Panasonic WH-MDF09C3E5 Operating Instructions Manual

Panasonic WH-MDF09C3E5 Operating Instructions Manual

(mono bloc) air-to-water heatpump system
Hide thumbs Also See for WH-MDF09C3E5:

Advertisement

ENGLISH
ENGLISH
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Before operating the unit, make sure the installation has been carried out correctly by authorized dealer correctly and
precisely following the installation instructions given.
FRANÇAIS
FRANÇAIS
Avant d'utiliser l'appareil, lisez ce mode d'emploi dans son intégralité et conservez-le pour toute référence ultérieure.
Avant de faire fonctionner l'unité, assurez-vous que l'installation a été correctement réalisée par un revendeur agréé
et dans le strict respect des consignes d'installation fournies.
ESPAÑOL
Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como
futuro elemento de consulta.
Antes de operar la unidad asegúrese de que la instalación haya sido realizada correctamente por un instalador
autorizado, siguiendo de forma correcta y precisa las instrucciones de instalación dadas.
DEUTSCH
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie
sie für die künftige Verwendung auf.
Vor der Inbetriebnahme dieses Geräts ist sicherzustellen, dass die Montage durch einen autorisierten Händler
fachgerecht entsprechend der Installationsanleitung durchgeführt wurde.
ITALIANO
Prima di utilizzare l'unità si prega di leggere attentamente le istruzioni e di conservare questo opuscolo per potervi
fare riferimento in futuro.
Prima di far funzionare l'unità, assicurarsi che l'installazione sia stata eseguita correttamente da un rivenditore
autorizzato e seguendo precisamente le istruzioni date per l'installazione
NEDERLANDS
Lees voor u het apparaat gebruikt deze gebruiksaanwijzing grondig en bewaar deze voor toekomstig gebruik.
Controleer, voor u de unit in gebruik neemt, dat de installatie goed is uitgevoerd door een offi ciële dealer en dat dat
nauwkeurig is gedaan volgens de verstrekte instructies voor de installatie.
PORTUGUÊS
Antes de ligar a unidade, leia cuidadosamente este manual de utilização e guarde-o para futura referência.
Antes de colocar a unidade em funcionamento, ceritifque-se que a instalação foi feita correctamente por um
fornecedor autorizado e que seguiu com precisão as instruções de instalação dadas.
EΛΛΗΝΙΚΆ
Προτού θέσετε τη μονάδα σε λειτουργία, διαβάστε προσεκτικά αυτές τις οδηγίες χρήσης και φυλάξτε τις για μελλοντική αναφορά.
Πριν θέσετε σε λειτουργία τη μονάδα, βεβαιωθείτε ότι η εγκατάσταση έχει διεξαχθεί κανονικά από εξουσιοδοτημένο
αντιπρόσωπο, ο οποίος έχει ακολουθήσει σωστά και πιστά τις δοθείσες οδηγίες.
БЪЛГАРСКИ
БЪЛГАРСКИ
Преди да задействате климатика, прочетете внимателно инструкциите за употреба и ги запазете за бъдещи справки.
Преди да използвате устройството се уверете, че монтажът е извършен правилно и прецизно от оторизиран дилър,
като са спазвани инструкциите за монтаж.
© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2010.
Unauthorized copying and distribution is a violation
of law.
(Mono bloc) Air-to-Water Heatpump System

Operating Instructions

Model No.
Mono bloc Unit
WH-MDF09C3E5
WH-MDF12C6E5
WH-MDF14C6E5
WH-MDF16C6E5
2 ~ 9
2 ~ 9
10 ~ 17
10 ~ 17
18 ~ 25
18 ~ 25
26 ~ 33
26 ~ 33
34 ~ 41
34 ~ 41
42 ~ 49
50 ~ 57
58 ~ 65
66 ~73
66 ~73
F567560

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic WH-MDF09C3E5

  • Page 1: Operating Instructions

    Преди да задействате климатика, прочетете внимателно инструкциите за употреба и ги запазете за бъдещи справки. Преди да използвате устройството се уверете, че монтажът е извършен правилно и прецизно от оторизиран дилър, като са спазвани инструкциите за монтаж. © Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2010. Unauthorized copying and distribution is a violation of law.
  • Page 2: Safety Precautions

