Outdoor Swimming Pool Heat Pump Troubleshooting Checklist - Calorex AW629AL Installation Manual

Table of Contents

Advertisement

Installation Manual
AW629/829AL
MAINS
FAULT
DEFROST
WATER FLOW
MAINS
FAULT
DEFROST
WATER FLOW
8.2 Outdoor swimming
pool heat pump trouble-
shooting checklist
Mains Light
Water flow light
Defrost light
Calorex Heat Pumps Ltd. · The Causeway, Maldon, Essex CM9 4XD, UK · Tel: +44 (0)1621 857 171
LAMP
FAN ON COMPRESSOR OFF
RED
ON
AMBER
OFF
WHITE
ON
GREEN
ON
UNIT OPERATES INTERMITTENTLY
RED
ON
ON/OFF Check airflow to machine.
AMBER
WHITE
OFF
GREEN
OFF
Check the status of the warning lights. During normal operation:
The RED mains light should be illuminated
The GREEN water flow light should be illuminated
The AMBER fault light should not be illuminated
The WHITE defrost light should only be illuminated in cold ambient condi-
tions and when the heat pump is carrying out a defrost
If the RED mains light is off, power is not connected to the unit. This light is
wired between the incoming live and neutral cables and therefore illuminates
when the incoming supply is healthy.
If the GREEN water flow light is not illuminated, check for adequate water
flow through the heat pump. Ensure the flow rate from the water pump
exceeds the minimum requirements. Ensure that the pool water bypass
valve (if applicable) is sufficiently closed to achieve minimum flow, isolating
valves to / from the heat pump are fully open and that the sand filter does
not require backwashing.
If the WHITE defrost light is illuminated, the heat pump is carrying out an
automatic defrost to remove ice formed on the evaporator. In air tempera-
tures below 15 °C, automatic defrosting may occur as part of the normal
operation of the heat pump. If abnormal defrost operation is observed, or in
air temperatures above 15 °C:
Page 20
ACTION
Unit on defrost (heating mode) check that air
temperature is not below 7°C.(-15ºC for Y models)
Check evaporator is clean.
Check water and air flows are not restricted, and
that electrical supply is adequate.
Check that linked in external equipment is not the
cause of the fault.