This publication does not in any way warrant description accuracy or guarantee the use for the product to which it refers. Imagine Communications reserves the right, without notice to make such changes in equipment, design, specifications, components, or documentation as progress may warrant to improve the performance of the product.
Introduction This hardware and user guide provides important information for owners of the NEXIO AMP Generation 6 video server, the latest edition of the advanced media platform from Harris Broadcast. This guide includes information for both the Integrated and Shared Storage Transmission Server, the NXAMP3801HDI and NXAMP3801HDX, respectively.
Chapter 1 Introduction NXAMP3801HDX/HDI Software Options The following software options are available for your NXAMP3801HDX/HDI: Software License Upgrades — The software license upgrades enable additional HD or SD channels, and optional Media Applications. Table 1-2 lists the additional software applications that are available for NXAMP3801HDX/HDI: Table 1-2 Optional Software Applications Application Description...
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide Table 1-3 Key Features (Continued) Features Dual port 8 Gbps Fibre Channel support Easy integration with IP networks using Gigabit Ethernet for media transfers ...
Chapter 1 Introduction Table 1-3 Key Features (Continued) Features Single boot drive with an option for a second drive for RAID 1 Software-based codecs for coding and decoding SD and HD media Supports HD-SDI (SMPTE-292M) and AES/EBU interfaces ...
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide Video Table 1-5 describes the NXAMP3801HDX/HDI video specifications: All SD and HD Input/Output Configurations require that you have registered your software. To register your software, see the Software License Card provided with your system. Table 1-5 NXAMP3801HDX/HDI Video Specifications Aspect Ratio Conversion Up/down/cross conversion support...
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide RAID Redundancy Table 1-8 lists both the Integrated and Shared Storage versions of the NXAMP3801HDX/HDI level of redundancy to protect against the failure of one or more storage drives: Table 1-8 RAID Redundancy Specifications Redundancy Specifications ...
Chapter 1 Introduction Remote GPI Control Table 1-10 Table 1-11 describes the GPI control specifications for the NXAMP3801HDX/HDI: Table 1-10 GPI output Specifications for the NXAMP3801HDX/HDI Item Symbol Rating Unit 8 outputs (16 pin connector) Load voltage (AC peak/DC) VOFF Continuous load current ON resistance .8 ohms (typical)
Chassis Components This chapter provides details on the front and back components of the NXAMP3801HDX and NXAPMP3801HDI system. NXAMP3801HDX/HDI Front Panels A description of the front panel is shown in Table 2-1. The front panel of NXAMP3801HDX is shown in Figure 2-1 and front panel of NXAMP3801HDI is shown in Figure 2-2...
Chapter 2 Chassis Components Front Panel - HDI Only Figure 2-2 NXAMP3801HDI Table 2-1 NXAMP3801HDX/HDI Front Panel Item Number Description For Additional Information Figure 2-1 Figure 2-2 LED Indicators used to monitor NEXIO AMP. on page 19 LED Indicators LCD and Keypad LCD and Keypad work together to provide a page 19...
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide Front Panel Components LED Indicators The LED Indicators, Table 2-2, are used to monitor status and health of the frame. For more information on monitoring NXAMP3801HDX/HDI, see Selecting Monitored Diagnostics on page 45.
Chapter 2 Chassis Components Power Off Button: The power off button enables you to shut down the system as described below Power Off — press and hold the power off button for 5 seconds to shut down the system. Arrow Button: The arrow buttons enable you to access information and system status.
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide Refer to the NXUSBLTC User Guide for support of one LTC input per channel and one LTC output per channel. NXUSBLTC is ideal if you want to preserve LTC input timecode from VTRs and other sources, and if you are using downstream devices that require an LTC input, such as closed caption inserters.
Page 22
Chapter 2 Chassis Components Table 2-3 OS and Media Drive RAID Configuration RAID 1 RAID 3 RAID 6 (NXAMP3801HDI) (NXAMP3801HDI) Operating System-Windows 7 Ultimate (64-bit) Optional 1 - 2 Operating System as RAID 1 (Mirroring) protects data from drive failure by simultaneously writing the same data to two hard drives.
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide Table 2-3 OS and Media Drive RAID Configuration (Continued) RAID 1 RAID 3 RAID 6 (NXAMP3801HDI) (NXAMP3801HDI) Optional Optional -or- 1 -2 -plus- 3 -18 Operating System-Windows 7 Ultimate (64-bit). - or- Operating System as RAID 1 (Mirroring) protects data from drive failure by simultaneously writing the same data to two hard drives.
