Dyna-Glo DELUX User's Manual And Operating Instructions

Dyna-Glo DELUX User's Manual And Operating Instructions

Propane construction heater

Advertisement

USER'S MANUAL AND OPERATING INSTRUCTIONS
Dyna-Glo™DELUX
MODELS:
Dyna-Glo™Pro
MODELS:
C
ANS Z83.7-2011 CSA 2.14-2011
adequate ventilation must be provided.
GENERAL HAZARD WARNING
Failure To CoMply wiTh The preCauTionS and inSTruCTionS provided wiTh
ThiS heaTer, Can reSulT in deaTh, SeriouS Bodily injury and properTy loSS,
or daMage FroM The hazardS oF Fire, exploSion, Burn. aSphyxiaTion, CarBon
Monoxide poiSoning, and/or eleCTriCal ShoCk.
only perSonS who Can underSTand and Follow The inSTruCTionS Should
uSe or ServiCe ThiS heaTer.
iF you need aSSiSTanCe or heaTer inForMaTion SuCh aS an inSTruCTion
Manual, laBelS, eTCeTera, ConTaCT The ManuFaCTurer.
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 877-447-4768 8:30 a.m. – 4:30 pm CST, Monday – Friday
50-10-104
RMC-FA40DGD
RMC-FA50DGD
RMC-FA60DGD
RMC-FA100DGD
RMC-FA125DGD/LPFA125DGD (70,000/125,000 BTU/HR, FORCED - AIR)
RMC-FA150DGD
RMC-FA40/DGP/DGP-01
RMC-FA50/DGP/DGP-01
RMC-FA60/DGP/DGP-01
RMC-FA100/DGP/DGP-01
RMC-FA125/DGP/DGP-01
LPFA125H/LPFA125H-01
RMC-FA150/DGP/DGP-01
US
GHP Group, Inc.
6440 w howard St
niles, il 60714-3302
CONSUMER: retain this manual for future reference.
or email us at customerservice@ghpgroupinc.com
PROPANE
CONSTRUCTION HEATER
(40,000 BTU/HR,
(30,000/50,000 BTU/HR,
(30,000/60,000 BTU/HR,
(70,000/100,000 BTU/HR, FORCED - AIR)
(120,000/150,000 BTU/HR, FORCED - AIR)
(40,000 BTU/HR,
(30,000/50,000 BTU/HR,
(30,000/60,000 BTU/HR,
(70,000/100,000 BTU/HR, FORCED - AIR)
(70,000/125,000 BTU/HR, FORCED - AIR)
(120,000/150,000 BTU/HR, FORCED - AIR)
FA60DGP/DGP-01
www.ghpgroupinc.com
Printed in China
FORCED - AIR)
FORCED - AIR)
FORCED - AIR)
FORCED - AIR)
FORCED - AIR)
FORCED - AIR)
FA40DGP-01
LPFA125H/H-01
Rev. 2013-06-05

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DELUX and is the answer not in the manual?

Questions and answers

Summary of Contents for Dyna-Glo DELUX

  • Page 1 PROPANE CONSTRUCTION HEATER USER’S MANUAL AND OPERATING INSTRUCTIONS Dyna-Glo™DELUX RMC-FA40DGD (40,000 BTU/HR, FORCED - AIR) RMC-FA50DGD (30,000/50,000 BTU/HR, FORCED - AIR) MODELS: RMC-FA60DGD (30,000/60,000 BTU/HR, FORCED - AIR) RMC-FA100DGD (70,000/100,000 BTU/HR, FORCED - AIR) RMC-FA125DGD/LPFA125DGD (70,000/125,000 BTU/HR, FORCED - AIR)
  • Page 3: Table Of Contents

    PROPANE CONSTRUCTION HEATER TABLE OF CONTENTS Introduction & Specifications ..........3 •...
  • Page 4: Introduction & Specifications

    PROPANE CONSTRUCTION HEATER Dyna-Glo ProPane ForceD air construction Heaters The heater is designed and approved for use as a construction heater under anS z83.7 CSa 2.14. it is hard CHECK WITH YOUR LOCAL FIRE SAFETY to anticipate every use which may be made of this heater.
  • Page 5: General Safety Instructions

    PROPANE CONSTRUCTION HEATER General saFety instruction accidents are always tragic especially because so many of them could have been prevented with little care and judgment. There are some basic good practices, we hope you will follow for safe use of your heater. iMPortant saFety instruction •...
  • Page 6: Unpacking Heater

    PROPANE CONSTRUCTION HEATER unPacKinG Heater 1. remove heater from carton. 2. Remove all protective packing applied to heater for shipment. 3. Retain cartons and packaging material until unit is operated and found in good condition. 4. Check heater for any shipping damage. If heater shows any external or internal damage, promptly inform dealer/distributor where you purchased heater.
  • Page 7: All Models

    PROPANE CONSTRUCTION HEATER Assembly Components and Instructions for Plastic Base Units: Contents: Tools required for assembly: Assembly Time: All Models: unit, Manual, hose and regulator All Models: adjustable wrench 5 Minutes FA125 Series: phillips head assembly, adjustable leg, 2 height Control Screws FA125 Series Includes: Screw driver 2 Cord Wrap Attachments, 4 Screws (ST3.5x10)
  • Page 8: Size & Capacity Of Propane Cylinders

