8 Bar Pressure Relief Valve; Valve Set Can Be Grouped Two Ways - MEGAFLO Eco Product Manual

Unvented direct & indirect hot water cylinders
Table of Contents

Advertisement

8 Bar Pressure Relief Valve (see Figure 5 below)
This should be installed between the 3 bar Pressure Reducing Valve and the MEGAFLO Eco cylinder. Should a balanced pressure cold water draw off supply be
required for the cold water outlets, this should be taken off between the 3 bar Pressure Reducing Valve and 8 bar Pressure Relief Valve (see Figure
7, p. 14). Branches to drinking water outlets should be taken BEFORE the 8 bar Pressure Relief Valve to avoid the possibility of warm
expanded water being drawn from the tap.
Figure 5 - 8 bar Pressure Relief Valve
From cold water
combination valve
Figure 6 - Valve set can be grouped two ways
Stopcock can be grouped with either
3 bar Pressure Reducing Valve or
8 bar Pressure Relief Valve on the
inlet to either valve only
Stopcock
22mm compression connection
Pressure Relief Valve
discharge connection
T
ake note of flow
direction
Outlet to MEGAFLO Eco
Pressure Relief Valve
"TEE" ( incorporates
Check Valve )
8 bar Pressure Relief
Valve
3 bar Pressure
Reducing Valve
Unvented Hot Water Cylinder
13