Hide thumbs Also See for Timy 3:

Advertisement

Version: E140408
Manual
General

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Timy 3 and is the answer not in the manual?

Questions and answers

Summary of Contents for ALGE-Timing Timy 3

  • Page 1 Version: E140408 Manual General...
  • Page 2 Important Information General Before using your ALGE-TIMING device read the complete manual carefully. It is part of the device and contains important information about installation, safety and its intended use. This manual cannot cover all conceivable applications. For further information or in case of problems that are mentioned not at all or not sufficiently detailed, please contact your ALGE-TIMING representative.
  • Page 3: Declaration Of Conformity

    Manual TIMY3 - General Declaration of Conformity We declare that the following products comply with the requirements of the listed standards. ALGE-TIMING GmbH Rotkreuzstrasse 39 A-6890 Lustenau declare under our sole responsibility, that the timing device Timy3 W and Timy3 WP...
  • Page 4 Manual TIMY3 - General Control elements USB-interface Charging socket ALGE multiport Connection for display board Connection for start emitter (C0) Connection for finish emitter (C1) Standard ALGE photocell socket Page 4...
  • Page 5: Table Of Contents

    Manual TIMY3 - General Table of contents Device Description ...................... 7 TIMY3 Models ..................... 7 TIMY3 Software ....................8 Driver Installation ....................8 Keypad ........................ 9 Display of TIMY3 ....................10 Choose Language ..................... 11 Start Up ........................12 Switch On ......................12 Switch Off ......................
  • Page 6 Manual TIMY3 - General 10.4.4 BACK LIGHT ..........................22 10.5 INTERFACE ...................... 23 10.5.1 DISPLAYBOARD ........................... 23 10.5.2 RS232 ............................23 10.5.3 GSM-MODEM ..........................23 10.6 PRINTER ......................23 10.6.1 PRINTER-MODE ........................... 23 10.6.2 PRINT STARTTIME ........................23 10.6.3 AUTO LINE FEED ......................... 24 10.6.4 START-LOGO ..........................
  • Page 7: Device Description

    Manual TIMY3 - General Device Description The ALGE TIMY3 is a handy device, equipped with high-quality technology. During the development, we have paid special attention to the self-evident principles of ALGE- TIMING: ease of operation, extreme reliability and robust design. Latest technology, integrated in a casing especially designed for timing, result in a unique device.
  • Page 8: Timy3 Software

    Speed-Climbing: timing for parallel competitions at speed climbing with false start TV-Timer simple timing program for controlling a display board or TV time flashs 1.3 Driver Installation For installation of drivers, separate manuals are available. You can download them on our or contact your ALGE representative. homepage www.alge-timing.com Page 8...
  • Page 9: Keypad

    Manual TIMY3 - General 1.4 Keypad The TIMY3 has a weather-proof (water-proof) silicone keypad. The keypad is ideal for outdoor use. The keys are raised and have ideal pressure points. Although the TIMY3 is small in di- mensions, they are easy to operate. Control keys: all-purpose keys;...
  • Page 10: Display Of Timy3

    Manual TIMY3 - General 1.5 Display of TIMY3 The TIMY3 has a display with backlight. The backlight makes reading of the display at bad light conditions easier. As the backlight consumes energy it is only switched on automatically when the TIMY3 is connected with an external power supply (e. g. PS12A). If you use the TIMY3 in battery mode you can switch on the backlight in the menu.
  • Page 11: Choose Language

    Manual TIMY3 - General 1.6 Choose Language Currently, you can choose between the following languages: German, English, French and Italian. • Press menu key • Select <GENERAL> or <ALLGEMEIN> with arrow down key • Press OK-key (red or green) • Select <LANGUAGE>...
  • Page 12: Start Up

    Manual TIMY3 - General Start Up 2.1 Switch On • Press „START/ON“ key • Display shows: “Really switch-on? Press the green OK button!“ • If you press the green OK key within 10 seconds, the TIMY3 switches on, other- wise it automatically switches off. 2.2 Switch Off You have got two possibilities to switch off the TIMY3: Method 1:...
  • Page 13 Manual TIMY3 - General Internal supply: The battery compartment has space for 6 batteries type AA or rechargeable batteries. For TIMY3 WP you have to use the heat-sealed rechargeable battery-packs ONLY! Timy3 W Timy3 WP Timy3 -20°C / -4F 20°C / 68F -20°C / -4F 20°C / 68F Alkaline Batteries...
  • Page 14: Printer

    Manual TIMY3 - General Printer TIMY3 WP has an integrated thermal printer. The best paper for the printer is our ALGE paper. It is recognizable by the ALGE logo print on the reverse side, available with your ALGE repre- sentative. 3.1 Change of Paper •...
  • Page 15: Connection Of Auxiliary Devices

    Manual TIMY3 - General Connection of Auxiliary Devices A wide range of devices can be operated with the TIMY3. Please ask your ALGE representative for the possibilities. 5.1 Channels The TIMY3 has 9 independent timing channels. Attention: Channels 0 to 5 have a maximum precision of 1/10 000 seconds but channel 6 to 8 only 1/100 seconds.
  • Page 16: Timy3 Update

    Manual TIMY3 - General TIMY3 Update Please visit our homepage www.alge-timing.com for a free update for your TIMY3 software. 6.1 Update with Cable 205-02 • log into the internet • choose language • click on „download“ in the left column •...
  • Page 17: Update With Usb Cable

    Manual TIMY3 - General 6.2 Update with USB Cable • If not yet done, the TIMY3 USB driver has to be installed. An instruction for this can be found on our homepage. • The TIMY3 USB driver can be found at Download/PC software/Various Software:/Timy USB and Timy2 update •...
  • Page 18: Info Mode