Chapter 2 Chassis Components NXAMP3801HDX/HDI Back Panel This section contains the NXAMP3801HDX/HDI rear panel connectors and their functions: The NXAMP3801HDX/HDI rear panel is shown in Figure 2-6. PLACE HOLDER Figure 2-6 NXAMP3801HDX/HDI Rear Panel The function of each connector is shown in Table 2-4.
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide Table 2-4 NXAMP3801HDX/HDI Rear Panel (Continued) Item Connectors, For Additional Number Indicators, and Description Information Button Figure 2-6 IPMI IPMI lan port IPMI on page 29 RS232 9-pin D-sub connector for RS232 serial port on page 28 RS232 connection.
Chapter 2 Chassis Components Table 2-4 NXAMP3801HDX/HDI Rear Panel (Continued) Item Connectors, For Additional Number Indicators, and Description Information Button Figure 2-6 IN 1 Four HD-BNC connectors for AES/EBU audio AES Audio input. Connect to these ports when using page 27 1/2, 3/4, 5/6, 7/8 AES/EBU audio and Dolby E for input 1.
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide HD/SD SDI Video The HD/SD SDI video ports use BNC connectors for HD-SDI and SDI video input and output. The ports can be configured for SMPTE-259M SD or SMPTE-292M HD outputs. The BNC connectors use coaxial cable to connect devices together.
Chapter 2 Chassis Components USB thumb drives NXAMP3801HDX/HDI supports USB 1.0, 1.1, and 2.0. Refer to the NXUSBLTC User Guide for support of one LTC input per channel and one LTC output per channel. NXUSBLTC is ideal if you want to preserve LTC input timecode from VTRs and other sources, and if you are using downstream devices that require an LTC input, such as closed caption inserters.
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide COM Ports There are eight ports designated for RS-422 communications. They can all be used to control channels on the server. A VTR may be connected to any port. COM PORTS 1 - 8 can be configured to control various channels. (See Table 2-5).
System Installation NXAMP3801HDX/HDI Rack Installation This Chapter provides steps for installing the NXAMP3801HDX/HDI into the rack unit you are using. Please read this Chapter in its entirety before you begin your installation procedures. Rack Location Decide on a suitable location for the rack unit that will hold your NXAMP3801HDX/HDI. It should be situated in a clean, dust-free area that is well ventilated.
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide • Allow the hot plug hard drives and power supply modules to cool before touching them. • Always keep the rack's front door and all panels and components on the system closed when not servicing them to maintain proper cooling.
Chapter 3 System Installation To Rack Mount NXAMP3801HDX/HDI Ensure that the rack is anchored to the floor so that it cannot tip over when NXAMP3801HDX/HDI is extended out of the rack. Figure 3-1 Rack Mounting Remove the slides from the rails. Attach a slide to each side of the NXAMP3801HDX/HDI chassis using seven screws per side.
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide Connecting NXAMP3801HDX/HDI Redundant Power Supplies The NXAMP3801HDX/HDI comes with two power cords that must be only plugged into grounded electrical outlets The NXAMP3801HDX/HDI must be connected to an IT power system. In all cases, make sure that the ...
Chapter 3 System Installation Automatic Updates Harris Broadcast builds and ships Server systems with the Microsoft ® Updates feature turned off. This prevents future operating system updates from automatically installing code which may prevent Harris Broadcast Server systems from operating as expected. The NXAMP3801HDX/HDI system is built on a Windows 7 Ultimate 64-bit platform and, as such, comply with the platform design rules as they existed when the software was built.
Connector Pinouts This chapter provides information on NXAMP3801HDX/HDI pinouts, jumper settings, Weidmüller GPI input and output circuits and connect wiring. COM PORT Pinouts RJ-12 to DB-9 Table 4-1 shows the RJ-12 to DB-9 pinout descriptions for NXAMP3801HDX/HDI. Table 4-1 RJ-12 to DB-9 Adapter RJ-12 DB-9 Connector RJ-12 Connector...
Chapter 4 Connector Pinouts How to Wire Your NEXIO Weidmüller Male Connectors Using a wire stripper, remove no more than 5/16” of the wire installation from each of the required wires. Refer to Figure 4-3. Make sure the installation is clean-cut with no frayed or ragged edges, trim if necessary.
Monitoring Your NXAMP3801HDX/HDI Status Monitoring This chapter describes how to monitor the status of the NXAMP3801HDX/HDI. Remote Monitoring Using IPMI System administrators needing remote access to monitor the performance of the NXAMP3801HDX/HDI can enable the IPMI sub-system available on their server. The IPMI is a special network port available on the back of the NXAMP3810HDX/HDI (see Back Panel Components on page 26) which allows access to the server...
