Alpha-InnoTec SWC 140H Operating Manual

Alpha-InnoTec SWC 140H Operating Manual

Swc – series
Table of Contents

Advertisement

operating manual
UK
Brine/Water
CompaCt
Heat pumps
SWC – Series
We reserve the right to modify technical specifications without prior notice.
UK830300/170717
© Alpha-InnoTec GmbH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SWC 140H and is the answer not in the manual?

Questions and answers

Summary of Contents for Alpha-InnoTec SWC 140H

  • Page 1 Brine/Water CompaCt Heat pumps SWC – Series We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 2: Please Read First

    Failure to observe this information could manufacturer. result in material damage. notiCe. emphasized information. Reference to other sections of the operating manual. Reference to other instructions of the manufac- turer. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 3: Table Of Contents

    SAfeTy ...................... 4 TecHNIcAl dATA/Scope of delIveRy cUSTomeR SeRvIce ................5 SWc 60H(/K) – SWc 120H(/K) ..........24 SWc 140H(/K) – SWc 330(/K) ..........26 WARRANTy / GUARANTee .............. 5 peRfoRmANce cURveS dISpoSAl ....................5 Heating capacity/cop / power consumption / free compression SWc 60H(/K) ..................28...
  • Page 4: Intended Use

    The unit bears the ce mark of conformity. ec declaration of conformity We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 5: Customer Service

    When decommissioning the unit, always comply with applica- ble laws, directives and standards for the recovery, recycling and disposal of materials and components of cooling units. “dismantling”. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 6: Functioning Principle Of The Heat Pump System

    Taking into consideration the ambient conditions, limits of application and the applicable regulations, every heat pump can be utilized in new or existing heating systems. overview “Technical data/scope of delivery”. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 7: Cooling Function

    • The outdoor temperature release set at the heat pump and heating regulator must be exceeded. operating manual of the heat pump and heating regulator. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 8: Care Of The Unit

    Danger! Service and repair work on the components of the unit may be performed only by cus- tomer service personnel authorized by the manufacturer. overview “customer service”. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 9: Scope Of Delivery

    “Technical data/scope of delivery”, “Gen- note the model. eral unit data” section. overview “Technical data/scope of delivery” or rating plate on unit. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 10: Installation

    Caution. follows: Do not tilt the unit more than a maximum of 45° (in any direction). • Tip the unit slowly and carefully to one side… Caution. never tilt the unit more than a maximum of 45°. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 11: Installation Of The Hydraulic Connections

    Caution. When installing the connections, always secure the connections on the unit from twisting, in order to prevent damage to the copper pipes in the interior of the unit. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 12 3 Heat source inflow (return flow) 4 Heat source outflow (forward flow) A straight or extended hose arrangement for the vibration decoupler is not permitted. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 13: Insulating The Hydraulic Connections

    They must be integrated in the heating circuit on-site in compli- ance with the applicable standards and directives. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 14: Electrical Connections

    (inside the unit on the left)… 1 cable duct size 1: 2 cable duct size 2: 1 Size 1: Switch cabinet closed. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 15 Install electrical connections according to the ter- minal diagram and the circuit diagrams… „Terminal diagrams” and “circuit diagrams” for the respective model. Danger! install electric connections only according to the terminal diagram and the circuit dia- grams that apply to your model. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 16: Rinsing And Filling The Unit

    6 circulating pump for heat source 7 circulating pump for heating circuit 8 fill/empty cock for heat source 9 expansion vessel for heat source 10 fill/empty cock for heating circuit We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 17: Rinsing And Filling The Heat Source

    BLEEdING THE HEAT SOURCE FOR A UNIT wITHOUT COOLING FUNCTION bleeding is conducted automatically by means of the inte- grated bleeding function in the safety component. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 18: Bleeding The Heat Source For A Unit With Cooling Function

