint.
ON
0.5 ºF
or
keys to
Cooling
Heating
Swing
Swing
The swing setting, often
called "cycle rate",
"differential" or
"anticipation" is
adjustable. A smaller
swing setting will cause
more frequent cycles and
a larger swing setting
will cause fewer cycles.
The heating swing
setting is adjustable
from ±0.2°F to ±2°F.
For example: A swing
setting of 0.5°F will
turn the heating on at
approximately 0.5°F
below the setpoint and
turn the heating off at
approximately 0.5°F
above the setpoint.
0.4 ºF
TECH SETUP
STEPS CONTINUED
ON THE NEXT PAGE
6