Pre-Power Testing - Motorola PTP 300 Deployment Manual

Motorola network router user manual
Hide thumbs Also See for PTP 300:
Table of Contents

Advertisement

Before plugging the RJ45 connector fitted to the lower LPU (or if not fitted the ODU)
into the PIDU check the following resistances at the RJ45;
a.
Check the cable resistance between pins 1&2, 3&6, 4&5 and 7&8 at the RJ45.
Check against column 2 in Table 1.
b.
Resistances for each pair should be within 1ohm of each other.
c.
Check the resistance between pins 1&3 and 4&7 at the RJ45. Check against
column 3 and 4 in Table 1.
d.
Ensure that there is greater than 100K ohms between pins 1 & 8 for all cable
lengths.
e.
Ensure that there is greater than 100K ohms between pin 1 and ODU ground for
all cable lengths.
f.
Ensure that there is greater than 100K ohms between pin 8 and ODU ground for
all cable lengths.
Cat5E
Resistance
Length
between pins
(meters)
1&2, 3&6, 4&5
and 7&8
(ohms)
0
0.8
10
2.5
20
4.2
30
5.9
40
7.6
50
9.3
60
11.0
70
12.7
80
14.4
90
16.1
100
17.8
Table 1 - Resistance Table Referenced to the RJ45 at the PIDU Plus

Pre-Power Testing

Resistance
between pins
1&3
(ohms)
1.0
2.7
4.4
6.1
7.8
9.5
11.2
12.9
14.6
16.3
18
8
1
Identification of pin 1
13
Resistance
between pins
4&7
(ohms)
1.6
3.3
5.0
6.7
8.4
10.1
11.8
13.5
15.2
16.9
18.6