GE JSP26 Installation Instructions Manual page 8

30" electric slide-in range
Hide thumbs Also See for JSP26:
Table of Contents

Advertisement

ELECTRICAL CONNECTIONS
3-WIRE POWER CORD
3
INSTALLATION
WARNING:
ground wire of the power cord must be
connected to the neutral terminal located
in the center of the terminal block. The
power leads must be connected to the
lower left and the lower right terminals
of the terminal block.
A
Remove the 3 lower terminal screws from
the terminal block. Insert the 3 terminal
screws through each power cord terminal
ring and into the lower terminals of the
terminal block. Be certain that the center
wire (white/neutral) is connected to the
center lower position of the terminal block.
Tighten screws securely into the terminal
block.
DO NOT remove the ground strap
connection.
Fig. 15
Ground
plate
Power cord
Re-install the junction block access cover
B
making sure that wires do not become
pinched between wire cover and
mainback.
Installation Instructions
The neutral or
Terminal
block
(appearance
may vary)
Neutral
terminal
Ground
strap
(CONT.)
4-WIRE POWER CORD
4
INSTALLATION
WARNING:
the supply circuit must be connected to
the neutral terminal located in the lower
center of the terminal block. The power
leads must be connected to the lower
left and the lower right terminals of the
terminal block. The 4th grounding lead
must be connected to the frame of the
range with the ground plate and the
ground screw.
Remove the 3 lower terminal screws from
A
the terminal block. Remove the ground
screw and ground plate and retain them.
B
Cut and discard the ground strap.
DO NOT DISCARD ANY SCREWS.
Insert the one ground screw into the
C
power cord ground wire terminal ring,
through the ground plate and into the
frame of the range.
D
Insert the 3 terminal screws (removed
earlier) through each power cord terminal
ring and into the lower terminals of the
terminal block. Be certain that the center
wire (white/neutral) is connected to the
center lower position of the terminal block.
Tighten screws securely into the terminal
block.
Before
Fig. 16a
Terminal
block
Ground strap
After
Fig. 16b
Terminal
block
Ground
screw
E
Re-intall the junction block access cover
making sure that wires do not become
pinched between wire cover and
mainback.
8
8
The neutral wire of
Ground strap
or
Neutral
terminal
Neutral terminal
Ground
plate
(grounding
to range)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jss16Jsc26Rs734Rs504Jss26Jsp39 ... Show all

Table of Contents