Minuteman PRO-E User Manual

Minuteman PRO-E User Manual

Pro-e series

Advertisement

PRO-E SERIES
User's Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PRO-E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Minuteman PRO-E

  • Page 1 PRO-E SERIES User's Manual...
  • Page 2: Table Of Contents

    PRO-E Series User's Manual Introduction Controls and Indicators Installation Operation Troubleshooting Replacing the Battery Obtaining Service Specifications Configurable Parameters & Settings Limited Product Warranty Declaration of Conformity © Copyright Para Systems, Inc., 2003...
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS ! Please read this manual before installing your PRO-E Series UPS, models PRO500E, PRO700E, PRO1100E, PRO1500E, PRO500iE, PRO700iE, PRO1100iE, PRO1500iE, as it provides important information that should be followed during installation and maintenance of the UPS and batteries allowing you to correctly set up your system for the maximum safety and performance.
  • Page 4 2. Disconnect the UPS from the AC wall outlet. 3. To de-energize the UPS completely, disconnect the battery. This Uninterruptible Power Supply (UPS) contains potentially hazardous volt- ages. DO NOT attempt to disassemble the UPS. This UPS contains no user serviceable parts.
  • Page 5: Receiving Inspection

    Receiving Inspection After removing your MINUTEMAN UPS from its carton, it should be inspected for damage that may have occurred in shipping. Immediately notify the carrier and place of purchase if any damage is found. Warranty claims for damage caused by the carrier will not be honored. The packing materials that your UPS was shipped in are carefully designed to minimize any shipping damage.
  • Page 6 Press and release the ON/OFF/Test Button after 1 beep to turn the UPS ON or OFF (see section 4). On-Line The On-Line/On-Battery/Boost and Buck (green) LED illuminates in a steady state when the UPS is on and supplying AC power to the load. The LED blinks and the audible alarm sounds, when supplying battery power to the load.
  • Page 7: Rear Panel

    REAR PANEL 120V Models 1. The Information/Rating Label. 2. The Battery Backup and Surge output power receptacles are NEMA 5-15R type (IEC 320 C13 sockets for 230V models). 3. The USB Communications Interface Port is for UPS monitoring and control. 4.
  • Page 8: Installation & Placement

    INSTALLATION PLACEMENT The PRO-E series is intended to be install in a temperature controlled environ- ment that is free of conductive contaminants. Select a location which will pro- vide good air circulation for the UPS at all times. Avoid locations near heating devices, water or excessive humidity, or where the UPS is exposed to direct sunlight.
  • Page 9 Qualified Electrician correct the problem. CHARGING THE BATTERY The PRO-E Series UPS will charge the internal batteries whenever the UPS is connected to an AC source. It is recommended that the UPS's batteries be charged for a minimum of 4 hours before use. The UPS may be used immediately, however, the “ON Battery”...
  • Page 10: Turning The Unit On/Off

    TURNING THE UNIT ON/OFF ON / OFF / Test Button Press and release the ON/OFF/Test Button after one beep to turn the UPS ON and supply power to the load. The load is immediately powered while the UPS runs a two-second self test. Press and release the ON/OFF/Test Button after one beep to turn the UPS OFF.
  • Page 11 ALARMS ON BATTERY When the UPS is operating on the batteries, the On-Battery LED will blink and the audible alarm will sound once every 10-seconds. The alarm will stop once the UPS returns to the On-Line operation. LOW BATTERY WARNING The UPS will sound two beeps every five-seconds when the battery reserve runs low.
  • Page 12 COMMUNICATIONS PORTS (RS232 and USB) The RS232 communication port is a standard DB9 female with both RS232 and simulated contact closure capability. The PRO-E series UPS will poll the port and activate the port for RS232 or contact closure in accordance with the type of cable it finds connected to the port.
  • Page 13: Operation

    Symptom On/Off/Test button not UPS will not turn on pushed UPS operates in Input AC circuit breaker is battery mode only, tripped even though there is normal AC present Fault LED is UPS has detected an illuminated internal fault Incorrect service wiring Site Wiring Fault LED is illuminated The On-line/On-...
  • Page 14: Replacing The Battery

    REPLACING THE BATTERY (AUTHORIZED SERVICE PERSONNEL ONLY) The PRO-E Series UPS has an easy to replace hot-swappable batteries. Please read all of the WARNINGS and CAUTIONS before attempting to service the batteries. NOTE: If there is a power interruption while replacing the hot-swappable batteries, with the UPS on, the load will not be backed up.
  • Page 15: Battery Replacement Procedure

    CAUTION: Replace batteries with the same number and type as originally installed in the UPS. These batteries have pressure operated vents. These UPSs contain sealed non-spillable lead acid batteries. PRO-E PRO500E Model # PRO500iE Battery 1-12V9Ah Model # Panasonic LC-R129...
  • Page 16 9. Disconnect the positive (red) wire from the battery positve terminal. 10. Disconnect the battery negative (black) wire from the battery negative terminal. NOTE: Use CAUTION, do not touch the battery positive wire to the battery negative wire. 11. Remove the battery bracket retaining screw and slide the battery bracket upwards.
  • Page 17 5. Mark the RMA # on the outside of all packages. The factory cannot accept any package without the RMA # marked on the outside. 6. Return the UPS by insured, prepaid carrier to: Para Systems Inc. MINUTEMAN UPS 1455 LeMay Drive Carrollton, TX 75007 ATTN: RMA # _______...
  • Page 18 MODEL NUMBER (230V Models) Acceptable Input voltage Input voltage (AC Mode) Output voltage (AC Mode) Nominal input frequency Input protection Frequency limits (AC Mode) Transfer time Maximum load On-battery output voltage On-battery frequency On-battery waveshape Protection Surge energy rating (one time, 10/1000 uS waveform) Surge current capability (one time, 8/20 uS waveform)
  • Page 19 (These items may require optional software or hardware) Factory Function Default PRO-E UPS ID Date of Battery manufacture install date Battery 1826 life in days Enable/ Enabled Disable auto restart Enabled audible alarm state Shut- UPS output down Type 120VAC...
  • Page 20: Specifications

    Para Systems Inc. (Para Systems) warrants this equipment, when properly applied and operated within specified conditions, against faulty materials or workmanship for a period of three years from the date of purchase. For equip- ment sites within the United States and Canada, this warranty covers repair or replacement of defective equipment at the discretion of Para Systems.
  • Page 21: Limited Product Warranty

    LIMITED PRODUCT WARRANTY (Continued) EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL PARA SYSTEMS BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUEN- TIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, Para Sys- tems is not liable for any costs, such as lost profits or revenue, loss of equip- ment, loss of use of equipment, loss of software, loss of data, cost of substi- tutes, claims by third parties, or otherwise.
  • Page 22: Declaration Of Conformity

    I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s). Robert Calhoun (Name) Manager Engineering (Position) Place: Carrollton, Texas, USA Para Systems, Inc. (MINUTEMAN UPS) 1455 LeMay Drive Carrollton, Texas 75007 USA Robert Calhoun (Signature) Date: April 30, 2003...
  • Page 23 Notes:...
  • Page 24 Para Systems, Inc. 1455 Lemay Dr. Carrollton, TX 75007 Phone: 1-972-446-7363 Fax: 1-972-446-9011 Internet: minutemanups.com UPS Sizing: sizemyups.com PN - 34000226 Rev. 0...

Table of Contents

Save PDF