    Set the overflow valve so that the spread between the for- ward and return flow is ≤ 10K (set at the factory to 200 mbar and sealed by paint). We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 19: Installation Of The Heat Pump And Heating Regulator

    We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 20: Installation Of The Room Thermostat For The Cooling Function

    (and vice versa). notiCe: always comply with the applicable standards and directives. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 21: Hot-Water Tank

    (forward flow). The 3-way switching valve is an accessory and is not in- cluded in the scope of delivery. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 22: Commissioning

    Germany: Send completion report for heat pump systems to the manufacturer’s local partner. overview “customer service”. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 23: Dismantling

    Collect anti-freeze mixture and dispose of properly. Danger! only qualified cooling system technicians are allowed to dismantle the unit and its compo- nents. Caution. recycle or provide for proper disposal of unit components, refrigerants and oil in accord- ance with the applicable regulations, stand- ards and directives. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 24: Technical Data/Scope Of Delivery

    • yes — no Vibration decouplers Heating circuit ı heat source scope of delivery: • yes — no UK813196 *) comply with local regulations n.n. = not detectable We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 25 • • • • • • ı • • ı • • ı • • ı • • ı • 813169-a 813190 813170-a 813171-a 813172-a We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 26: Swc 140H(/K) - Swc 330(/K)

    • yes — no Vibration decouplers Heating circuit ı heat source scope of delivery: • yes — no UK813196 *) comply with local regulations n.n. = not detectable We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 27 SWC 140H(/K) SWC 170H(/K) SWC 230(/K) SWC 330(/K) • ı — ı — • ı — ı — • ı — ı — • ı — ı — • ı — • ı — • ı — • ı —...
  • Page 28: Performance Curves

    Free compression, heating circuit / free compression, heating circuit with cooling ∆p„ / ∆p„† Free compression, heat source / free compression, heat source with cooling We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 29: Swc 70H(/K)

    Free compression, heating circuit / free compression, heating circuit with cooling ∆p„ / ∆p„† Free compression, heat source / free compression, heat source with cooling We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 30: Swc 80H(/K)

    Free compression, heating circuit / free compression, heating circuit with cooling ∆p„ / ∆p„† Free compression, heat source / free compression, heat source with cooling We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 31: Swc 100H(/K)

    Free compression, heating circuit / free compression, heating circuit with cooling ∆p„ / ∆p„† Free compression, heat source / free compression, heat source with cooling We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 32: Swc 120H(/K)

    Free compression, heating circuit / free compression, heating circuit with cooling ∆p„ / ∆p„† Free compression, heat source / free compression, heat source with cooling We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 33: Swc 140H(/K)

    SWC 140H(/K) Qh (kW) Temp„ (°C) Pe (kW) 35°C 50°C 65°C Temp„ (°C) Temp„ (°C) ∆p (bar) ∆p (bar) “„[m3/h] “”[m3/h] p„ p„† p” p”† 823004 Legende: DE823000L “” Volumenstrom Heizwasser “„ Volumenstrom Wärmequelle Temp„ Temperatur Wärmequelle Heizleistung...
  • Page 34: Swc 170H(/K)

    Free compression, heating circuit / free compression, heating circuit with cooling ∆p„ / ∆p„† Free compression, heat source / free compression, heat source with cooling We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 35: Swc 230(/K)

    Free compression, heating circuit / free compression, heating circuit with cooling ∆p„ / ∆p„† Free compression, heat source / free compression, heat source with cooling We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 36: Swc 330(/K)

    Free compression, heating circuit / free compression, heating circuit with cooling ∆p„ / ∆p„† Free compression, heat source / free compression, heat source with cooling Condensers We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 37 We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 38: Size 1: Dimensional Drawings

    Heat source outflow (forward flow) DIN ISO 228 SWC 60… to SWC 100…: G1"AG SWC120… to SWC 170…: G1¼"AG Ducts for electric/sensor cables Safety components We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 39: Size 1: Clearance Dimensions