Page 42
Chapter 5 Monitoring Your NXAMP3801HDX/HDI Using the keyboard up or down arrow select Configuration Address source and press the Enter key. In the second Configuration Address source window, using the keyboard up or down arrow, select either Static and go to step 6, or select DHCP and go to step...
Page 43
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide Using the keyboard up or down arrow select Update IPMI LAN configuration. Figure 5-3 BMC Network Configuration Menu Press the Enter key. Figure 5-4 Update IPMI LAN Configuration In the Update IPMI LAN configuration: Use the “+/-”...
Chapter 5 Monitoring Your NXAMP3801HDX/HDI NEXIO Monitor The NEXIO AMP has a local machine monitor software call NEXIO Monitor (Figure 5-5) that runs an application in your Windows system tray (Figure 5-7). Figure 5-5 NEXIO Monitor Icon To Open NEXIO Monitor Right-click on the NEXIO Monitor icon in the system tray.
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide Selecting Monitored Diagnostics The NEXIO Monitor lets you select which diagnostics to monitor. When a fault occurs both the Status and the NEXIO icon will change to one of the four fault icons seen in Table 5-1: Table 5-1.
Chapter 5 Monitoring Your NXAMP3801HDX/HDI LCD Keypad Buttons The LCD Keypad arrow buttons provides system information and helps you monitor NEXIO AMP status. Figure 5-8 LCD Keypad Arrow Buttons The following table shows an example of the information that is displayed in each location. For example, from the home page, if you press the right button 1 time (ending up in the 2across;...
System Drive Recovery System Recovery This Chapter describes the system recovery process using the system recovery image, also called the WIM image. Initial WIM Recovery Image The initial WIM image is captured to the Harris System Recovery USB stick at the customer’s facility during initial system deployment.
Chapter 6 System Drive Recovery From the File menu, select Format Disk. The Format Disk dialog opens. Figure 6-1 Format Disk Dialog From the Assign Letter drop-down list, select only the third-party USB stick From the Format Type drop-down list, select NTFS. Click the FORMAT button to format the third-party USB stick.
Page 49
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Instalation and User Guide On the Harris Recovery Desktop, double-click the Harris Utility Launcher icon. Figure 6-3 Harris Recovery Desktop In the Harris NEXIO Utility Launcher, click the IMAGING button to open the NxImage application. From the File menu, select Capture WIM Image to open the Capture Image dialog.
Chapter 6 System Drive Recovery 14 Click Capture Image button. The progress and status displays in the title bar. 15 When the capture is complete, click Close. If the final WIM image does not fit on the Harris System Recovery USB stick or the third-party USB stick, you can capture the WIM image to a network share.
Page 51
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Instalation and User Guide In the Harris NEXIO Utility Launcher, click the Imaging button to open the NxImage application. From the File menu, select Format Disk to open the Format Disk dialog. Make sure you know which disk you are going to format. Because there may be multiple drives listed, care must be taken not to select the USB stick containing your WIM or any Media drives in your NXAMP3801HDX/HDI server.
Page 52
Chapter 6 System Drive Recovery 16 In the Apply Image dialog, click the Browse button and select the C:\ drive. The drive displays in the Step (2): Select the destination folder or drive to apply the image field. You must use the Browse button to select the destination drive. 17 Click the Apply Image button.
How to Create or Rebuild a RAID 1 Boot Drive Your NEXIO AMP is shipped with only one boot drive. An optional boot drive can be ordered and set up as a mirrored drive known as RAID 1. Creating a New RAID 1 Boot Drive The following procedures will step you through the process of turning a single boot disk into a 2 drive RAID 1 boot volume.
Page 54
Chapter 7 How to Create or Rebuild a RAID 1 Boot Drive Select Create Volume to begin the process. Figure 7-2 Select In the Create Volume window, verify that Intel(R) C600 Series chipset SATA RAID Controller is selected. Verify that Real-Time data protection (RAID 1) under Select Volume Type is selected.
Page 55
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide 13 Click the Next button. Figure 7-4 Confirm Volume Creation 14 Click Create Volume. Figure 7-5 Confirm 15 In the Volume Creation Complete window, click the OK button to confirm The Volume was Created Successfully.
Page 56
Chapter 7 How to Create or Rebuild a RAID 1 Boot Drive 16 Do not reboot your Server. The Migrating process will take 15 to 30 minutes. Figure 7-6 Migrating Data percentage complete 17 When the migration is complete a pop-up message will appear in the tray (Figure 7-7) and the Status will display Normal...
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide Rebuilding a RAID 1 Boot Drive An Icon in the tray (Figure 7-9) show an error. Figure 7-9 Drive error Locate the application through the Microsoft Windows start menu and select Intel Raid Storage enterprise.
