Do you have a question about the E 600 and is the answer not in the manual?
Questions and answers
Summary of Contents for Esteam Cleaning Systems E 600
Page 1
MANUFACTURED BY ESTEAM CLEANING SYSTEMS POWERFUL PRODUCTS FOR PROFESSIONAL CLEANING 760-160 Printed in Canada...
Page 2
ESTEAM CLEANING SYSTEMS E600’s OWNER’S MANUAL Congratulations on your selection of a new E600 soil extractor built in Canada by “Esteam Cleaning Systems.” Our goal has been to produce the best high performance line of carpet cleaning equipment on the market today. Reading your owners’...
TABLE OF CONTENTS Page No. Introduction to the E600 Specifications Maintenance Safety Information Operating Instructions Trouble Shooting Schematic Diagram Warranty Registration Warranty...
Page 4
INTRODUCTION Only the highest quality components go into our equipment, to deliver you strength and reliability in a long life, high performance machine. The E600’s housing is made of high impact, unbreakable polyethylene. We are so confident in the housing that we put a lifetime warranty on this unit. The E600’s incorporate a unique 3 stage vacuum system to produce 125 inches of water lift.
SPECIFICATIONS E600’s ELECTRICAL Single Cord 115 volt AC 15. Amp VACUUMS 3 Stage vacuum motor PUMP 100 PSI diaphragm demand pump OPTIONAL HEATER Boosts water temp. to 200ºF VACUUM LIFT 125” of water lift SOLUTION TANK CAPACITY 6 gallons (clean water) RECOVERY TANK CAPACITY 6 gallons LENGTH...
MAINTENANCE DAILY: - Clean high-level water shut off screen inside recovery tank. - Ensure automatic shut off float ball is working properly. - Rinse out recovery tank after use. - Clean dirt and obstructions from the (recovery tank) drain valve rubber gaskets to prevent premature wear.
SAFETY INFORMATION Prior to inspection or repair of this machine, disconnect all electrical cords rendering the machine powerless. Failure to do so could result in serious or fatal injury. Inspect unit daily for worn or damaged components e.g. frayed cord, loose plug, or a plug with missing ground pin, etc.
OPERATING INSTRUCTIONS Premix cleaning solution with hot water in a 20 litre pail. Pour mixed solution in solution tank of unit. NOTE: Do not mix more solution than you will need for the job. Connect vacuum and solution hoses to unit. Insert plug into 3 pin grounded outlet.
Page 10
OPERATING INSTRUCTIONS (CONTINUED) When the job is completed, empty and rinse out the solution and recovery tanks. Allow vacuum to run for 3 to 5 minutes. This will eliminate all moisture from vacuums assuring long vacuum life. WARNING: When using electrical equipment around water, it is important to wear rubber-soled shoes and keep machine properly grounded at all times.
TROUBLE SHOOTING WARNING: Prior to inspection or repair of this machine, disconnect all electrical cords rendering the machine powerless. Failure to do so could result in serious or fatal injury. PROBLEM CAUSE SOLUTION 1. Entire unit will not 1. Unit not plugged in 1.
Page 12
TROUBLE SHOOTING (CONTINUED) PROBLEM CAUSE SOLUTION 4. Pump runs but does 1. Out of solution 1. Fill will solution not pump solution 2. Pump inlet screen 2. Clean inlet screen plugged 3. Pump was not properly 3. Prime pump using primed priming hose 4.
Page 13
TROUBLE SHOOTING (CONTINUED) PROBLEM CAUSE SOLUTION 6. Vacuums operate but 1. Recovery tank full 1. Drain recovery tank have poor or no suction 2. Vacuum hose plugged 2. Remove blockage 3. Wand plugged 3. Remove blockage 4. Exhaust port blocked 4.
Page 14
TROUBLE SHOOTING (CONTINUED) PROBLEM CAUSE SOLUTION 10. Water accumulating 1. Inside solution line 1. Immediately shut unit in bottom electrical leaking down. Bring unit to a component area dealer for service 2. Pump leaking 2. Immediately shut unit down. Bring unit to a dealer for service 3.
Page 20
PART NO. DESCRIPTION NOTES: 263-007 HP Hose 12” 263-008 HP Hose 18” 305-210 Toggle Switch 305-225 Switch Plate ON/OFF 305-230 Switch, Rocker 20 Amp 315-015 Cord, 25' Black 14/3 SJTW-A 320-110 Lamp, Panel 110v E600-10 320-900 Lamp, Panel 220v E600-20-10 333-005 Fan Muffin 4”...
Page 21
490-002 Heater Mate Foamed Casing 110V E600-10 490-003 Heater Mate Foamed Casing 220V E600-20-10 495-430 Handle E600 (NBLK) 495-435 Sol Tank E600 (NBLK) 495-440 Rec Tank E600 (NB) 498-055 Plug, 1/2 Nylon Not shown 498-060 Plug, 3/4 Nylon Not shown 511-100 Pump, 100 PSI, 110v E600-10...
Page 23
8000 PUMP TROUBLE SHOOTING GUIDE TROUBLE PROBABLE CAUSE TO CORRECT Pump starts but no 1. Not enough volt 1. Provide correct volt prime 2. No liquid 2. Fill liquid 3. Leak in inlet line 3. Correct leak 4. Air lock 4.
Page 24
8000 PUMP TROUBLE SHOOTING GUIDE TROUBLE PROBABLE CAUSE TO CORRECT Pump will not start 1. Bad motor 1. Replace 2. Bad rectifier 2. Replace motor 3. Bad wire connection 3. Correct connection 4. Bad micro switch 4. Replace 5. Bad brushes 5.
Page 26
INTERNAL HEATER MATE (490-002/490-003) PART NO. DESCRIPTION NOTES: 305-245 Thermo Cut-Out 305-265 Themostat 200F 318-005 Heater Element 1850W 110V Use For 490-002 318-900 Heater Element 1850W 220V Use For 490-003 325-005 Connector, Butt - Blue 325-120 Spade, 3/16 F - Blue 325-230 Terminal Ring, #10 - Blue 325-500...
ESTEAM® CLEANING SYSTEMS E-Series Extractor Warranty E1700, E1000, E600, E250 NOTICE: REVIEW THIS WARRANTY CAREFULLY AS THIS DOCUMENT CONTAINS LIMITATIONS AND EXCLUSIONS. PART I: Esteam Manufacturing Ltd. (hereinafter referred to as "Esteam") warrants each new E-Series Extractor, subject to the limitations as defined in the specific details of its warranty coverage defined below.
Page 32
PART III - LIMITATIONS ON WARRANTY COVERAGE WHAT IS NOT COVERED: Notwithstanding any other term or covenant of Esteam contained herein, the following provisions shall apply: No warranty is provided for any Esteam product which has failed as a result of freezing, fire, misuse, alteration, improper amps or voltage, accidental damage, improper maintenance, unauthorized repairs, alterations, abuse, neglect or operation of a Esteam product not expressly recommended or contemplated by Esteam;...
Page 33
PART V - RETURN GUIDELINES Defective items must be replaced through a local Esteam Distributor. Replacement parts will be sent via prepaid regular ground service to the distributor. The defective part must be returned F.O.B. factory within 30 days including a letter providing the machine's serial number, date of purchase, material return authorization number, and customer name.
Page 34
Pumps: All pumps require daily flushing with clean water after use. Internal Heatermate: The internal heater must be flushed with clean water after every use. Any build up of hard water deposits or chemical build up within the internal heater will void any Esteam warranty thusly exclude any liability of Esteam.
Need help?
Do you have a question about the E 600 and is the answer not in the manual?
Questions and answers