    Manual TIMY3 - General Info Mode Pressing the buttons opens the info mode. Im- portant data is displayed. • external power supply Yes or No Display with external supply • TIMY3 program version • TIMY3 boot version • battery voltage •...
  • Page 19: Menu

    On the following pages the different menu items are described. The program specific menu settings are described in the separately available manuals for each program. Bold printed set- tings are the ALGE-TIMING factory settings. 10.1 CLASSEMENT The ‘classement’ menu offers two different options.
  • Page 20: Change Heat

    Manual TIMY3 - General 10.2.1.1 PRECISION This is for setting the calculation precision. Only for net times! • <1s> calculated times in seconds • <1/10> calculated times in 1/10 seconds • <1/100> calculated times in 1/100 seconds • <1/1000> calculated times in 1/1 000 seconds •...
  • Page 21: Language

    Manual TIMY3 - General 10.2.5 LANGUAGE You can adjust the following languages as defaults for the TIMY3 • <GERMAN> • <ENGLISH> • <FRENCH> • <ITALIAN> • <SPANISH> • <SCHWEDISH> 10.2.6 STANDARD Reset the TIMY3 to the factory defaults. • <STANDARD-SETT> 10.2.7 HARDWARE This menu is only available for our service technicians.
  • Page 22: Beep

    Manual TIMY3 - General 10.3.2 BEEP This switches the channel beep on or off. • <OFF> • <ON> Factory default 10.3.3 TED-RX This activates the multichannel reception by the TED-RX. • <OFF> Factory default • <ON> ATTENTION! If this function is activated the serial interface is occupied by the TED. 10.3.4 CHANNEL-PATTERN This menu is currently not available.
  • Page 23: Interface

    Manual TIMY3 - General 10.5 INTERFACE Settings for the RS232 and scoreboard interface. Some settings are only available in certain programs. 10.5.1 DISPLAYBOARD These are settings for ALGE LED displays. • <CONTRAST> adjusts the brightness (0 – 9) of the LED display board •...
  • Page 24: Auto Line Feed

    Manual TIMY3 - General 10.6.3 AUTO LINE FEED • <0> 0 is standard, enter 0 - 9 10.6.4 START-LOGO • <OFF> • <ON> standard 10.6.5 PRINT DAYTIME • <OFF> • <ON> standard 10.7 PROGRAM This function allows switching to another program. ATTENTION! When changing the program all saved times will be deleted! 10.8 Program Specific Settings Depending on active program this menu item is different.
  • Page 25: Wtn

    Manual TIMY3 - General 10.9 The ALGE WTN is a compact radio system for timing. A radio network consists of several de- vices of the WTN-series. Within the network, devices can communicate with each other using other devices; i.e. the communication is carried out from one device to another through a third one.
  • Page 26: Settings

    Manual TIMY3 - General 10.9.3 SETTINGS • <RADIO POWER> 10 (standard), 25, 50 100 mW • <RS232> OFF, ON (standard) • ↑ only rising, ↑+↓ rising and falling <EDGE> • <WTN-UPDATE> OFF, ON (standard) • <RF-UPDATE> ON, OFF (start with F0 and cancel with F1); at least one participant must be connected •...
  • Page 27: Technical Data

    Manual TIMY3 - General 11 Technical data Processor: Siemens C161 with 3.3 V technology Time reference: 12.8 MHz TCXO or standard quartz Time resolution: 1/10 000 seconds Running precision: Temperature compensated quartz oscillator TCXO: temperature range -25 to 50 °C: ..+/- 2.5ppm (+/- 0.009 sec/h) at aging: ..........
  • Page 28: Pin Assignment

    Manual TIMY3 - General 11.1 Pin Assignment USB-Interface (1): The USB-interface is used as interface between TIMY3 and computer. Via this interface the TIMY3 can complete- ly be controlled and all data can be recalled. Charger Connection (2): ALGE-Multiport (3): Pin assignment: 1 ..
  • Page 29 Manual TIMY3 - General Banana plugs for display board Banana plugs for start channel C0 Banana plugs for stop channel C1 Photocell socket (7) Pin assignment: 1 .... c0 ..start channel 2 .... c1 ..stop channel 3 .... GND..common ground 4 ....
  • Page 30: Interfaces

    Manual TIMY3 - General 12 Interfaces 12.1 RS232 Interface Output format: 1 start bit, 8 data bit, no parity bit, 1 stop bit Bit rate: 9 600 baud factory setting adjustable: 2400, 4800, 9600, 19200, 28800, 38400 Transmission protocol: ASCII yNNNNxCCCxHH:MM:SS.zhtqxGGRRRR(CR) y ........
  • Page 31 Manual TIMY3 - General Page 31...
  • Page 32 Manual TIMY3 - General Page 32...
  • Page 33: Rs485 Interface

    Manual TIMY3 - General 12.2 RS485 Interface This interface is only used for special applications such as wind speed measurement, TIMY3 Terminal etc. 12.3 Interface for Display Board Output format: 1 start-bit, 8 data-bit, no parity-bit, 1 stop-bit factory setting: 2400 baud (necessary for ALGE GAZ display board) Bit rate: 2400, 4800, 9600, 19200, 28800, 38400 Transmission protocol:...
  • Page 34 Manual TIMY3 - General Page 34...
  • Page 35 Manual TIMY3 - General Page 35...
  • Page 36 Manual TIMY3 - General Subject to changes Copyright by ALGE-TIMING GmbH Rotkreuzstr. 39 6890 Lustenau / Austria www.alge-timing.com Page 36...

Table of Contents

Save PDF