    PROPANE CONSTRUCTION HEATER inForMation on siZe * caPacity oF ProPane Gas cylinDers: The chart below shows the number and size of propane tanks needed to run this heater. *Less gas is vaporized at lower temperatures. You may need two or more 100 pound tanks or one larger tank in colder weather. (See the parts list for your model of heater to get the specified regulator assembly.) Number of Tanks Temperature...
  • Page 9: Installation To The Propane Gas Tank

    PROPANE CONSTRUCTION HEATER installation to tHe ProPane Gas tanK IMPORTANT: you must use a propane/lp gas supply cylinder that is compatible with the connection device provided with the hose and regulator. regulator propane/lp Supply valve propane/lp Fuel gas Tank Fitting hose to heater hose to regulator...
  • Page 10: Leak Checking & Positioning Heater

    PROPANE CONSTRUCTION HEATER ProPane saFety Propane is safe to use when properly handled. Careless handling of the Propane gas tank could result in fire and/or an explosion. Therefore: • Always keep tank/cylinder securely fastened in an upright position. • Avoid tipping tank on its side when connected to a regulator since this may cause damage to diaphragm in regulator.
  • Page 11: Test Firing Heater & Storage

    PROPANE CONSTRUCTION HEATER sHutDoWn instructions WARNING : Motor and fan must be running before lighting, during operation and at shutdown, in order to prevent a flame-out condition which could result in personal injury or property damage. Turn gas valve knob clockwise to OFF position.
  • Page 12 PROPANE CONSTRUCTION HEATER troublesHootinG TROUBLESHOOTING: PROBLEM POSSIBLE   C AUSE CORRECTIVE   A CTION 1. Control   d ial   i s   o ff   a nd   u nit   i s 1. This   h eater   u ses   a   c on4nuous   s park 1.
  • Page 13: Wiring Diagrams

    PROPANE CONSTRUCTION HEATER WirinG DiaGraMs NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
  • Page 14 PROPANE CONSTRUCTION HEATER WirinG DiaGraMs 100K,125K & 150K Models only 100K,125K & 150KSólo modelos 100K,125K & 150K Les modèles Seulement NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
  • Page 15: Replacement Parts List

    PROPANE CONSTRUCTION HEATER rePlaceMent Parts list MODELS: FA40 Series FA50 Series FA60 Series NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
  • Page 16 PROPANE CONSTRUCTION HEATER rePlaceMent Parts list PART
NUMBER ITEM
No.
 DESCRIPTION 40
SERIES 50
SERIES 60
SERIES INNER
SHELL

ASSEMBLY 2304818 2304818 2304818 NOZZLE *2304829 *2304942 *2325121 FLAME
CAP 2304819 2304819 2325120 THERMAL
SWITCH
BRACKET 2304826 2304826 2304826 THERMAL
SWITCH
 2201373 2201563 2201599 NOZZLE
NUT 2304578 2304578 2304578 SPARK
PLUG
ASSEMBLY 2201375 2201375 2206033 THERMOCOUPLE
ASSEMBLY
(1130/1474‐425L) 2304885 2304885...
  • Page 17: Propane Construction Heater Illustrated / Parts Breakdown

    PROPANE CONSTRUCTION HEATER ProPane construction Heater illustrateD / Parts breaKDoWn MODELS: RMC-FA100DGD RMC-FA125DGD/LPFA125H RMC-FA150DGD NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
  • Page 18 PROPANE CONSTRUCTION HEATER rePlaceMent Parts list PART   N UMBER ITEM           DESCRIPTION No.   100   S ERIES                           125   S ERIES                           150   S ERIES INNER  ...
  • Page 19: Rmc-Fa100Dgp/Dgp-01, Rmc-Fa125Dgp/Dgp-01 & Lpfa125Dgd

    PROPANE CONSTRUCTION HEATER ProPane construction Heater illustrateD / Parts breaKDoWn MODELS: RMC-FA100/DGP/DGP-01 RMC-FA125/DGP/DGP-01 LPFA125DGD NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
  • Page 20 PROPANE CONSTRUCTION HEATER rePlaceMent Parts list PART   N UMBER ITEM           DESCRIPTION No.   FA100DGP FA125DGP LPFA125DGD INNER   S HELL     A SSEMBLY 2304929 2304929 2304929 NOZZLE *2304943 5030077 5030077 FLAME  ...
  • Page 21: Warranty

    Warranty LIMITED WARRANTY: This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale. GHP Group, Inc., at it’s option, will either provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group, Inc., within one (1) year of retail purchase.
  • Page 22: Warranty Registration

    WARRANTY REGISTRATION IMPORTANT: We urge you to fill out your warranty registration card within fourteen (14) days of date of purchase. You can also register your warranty on the internet at www.ghpgroupinc.com. Complete the entire serial number. Retain this portion of the card for your records.

This manual is also suitable for:

ProDelux seriesPro series

Table of Contents

Save PDF