GENERAL INFORMATION

The central vacuum is designed for dry pick-up of household dirt and
dust. Avoid picking up hard or sharp objects with this system to prevent
hose and plastic pipe damage or clogs.
This manual will cover the final steps of installation of the power unit in
your home. It will also provide the necessary information for maintenance
and trouble shooting, in the unlikely event that it will be needed. If you
require further information about installation or inquires on the product
please contact your local authorized dealer/distributor.
INSTALLATION SAFETY EqUIPMENT
For wall preparations and cover preparations,
safety equipment such as helmet, gloves, goggles
and hearing protection are recommended.
CAUTION
Use caution when drilling holes in walls as gas pipelines and water pipes
and electrical wires may be present.
If you have any questions regarding the product, spare parts, service, warranty
or anything else, please contact your local authorized dealer or distributor.
GROUNDING INSTRUCTIONS
This appliance must be grounded. If it should malfunction or brake down,
grounding provides a path of least resistance for electrical current to reduce
the risk of electrical shock. This appliance is equipped with a cord having
an equipment-grounding conductor and grounding plug. The plug must
be plugged into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
WARNING
Improper connection of the equipment-grounding conductor can result in
electrical shock. Check with a qualified electrician or service person if you are
in doubt as to whether the outlet is properly grounded, or if the outlet does
not fit into an outlet. Do not modify the plug provided with the appliance.
This appliance is for use on a nominal 120 volt circuit and has a grounding
plug that looks like the plug illustrated in Figure A. Make sure that the appliance
is connected to an outlet having the same configuration as the plug.
No adapter should be used with the appliance.
NOTE: In Canada, the use of a temporary adapter
is not permitted by the Canadian Electrical Code.
WARNING
If the supply cord is damaged, it must be replaced by a special cord
available from your local authorized dealer/distributor.
SERVICE INFORMATION
The instructions in this booklet serve as a guide to routine maintenance. For
additional information, contact you're nearest authorized dealer/distributor.
RATING PLATE
The type, model, and serial numbers are indicated on the rating plate
located on the control panel or motor hood. For prompt and complete service
information, always refer to these numbers when inquiring about service.
WARNING
Non-observance of the safety directions may result in bodily harm.
PRODUCT DIMENSIONS
Refer to page 15 - Image 1
WASTE OF ELECTRIC AND ELECTRICAL
EqUIPMENT (WEEE)
This symbol on the product or on its packaging indicates that this product
may not be treated as household waste. Instead it should be handed over
to applicable collection point for the recycling of electronics and electrical
equipment. By ensuring this product is disposed of correctly, you will help
prevent potential negative consequences for the environment and human
health, which could otherwise be caused by inappropriate waste handling
of this product. For more detailed information about this product, please
contact your local waste disposal service or the shop where you purchased
the product.

INSTALLATION

Your home is most likely already fitted with the system of plastic pipes
and inlet valves and you are ready to install the central power unit. If your
home is not fitted for a central vacuum system, you can contract to have
the Kenmore Central Vacuum System installed by a professional by
contacting your local dealer or distributor or choose to do-it-yourself.
The central power unit should be located as far away from the general living
area as possible, yet accessible so you can remove the dirt receptacle, reach
the filter, and inspect the central power unit. A typical location would be in a
garage, where you could vacuum your car or garage area, and where emptying
the dirt receptacle and cleaning the filter would be more convenient. Other suit-
able locations are in the basement, laundry room, or ventilated storage room.
CAUTION
Use caution when drilling holes in walls as gas pipelines and water pipes
and electrical wires may be present. Holes in the masonry are only
allowable if through it its standing stability is not impaired. Holes in wood
studs should be drilled. Depending on what material your home is
built with, use the appropriate anchors to hang your power unit. Power unit
simply slides onto mounting bracket and clicks into place.
Refer to page 15 - Image 3
• Place the central power unit in a place that is removed from the general
living area. The exhaust should be easy to connect to a ventilation pipe.
This can be done regardless of the house's construction material.
• Locate the two low voltage wires near the main pipe. Remove the
insulation from the low volt wire. Insert the low volt wire into the spring
loaded low volt connectors. Be certain you comply with your local
electrical codes and regulations.
Refer to page 15 - Image 4
• Make sure there is a dedicated electric socket for the power unit.
• Plug in your CVS with the supplied power cord.