    Unit installation on sylomer strips Top edge of finished floor Distance to next lateral object ≥ 20 Shaded area = free space for service purposes We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 40: Size 2: Dimensional Drawings

    Heat source outflow (forward flow) DIN 2999 R1½"AG Ducts for electric/sensor cables Safety components Attention! Included in scope of delivery: 4 x compensator DN 40, Rp 1½"IG DIN 2999 We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 41: Size 2: Clearance Dimensions

    In the event of offset mounting of the compensators the dimension 400 can be reduced to ≥ 250. The bracket must be provided by the customer. We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 42: Terminal Diagram

    14-17 kW: C16 A 14-17 kW: C16 A 3~PE/400V/50Hz 6-12 kW: C10 A 14-17 kW: C16 A 14-17 kW: C16 A 1~N/PE/230V/50Hz B10 A ZUP/ZIP ZW2/SST We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 43: Swc 230(/K) - Swc 330(/K)

    SWC 230(/K) – SWC 330(/K) 23kW: C16 A 3~PE/400V/50Hz 33kW: C25 A 33kW: C25 A 1~N/PE/230V/50Hz B10 A ZUP/ZIP ZW2/SST We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 44: Swc 60H(/K) - Swc 80H(/K)

    SWC 60H(/K) – SWC 80H(/K) Circuit diagram 1/2 We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 45 Circuit diagram 2/2 SWC 60H(/K) – SWC 80H(/K) -R12 We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 46: Swc 100H(/K) - Swc 170H(/K)

    SWC 100H(/K) – SWC 170H(/K) Circuit diagram 1/2 We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 47 Circuit diagram 2/2 SWC 100H(/K) – SWC 170H(/K) -R12 We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 48: Swc 230(/K)

    SWC 230(/K) Circuit diagram 1/2 We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 49 Circuit diagram 2/2 SWC 230(/K) -R12 We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 50: Swc 330(/K)

    SWC 330(/K) Circuit diagram 1/2 We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 51 Circuit diagram 2/2 SWC 330(/K) -R12 We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 52: Ec Declaration Of Conformity

    SWC 80H/K 100 271 SWC 100H 100 262 SWC 100H/K 100 272 SWC 120H 100 263 SWC 120H/K 100 273 SWC 140H 100 264 SWC 140H/K 100 274 SWC 170H 100 265 SWC 170H/K 100 275 SWC 230 100 266...
  • Page 53: General Checklist

    Sending the completion report is also a request for a technician authorized by the manufacturer to commission your heat pump. FAZ-WP Formblatt UK820522c Stand: 240407 We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 55: Completion Report For Heat Pump Systems

    Completion report for heat pump systems in De: to the Alpha-InnoTec customer service department +49 (0) 9228 9906 199 in at: to the Alpha-InnoTec customer service department +43 (0) 732 24 42 01 4 in CH: to the Alpha-InnoTec customer service department...
  • Page 57: Notes

    We reserve the right to modify technical specifications without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...
  • Page 58: Customer Service

    +42 (0) 545 24 20 90 fax: +55 (0) 41 301 566 59 e-mail: info@alphatec.cz e-mail: otto@thermacqua.com.br www.alpha-innotec.cz www.thermacqua.com.br ASAp energy vertretung Alpha-InnoTec Schweiz damgade 34 calmotherm AG 6400 Sønderborg Industriepark Tel.: +45 (0) 74 4304 80 6246 Altishofen fax: +45 (0) 74 4304 81 Tel.: +41 (0) 62 74820 00...
  • Page 59 170408 SIA „evA-SAT“ Krasta iela 44 1003 Riga Tel.: +371 (0) 75 054 80 fax: +371 (0) 75 053 99 e-mail: armands.c@evasat.lv www.evasat.lv We reserve the right to modify this document without prior notice. UK830300/170717 © Alpha-InnoTec GmbH...

Table of Contents