HCD-HDX285/HDX287WC/HDX585/HDX587WC/HDX589W/HDX685/HDX686W
VERSION DISPLAY
This mode displays the version of the STR/DVD micro controller.
Note: Not used for the servicing.
AUTOMATIC ACOUSTIC FIELD CALIBRATION MICRO-
PHONE TEST MODE
Procedure:
1. Press the [
/
] button to turn the power on.
?
1
2. Insert ECM-AC2 supplied as an accessory into the AUDIO IN/
A.CAL MIC jack.
3. While pressing the [
] and [
x
the [VOLUME] dial in the direction of (–).
4. Confi rm that the following are shown on the display panel.
1 The jack inserted/non-inserted detection display and the
STEREO/MONO detection display.
2 Presence of DIGITAL voice input to the microcomputer.
(OK: input, NG: no input)
3 The value of the MIC input to the micro controller. (shown
"255h")
* * *
* *
1
2
1 "NON" : Not detected
"ST"
: STEREO
"MN"
: MONO
2 OK : input
NG : no input
3 0-255 (Changes in real time)
5. To exit this mode, press two buttons [
ously, turn the [VOLUME] dial in the direction of (–).
DEMO PLAY OUT
It is a mode to release the demonstration reproduct by the dedi-
cated demonstration disc.
Procedure:
1. During playback the DEMO disc, press the [
tons for fi ve seconds simultaneously.
2. The message "DEMO OFF" is displayed, a mode to reproduct
the demonstration is released.
AMP TEST MODE
The examination of the AMP measurement safety standard/tem-
perature characteristic modes can be easily executed by executing
this mode in a short time.
Procedure:
1. Press the [
/
] button to turn the power on.
?
1
2. Press three buttons [
], [
x
N
3. The message "MEASURE" is displayed on the fl uorescent in-
dicator tube and enter the AMP measurement mode.
4. When the [DISPLAY] button on the remote commander is
pressed in the state of step 3, the message "SAFETY" is dis-
played on the fl uorescent indicator tube and enter the AMP
safety standard/temperature characteristic mode.
5. When the [MUTING] button on the remote commander is
pressed in the state of step 3, the message "VOL N" is dis-
played on the fl uorescent indicator tube.
6. When the [MUTING] button on the remote commander is
pressed in the state of step 5, the message "VOL M/M" is
displayed on the fl uorescent indicator tube and enter the vol-
ume MIN/MAX mode. In this mode, the message "VOLUME
MAX" is displayed on the fl uorescent indicator tube when
24
] buttons simultaneously, turn
Z
* * *
3
] and [
] simultane-
x
Z
] and [
] but-
x
N
] and [
] simultaneously.
Z
[VOLUME +] button on the remote commander is pressed,
and the message "VOLUME MIN" is displayed on the fl uores-
cent indicator tube when [VOLUME –] button on the remote
commander is pressed.
7. To exit from this mode, press the [
"COLD RESET" is displayed on the fl uorescent indicator tube
for a while and all the settings are reset.
PROTECTION FACTOR (SD DETECTION/DC DETEC-
TION) IDENTIFICATION TEST MODE
When an error is detected, the fl orescent indicator tube alternately
displays
"PROTECTOR" h "PUSH POWER".
Press the [
/
] button.
?
1
* Buttons other than the [
"STANDBY" blinks three times on the fl orescent indicator tube.
The protection release state (POWER OFF) is established.
(No fl orescent indicator tube display)
Press the [
/
] button twice.
?
1
The power to the system turns on, and the normal operation is es-
tablished. (Restore)
During the protection state:
1. If the AC plug is connected or disconnected during the protec-
tion state, the protection state is released, and the normal op-
eration is established. (The protection state is not maintained)
2. The protection factor is displayed by pressing the button on
the remote commander in order of [RETURN] → [3] → [2] →
[0] → [0] → [ANGLE] during the protection state. (during the
"PROTECTOR" h "PUSH POWER" display)
When SD is detected: Repeats
"SD DETECT" h "PUSH POWER".
When DC is detected: Repeats
"DC DETECT" h "PUSH POWER".
SD detection:
When the "L" output from the SD (shutdown) port on the
S-MASTER POWER Driver Shutdown and voltage descent
(15V or less) of 30V power supply (PVDD) are detected.
DC detection:
When the "L" output from the power/speaker error detection
circuit (DC detection port) is detected for two seconds continu-
ally, the power system other than that of the fl orescent indica-
tor tube is turned off, and the protection state is established.
COLOR SYSTEM CHANGE (HDX285: 240V AC area in E
and Saudi Arabia models only)
This mode let you change the color system of the video output
from PAL to NTSC or vice-versa.
Procedure:
1. Press the [
/
] button to turn the power on.
?
1
2. Press the [FUNCTION] button to select the "DVD".
3. Press the [
/
] button to turn the power off.
?
1
4. Press two buttons [
] and [
.
5. The message "COLOR PAL" or "COLOR NTSC" will be dis-
played on the fl uorescent indicator tube and color system of the
video output is changed.
/
] button. The message
?
1
/
] button are invalid.
?
1
/
] simultaneously.
?
1
Need help?
Do you have a question about the HCD-HDX285 and is the answer not in the manual?
Questions and answers
I **** useing the av cables to my tv but no sound comes through
There may be several reasons why there is no sound from your Sony HCD-HDX285 when using AV cables to connect to your TV:
1. Incorrect Cable Connection – Ensure the AV cables are properly connected to the correct AUDIO OUT jacks on the home theater system and AUDIO IN jacks on the TV.
2. TV Input Selection – Make sure the TV is set to the correct input source that matches the AV connection.
3. Volume and Mute Settings – Check if the volume is turned up on both the home theater system and the TV, and ensure that mute is not enabled.
4. Speaker Connections – Verify that the speakers are properly connected to the home theater system.
5. Audio Output Settings – Ensure the home theater system is set to output audio through the AV cables and not HDMI or other digital outputs.
6. Defective Cables – Try using a different set of AV cables to rule out any cable issues.
7. System Reset – If none of the above steps work, reset the home theater system to factory settings and try again.
If the problem persists, the issue might be with the internal components of the home theater system.
This answer is automatically generated