  • Page 3 - high level of maximal signal (8 dBu) what enables to use it at amps effect loops - silent switching and low noise level - FOOT PEDAL input for controlling it by a guitar controller e.g. G LAB GSC - 9V DC power supply.
  • Page 4 Structure On the inner side of the instruction cover are placed the pictures with elements numerated below. 1 - Effect ON/OFF footswitch 2 - A reverb LEVEL (intensity) control 3 - A reverb TIME control 4 - Effect switching on indicator 5 - “A”...
  • Page 5 Diagrams of connecting In case when you use only stompbox overdrives the DR should be connected as the last stompbox pre amp. When you use overdrive channel (or channels) of your amp the DR should be connected at the and of the signal path what means, to the amp effect loop.
  • Page 6 If your amp is equipped with SEND output signal level control then you should set the active reverb LEVEL control to maximum and set in a such way your amp SEND output signal level control to be at the edge of lighting up the DR PEAK indicator (it is recommended to set the amp channels controls at typically used positions and to check all the channels).
  • Page 7 Control settings The REVERB 1 or 2 switch enables to select sound characteristics of the used reverb. TIME controls enable adjusting the reverb time from hundreds of milliseconds up to few seconds (REVERB 2 offers longer lasting sounding). LEVEL controls enable adjusting the proportion of the resounded from zero signal to the level of 25% of the incoming one.
  • Page 8 Connecting to the GSC (Guitar System Controller) The DR can be controlled and supplied form the GSC controllers of the G LAB brand. In such a case the SW1&2 (or SW3&4) output of the GSC connect with the DR FOOT PEDAL input by a Jack/Jack mono cable.
  • Page 9 Specification Dimensions: depth 120 mm width 120 mm height 60 mm Weight 550 g IN input impedance 1 MΩ Maximal input signal 8 dBu OUT output impedance 4 kΩ Power supply 9V DC (8,7 do 9,4V regulated) Power consumption 80 mA...
  • Page 11 FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 12 Declaration of Conformity ELZAB S.A., ul. Kruczkowskiego 39, 41-813 Zabrze, Poland, declare under sole responsibility, that the following product: G LAB/ Dual Reverb G LAB DR-3 (DR-2) conforms with requirements of the EC Council Directives: ● 2006/95/EEC Low Voltage Directive, ●...
  • Page 14 DO NOT PLACE THIS PRODUCT INTO THE WASTE CONTAINER ! This device is marked with a cross-lined waste container symbol according to 2002/96/EU Directive on Waste Electric and Electronic Equipment. Such marking informs that after usage equipment can not be trashed together with other household waste.