Page 58
Chapter 7 How to Create or Rebuild a RAID 1 Boot Drive Install your new hard drive into a carrier. Refer to Under Volume Properties window, click on Rebuild to another disk In the Intel Raid Storage Technology enterprise window, Under Devices window, select Unknown disk (0 GB).
Page 59
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide In the Intel Rapid Storage enterprise window, after the rebuild process has been completed, the unknown drive will no longer be displayed. Figure 7-14 Status Functioning Normal 10 When completed, click on the close button. 175-100423-00...
Page 60
Chapter 7 How to Create or Rebuild a RAID 1 Boot Drive 175-100423-00...
Maintenance This chapter provides safety guidelines, tools and access information about maintaining your NXAMP3801HDX/HDI system. Installation Tools You will need the following tools for the safe and proper installation of your system. Phillips screw driver Anti-static strap Small tip screwdriver ...
Chapter 8 Maintenance Press the power off button on the front panel (Figure 8-1 on page 61) for 5 seconds to remove the power supply to the system. Unplug both power cords from the system or wall outlets to remove the standby power to the system. If necessary, label and disconnect all remaining cables to the NXAMP3801HDX/HDI.
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide Figure 8-3 CR2032 battery location Figure 8-4 Battery replacement direction Hot Swap Power Supplies Your system uses a dual-redundant hot-swappable power supply modules. These power supplies are auto-switching capable and operate at a 100v to 240v input voltage. An illuminated green light indicates that the power supply module is operating, a failed power supply module LED will not be illuminated.
Chapter 8 Maintenance Replacing a Power Supply Module Unplug the power cord before removing the power supply module. Look at the status LED on each plug-in power supply module (Figure 8-5). The LED on the failed power supply module will not be illuminated. Figure 8-5 Power Supply Module To remove a plug-in power supply module: Unplug the AC power cord only to the failed plug-in power supply module.
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide Hard Drive Removal or Replacement The NXAMP3801HDX/HDI comes equipped with hot-swappable hard drives. Only Harris Broadcast qualified hard disk drives are for use in NXAMP3801HDX/HDI chassis. CAUTION- Regardless of how many hard drives are installed, all drive carriers must remain in the drive bays to maintain airflow.
Chapter 8 Maintenance Secure the drive to the carrier with four M3 flat-head screws included in the HDD bag of your accessory box. Figure 8-7 Drive Tray with SSD or Spinner. Insert the drive and drive carrier into its bay vertically, keeping the carrier oriented so that the release button is on the right side.
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide Replacing Media Drive - HDI Only This section provides information on replacing a media drive. Detailed information is provided in the NEXIO LOW LEVEL MODULE USER GUIDE. There is usually no need to stop the LLM to replace the media drive. It is recommended that the system is running throughout the replacement process.
Page 68
Chapter 8 Maintenance After you see the message of BIOS has completed the update: Press and hold the power off button (Figure 8-1 on page 61) for 5 seconds. Unplug the two power cords from the redundant power supplies. Use a grounded wrist strap designed to prevent static discharge when handling components. Loosen the two knurled captive panel screws on the back of the NXAMP3801HDX/HDI (Figure 8-2 on page 62) and slide the cover backwards toward the rear of the chassis.
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide 13 Advanced>CPU Configuration>CPU Power Management Configuration: Power Technology = Disabled Energy/Performance Bias = Disabled 14 Advance>SATA Configuration SATA Mode = RAID Mode 15 Advanced>PCLe/PCI/PnP Configuration Load Onboard Lan 1 = Disabled Load Onboard LAN 2 = Disabled Video Priority = OFF BOARD 16 Press F4 to save and exit.
Page 70
Chapter 8 Maintenance Facing the front of the NXAMP3801: With the Fan connector on your right side (Figure 8-12) and facing down, Insert the new fan (Harris Broadcast part number 131-100005Q00) into the three slots shown identified in Figure 8-13. Figure 8-12 Standalone fan Carefully push down to lock the fan into position per Figure 8-11...
Page 71
NXAMP3801HDX/HDI NEXIO AMP Generation 6 Hardware Installation and User Guide 175-100423-00...
Troubleshooting This chapter provides information about BIOS error beep codes, power supply modules and drive failures. BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors Are those which, in most cases, allow the system to continue the boot-up process.
Chapter 9 Troubleshooting Power Supply Module Failure If a failure occurs with one of the redundant power supply modules, an alarm is generated. It is essential that both power supply modules be connected at all times, therefore it is recommended that the failed module be replaced immediately to maintain full power redundancy.
Need help?
Do you have a question about the Nexio AMP NX3801 HDI Gen6 and is the answer not in the manual?