Page 1
6/2010: Motor Pulley, page 5; Blower Housing, page 4 SUPPORT INFORMATION Training — Plus One http://my.plus1solutions.net/clientPortals/samsung/ Help — GSPN http://service.samsungportal.com/ Samsung Product Support TV http://support-us.samsung.com/spstv/howto.jsp Customer information videos and chat programs Programs for Fridges, Laundry, Ranges & D/W # tsDV419 RevD 03/21/2011...
Dryer continues to run after cycle completed SUBJECT: Dryer belt slides off the pulley when manually rotated counter-clockwise (ccw) Wrinkle Prevent option provides approximately 90 minutes (20 SYMPTOM: The dryer drum will not turn. On occa- continuous and 70 intermittent) of tumbling in unheated air at sions, the customer will rotate the drum counter the end of the cycle to reduce wrinkling.
Page 6
Testing Steam Cycle: Select Wrinkle Care cycle for 4 minutes, check for heat and moisture. If both are present, the dryer is working properly Time and Control Temp. Cooling 1st Heating Resign 1 Spray Resign 2nd Heating Resign 2nd Spray Resign 3rd Heating Resign resign time...
Page 7
Testing Main PCB power output to Heating & Motor circuit. With motor running in the heating mode, read AC voltage across RY6 and RY1. Any voltage reading means Main PCB is defective. See page 4 for Main PCB layout for testing. Testing Motor circuit.
Page 8
Testing Electric Heater circuit. Disconnect Blue wire from RY6, turn power on, start dryer read voltage between RY6 Blue wire and CN6 Green wire. Reading of 120VAC means a proper operating heater circuit. 0VAC means open in circuit. To test thermostats use ohm meter on lowest scale, any resistance replace component See page 4 for Main PCB layout for testing.