Diagnostics
Built-In Error Codes
The thermostat timer digital display is designed to alert you if there is an error or problem in the control.
Example of LED code 2.
X2
X2
X2
X1
X1
X1
flash
flash
pause
If one of the following front burner switch cover LED codes occurs, perform the following to determine the
proper repair:
Note: Use flashing LED for error determination. Interface display only works for 1 burner. You may have up
to 10 flashes before a pause.
LED
Interface
Code
Display
Failure
1
Induction element is not
recognizing a compatible
or
cooking vessel.
Residual heat flashes at 1 Hz
2
Switch
3
Flash failure
4
Incorrect setup data
Configuration error
between interface board
and induction generator
No function or partial
function
5
Communication error
between interface board
and induction generator
© 2009 Viking Preferred Service
Example of LED code 3.
X2
X2
X2
X1
X1
X1
flash
flash
flash
Possible Reason
Pan detection has the higher
priority over residual heat, also
shown when Boost is selected.
Wiring
Operation of switch
Flash failure
Component failure
False configuration of filter
board by interface board
Component error on
interface or filter board
Interface board
Interface board cable loose or
defective
Filter board
X2
X2
X2
X1
X1
X1
flash
flash
pause
Action
Place compatible cooking vessel
on induction element
The surface is hot (60˚C)
Replace or repair as necessary
Replace switch
Replace interface board
Check version of interface board
Replace interface board
If continuous error replace filter
board.
Replace interface board
Check connection of cable and
replace cable if needed
Replace filter board
X2
X2
X2
X1
X1
X1
flash
flash
flash
12
Need help?
Do you have a question about the VICU206 and is the answer not in the manual?
Questions and answers