CELLAR & UNDER COUNTER BEER COOLERS
CELLAR & UNDER COUNTER BEER COOLERS
CELLAR & UNDER COUNTER BEER COOLERS
CELLAR & UNDER COUNTER BEER COOLERS
CELLAR & UNDER COUNTER BEER COOLERS
WAYS THE EQUIPMENT SHOULD NOT BE USED
WAYS THE EQUIPMENT SHOULD NOT BE USED
WAYS THE EQUIPMENT SHOULD NOT BE USED
WAYS THE EQUIPMENT SHOULD NOT BE USED
WAYS THE EQUIPMENT SHOULD NOT BE USED
This unit is intended for use as a Cooling and Recirculation unit to Cool Beers, Lagers and Ciders
to the correct serving temperature. They are Designed to be install in the system between the
bulk storage facility (in the cellar or under the Counter of the Bar, depending on unit type) and
the Dispensing head with the Product(s) passing through the Cooling Coil(s) of the Unit. There
are NO other recommended uses for this Equipment.
CORRECT SAFE HANDLING
CORRECT SAFE HANDLING
CORRECT SAFE HANDLING
CORRECT SAFE HANDLING
CORRECT SAFE HANDLING
The weight of this unit is such that care should be taken by a single operator when lifting
the unit to between knuckle and elbow height. Operators should be trained and use correct
lifting techniques at all times. Should the unit need to be transported over a distance then
manual aids should be used. If the distance is long and there are specific difficulties and
risks which prevent the use of manual aids then two people should be considered for this
operation.
UNIT WEIGHT:
UNIT WEIGHT:
UNIT WEIGHT:
UNIT WEIGHT:
UNIT WEIGHT:
CALYPSO
CALYPSO
CALYPSO
WARNING:
WARNING:
WARNING:
WARNING:
WARNING:
IMPORTANT:
IMPORTANT:
IMPORTANT:
IMPORTANT:
IMPORTANT:
The wires in this Mains Lead are coloured in accordance with the following code:
Green and Yellow
Blue
Brown
As the colours of the wires in the mains lead of this appliance may not correspond with the
coloured markings identifying the terminals in the plug proceed as follows:
a
The wire which is coloured Green and Yellow MUST be connected to the terminal in the
plug that is marked with the letter 'E' or by the earth symbol
or coloured green or green and yellow.
b
The wire which is coloured Blue MUST be connected to the terminal in the plug that
is marked with the letter 'N' or coloured Black.
c
The wire which is coloured Brown MUST be connected to the terminal in the plug that
is marked with the letter 'L' or coloured Red.
5
24 Kgs
9
29 Kgs
12
34 Kgs
THIS EQUIPMENT MUST BE EARTHED
THIS EQUIPMENT MUST BE EARTHED
THIS EQUIPMENT MUST BE EARTHED
THIS EQUIPMENT MUST BE EARTHED
THIS EQUIPMENT MUST BE EARTHED
Earth
Neutral
Live
Need help?
Do you have a question about the CALYPSO 9 Mk 2 and is the answer not in the manual?
Questions and answers