INSTALLATION
Installation of your stove must comply with relevant local and national Building Regulations and
fire safety standards.
TECHNICAL
Ottawa 5 kW - Performance Test Results.
All efficiencies in table are Net values
Wood Results, 1 hour refuels
Parameter
Mean
Test Duration h
1.05
Total Efficiency
80.2 %
Nominal heat output
Mean CO emission (at 13 % O2) 0.35%
Mean flue gas temperature ºC 278
Flue gas mass flow g/s 3.3
Mean CnHm (at 13 % O2)
Mean NOx (at 13 % O2)
DIN Plus dust (at 13 % O2)s 13.3
Manufacturer's declarations Refuelling period 1 hour
Nominal output
4.8 kW
Temperature Safety Test
Distances to combustibles: Back Wall 700 mm
Max Hearth Temperatures
Nominal output
Temperature safety
76kg
Your stove will require a constant air supply, and should not be used at the same time and in
the same room/space as extractor fans or any device which may draw air supply away from the
stove. The stove should be installed on a level floor with adequate load bearing capacity.
The stove needs to stand on a hearth of non-combustible materials not less than 12mm thick
conforming to Building Regulations.
Normally for most houses in the UK no extra ventilation is required when installing a stove rated
at 5kW or less.
Note: The requirements regarding ventilation have been updated in the most recent version of
the Building
Regulations and are now based on the air permeability of the house.
NOT suitable for installation in a shared flue system.
kW 4.8
314
66
Side Wall 600 mm
61°C
77°C
3