DA 220-4
UV
To prevent accidents
and machine damage,
read these instructions
before
installation or use.
M.-Nr. 06 989 050

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA220-4

  • Page 1 Operating and Installation Instructions Ventilation System DA 220-4 To prevent accidents and machine damage, read these instructions before installation or use. M.-Nr. 06 989 050...
  • Page 2: Table Of Contents

    Contents IMPORTANT SAFETY INSTRUCTIONS Functional description Guide to the appliance Operation Turning on the fan ..........10 Selecting the power level.
  • Page 3: Important Safety Instructions

    Read these Operating Instructions carefully before installing or using the Ventilation System. This appliance is intended for residential use only. Use the appliance only for its intended purpose. The manufacturer cannot be held responsible for damages caused by improper use of the hood.
  • Page 4 However, under certain conditions it may be possible for installation in these applications. Please contact the nearest Miele dealer or the Technical Service Department with specific requirements. Before servicing or cleaning the unit, switch power off at the service...
  • Page 5 , WARNING - TO REDUCE THE RISK OF A COOKTOP GREASE FIRE: Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers may ignite. Heat oils slowly on low or medium settings. Always turn the hood on when cooking at a high heat.
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS Installation , WARNING To reduce the risk of fire only use metal ductwork. Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood: –...
  • Page 7: Functional Description

    Functional description The ventilation hood works by air extraction. The air is drawn in and cleaned by the grease filter and directed outside. The hood comes equipped with a non-return flap. This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur.
  • Page 8: Guide To The Appliance

    Guide to the appliance...
  • Page 9: Control Panel

    a Cover plate b Chimney c Canopy d Grease filters e Control panel f Overhead lighting Guide to the appliance g Light button This button turns the light on and off and also dims the light. The lighting can be used independently of the fan.
  • Page 10: Operation

    Operation Turning on the fan ^ Press the On/Off button. Selecting the power level ^ Use the "– / +" controls to select the desired power level. & = increases the fan speed $ = decreases the fan speed Level "1" to "3" (green indicators) are usually sufficient for normal cooking.
  • Page 11 If the power level indicators flash the automatic switch back is not activated. ^ To activate the automatic switch press the "+" button. The power level indicators light. ^ To deactivate the automatic switch press the "–" button. ^ To save the setting press the Delay Shut down button.
  • Page 12: Delayed Shut Down

    Operation Delayed Shut Down If odors or smoke remain in the kitchen after cooking has been completed, the Delayed Shut Down feature can be selected to allow the hood to continue running for either 5 or 15 minutes. ^ Press the Delayed Shut Down button while the fan is still running.
  • Page 13: Turning The Lighting On/Off

    Turning the lighting on/off The overhead lighting can be turned on and off independently from the fan. ^ Press the light button briefly to turn on the lighting. The light button indicator illuminates. ^ Press the light button briefly again to turn off the lighting.
  • Page 14: Filter Timers

    Operation Filter timers A timer monitors the hours of fan operation. The indicator for the grease filter will light after 30 hours of operation. The grease filters must then be cleaned. After the grease filters have been cleaned and put in place, the grease filter timer must be reset.
  • Page 15: Reprogramming The Timers

    Reprogramming the timers The grease filter timer is preset to 30 hours. This time can be lengthened or shortened to 20, 30, 40, or 50 hours. – A time of 20 hours should be programmed in kitchens with frequent pan or deep frying. –...
  • Page 16: Cleaning And Care

    Cleaning and care Before cleaning or servicing the hood, disconnect it from the power supply by either removing the fuse, unplugging it from the outlet or manually "tripping" the circuit breaker. Cleaning the casing Never use abrasive cleaners, scouring pads, steel wool, thinner or caustic (oven) cleaners on the hood.
  • Page 17: Grease Filters