    SAFETY PRECAUTIONS Thank you for purchasing • Panasonic (Mono bloc) Air-to-Water Heatpump is a system designed Panasonic Product for combination with Panasonic Tank Unit. In case of non-Panasonic Tank Unit is being used with Panasonic (Mono bloc) Air-to-Water Heatpump System, Panasonic cannot guarantee neither good...
  • Page 3 WARNING WARNING CAUTION CAUTION POWER SUPPLY MONO BLOC UNIT Do not use modifi ed cord, Do not install the unit close to any combustible joint cord, extension cord or equipment or at bathroom. Otherwise, it may unspecifi ed cord to prevent cause electric shock or fi...
  • Page 4: Remote Control

    REMOTE CONTROL • Some functions described in this manual may not be applicable to your unit. • Consult your nearest authorized dealer for further information. ERROR PUMPDW RESET FORCE • For normal operation, the buttons are not in use. TIMER OUTDOOR ACTUAL HEAT...
  • Page 5 SETTING UP THE SPECIAL FUNCTIONS SETTING UP THE SPECIAL FUNCTIONS • After initial installation, you can manually adjust the settings. The initial setting remains active until the user changes it. • The remote control can be used for multiple installations. Some functions may not be applicable to your unit. •...
  • Page 6: Basic Operation

    BASIC OPERATION ADVANCE OPERATION • It is strongly recommended to contact the nearest OFF / ON authorized dealer to change the water temperature range. TO TURN ON OR OFF THE UNIT • Using the remote control could set the temperature range for water outlet temperature and outdoor ambient •...
  • Page 7: Weekly Timer Setting

    WEEKLY TIMER SETTING Timer Display Lights up if Timer 6 different programs can be set in a day (1 ~ 6) operation is selected TIMER SETTING 2 3 4 5 6 Indicates the selected day TIMER MONTUEWEDTHU FRI SAT SUN Indicates the next timer operation day OFF/ON SELECT...
  • Page 8 MONO BLOC UNIT MONO BLOC UNIT In case of a power supply failure or pump operating failure, drain the system (as suggested in the fi gure below). <H When water is idle inside the system, freezing up is very likely to happen which could damage the system. •...
  • Page 9: Troubleshooting

    TROUBLESHOOTING The following symptoms do not indicate malfunction. The following symptoms do not indicate malfunction. SYMPTOM SYMPTOM CAUSE CAUSE Flowing sound during operation. ► • Refrigerant fl ow inside the unit. Operation is delayed a few minutes after restart. ► • The delay is a protection to the unit’s compressor. Mono bloc unit emits water/steam.
  • Page 10 INFORMATION/INFORMATIONS/INFORMACIÓN/ INFORMATIONEN/INFORMAZIONI/ INFORMATIE/ INFORMAÇÃO/ΠΛΗΡΟΦΟΡΙΕΣ/ИНФОРМАЦИЯ Information for Users on Collection and Disposal of Old Equipment These symbols on the products, packaging, and/or accompanying documents mean that used electrical and electronic products should not be mixed with general household waste. For proper treatment, recovery and recycling of old products, please take them to applicable collection points, in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC.
  • Page 11 Benutzerinformation zur Sammlung und Entsorgung von veralteten Geräten Diese Symbole auf den Produkten, Verpackungen und/oder Begleitdokumenten bedeuten, dass benutzte elektrische und elektronische Produkte und Batterien nicht in den allgemeinen Hausmüll gegeben werden sollen. Bitte bringen Sie diese alten Produkte und Batterien zur Behandlung, Aufarbeitung bzw. zum Recycling gemäß...
  • Page 12 свържете се с местните органи на властта или вашия доставчик, за да получите информация за тяхното коректно изхвърляне. Pursuant to at the directive 2004/108/EC, article 9(2) Panasonic Testing Centre Panasonic Service Europe, a division of Panasonic Marketing Europe GmbH Winsbergring 15, 22525 Hamburg, F.R. Germany...

This manual is also suitable for:

Wh-mdf12c6e5Wh-mdf14c6e5Wh-mdf16c6e5

Table of Contents