INSTALLATION AND OPERATING INSTRUCTIONS
LEAVE THIS DOCUMENT WITH THE HOUSEHOLDER!
Water
Control System:
Fireplace & Chimney:
Clearance:
Extended Burn:
MAXIMUM PERFORMANCE With door closed,
burning dry fuel with flue draught of 14Pa
Mean CO in flue (as if at 13% O2):
Maximum achieved at refuelling interval of:
* NOTE: Figures are for heat from the appliance only. There will typically be additional, often substantial, heat gains
from the masonry of the fireplace and chimney, and consequent higher total efficiency. Total performance for a
particular building can be calculated by the method of EN13384
This document, when completed by the installer, constitutes a 'Hearth Notice' for purposes of the England and Wales
Building Regulations 2000, (App. Doc. J4). It must be left with the householder and placed where it can easily be found.
APPLIANCE SERIAL NUMBER:
INSTALLED AT LOCATION:
BY:
EMERGENCY TELEPHONE:
SIGNED:
Who certifies that this installation is safe, has been demonstrated to the householder,
conforms with current building regulations and with these instructions
TO FIND A QUALIFIED INSTALLER, FUEL SUPPLIER or CHIMNEY SWEEP, CONTACT:
UK: The Solid Fuel Association, 7 Swanwick Court, Alfreton, Derbyshire DE55 7AS Tel:0845-601-4406 www.solidfuel.co.uk
RoI: Irish Nationwide Fireplace Organisation, 162 Capel Street, Dublin 1 Tel:01-801-5959 www.fireplace.ie
For use only with open-vented, indirect, water systems. Maximum pressure 2 bar. Can be
inter-connected with combi boilers & other heat systems using Esse Centraliser Unit.
All-mechanical thermostatic air supply to fire in response to boiler temperature. No electrical
connections or parts. Can be controlled by time clocks, room thermostat etc.
For installation in masonry fireplace with a single dedicated chimney.
Minimum flue draught 14Pa
Physical space: 100mm around in-room parts. From combustibles: 225mm
Variable with fuel, heat demand and chimney conditions. Anthracite = c12 hrs
Mean flue temperature: *
Flue gas flow:
Efficiency: *
Total output from appliance: *
Output to room:
Output to water:
Fuel per hour at maximum:
Manufactured by: Esse Engineering Ltd
Long Ing, Barnoldswick, Lancashire
DATE:
BIOMASS / MINERAL FUEL
FIREPLACE INSET ROOMHEATER
WITH THERMOSTATIC BOILER
Biomass (Wood Logs)
(With type 395 Boiler)
395 ºC
8.52 g/sec
0.4%
75.7 %
14.7 kW (50,443 Btu)
3.6 kW (12,437 Btu)
11.1 kW (38,006 Btu)
3.8 kg
1 hr
BB18 6BN,
www.esse.com
1
Mineral Fuel ('Ancit')
(With type 395 Boiler)
364 ºC
13.6 g/sec
0.12%
72.7 %
14.6 kW (49,802Btu)
2.8 kW (9,714Btu)
11.8 kW (40,088Btu)
2.4 kg
2hr
England
Flue Draught
measured on
commissioning:
Pa
Fuel used on
commissioning