    Grease filters The reusable metal grease filters remove solid particles from the vented kitchen air (grease, dust, etc). The grease filters should be cleaned every 3 - 4 weeks or when the grease filter indicator lights. A dirty filter is a fire hazard. Cleaning and care ^ To remove the grease filters pull the locking clips, 1, forward.
  • Page 18 Cleaning and care Cleaning the grease filter ^ By hand: use a scrub brush with a solution of warm water and mild detergent. Do not use pure detergent, aggressive all purpose cleaners, oven sprays, abrasive cleaning agents or limescale removers. They could destroy the filter.
  • Page 19: Changing The Light Bulb

    Changing the light bulb Before changing the light bulbs, disconnect the hood from the power supply by either removing the fuse, unplugging it, or manually "tripping" the circuit breaker. When in use halogen bulbs become extremely hot, and they can burn your hands.
  • Page 20: After Sales Service

    Miele’s Service department, Extended Service Contracts offered by other providers for Miele products will not be recognized by Miele. Our goal is to prevent unauthorized (and untrained) service personnel from working on your Miele products, possibly doing further damage to them, you and/or your home.
  • Page 21: Installation Instructions

    Installation Instructions...
  • Page 22: Structural Support

    Structural support The ceiling mounting plate will support the weight of the hood. This ceiling plate must be attached to rigid structural framing that is supported in its entirety by the ceiling joists, or to the ceiling joists directly. Do not attach the plate directly to the ceiling with anchors, toggle bolts, etc.
  • Page 23: Electrical Data

    If there is any question concerning the electrical connection of this appliance to your power supply, please consult a licensed electrician or contact Miele’s Technical Service Department. See back cover for contact information. WARNING: THIS APPLIANCE MUST BE...
  • Page 24: Appliance Dimensions

    Appliance dimensions a Mounting bolt holes b Alternative positions to feed through the power cord c Exhaust connection 6" (150 mm) diameter...
  • Page 25: Installation

    Do not install this exhaust hood over cooktops burning solid fuel. Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood: - 22" (550 mm) above electric cooktops, - 30"...
  • Page 26 Installation ½ ^ Cut a 7 " (190 mm) hole in the ceiling centered over the cooktop for the exhaust duct to pass through. The exhaust connection has a 6" (150 mm) diameter. ^ Hold the mounting plate up to the ceiling so that the orange arrow faces the front of the hood and aligns with the line drawn on the ceiling.
  • Page 27: Air Extraction

    If 6" (150 mm) ductwork is not possible then 5" (125 mm) ductwork can be used in conjunction with a reducing collar available from the Miele Technical Service Department (see "Installation / Air extraction" for further details). ^ Drill four "...
  • Page 28 Installation ^ Insert the short edge of the two spring clips into their slots from below and pivot them 90° so that the tab faces the center of the mounting plate. ^ Pull the power cord through the mounting plate. ^ Insert the four flat head screws M 6 x 20 into the recessed holes from above.
  • Page 29 ^ Using at least two people, lift the hood and guide the spring clips through their respective slots in the flange at the top of the chimney. Make sure they click into place and that the hood is hanging securely from the spring clips before allowing them to carry the weight.
  • Page 30 Installation ^ Finally, being careful not to scratch the chimney, push the cover plate upwards until the spring fixing clips click into place. If installed correctly, the cover should be secure and flush against the ceiling. ^ Before using the appliance take out the grease filter and remove the protective foil from the filter frame.
  • Page 31: Air Extraction

    " per foot (1 cm per meter) to prevent condensation dripping into the appliance. – If the exhaust is ducted through an outside wall, a Miele Telescopic Wall Vent can be used.
  • Page 32: Condensate Trap

    Air extraction If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue. Never connect an exhaust hood to an active chimney, dryer vent, vent flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent...
  • Page 33: Caring For The Environment

    Disposal of packing material The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Please recycle. To prevent suffocation of children, ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of their reach.
  • Page 36 Alteration rights reserved / 0607 M.-Nr. 06 989 050 / 00 en - USA For most the updated manual see the Miele website.