Operating instructions for the
DA 8-2 Extractor
M.-Nr. 03 997 810

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA 8-2

  • Page 1 Operating instructions for the DA 8-2 Extractor ]ö M.-Nr. 03 997 810...
  • Page 2: Description Of The Appliance

    Description of the appliance Description of the appliance...
  • Page 3 2nd data plate is supplied. It should be placed into the space pro- vided on page 11 of these instructions. Do not install the DA 8-2 directly next to a gas hob.
  • Page 4: Help Protect Our Environment

    Help protect our environment Help protect our environment Disposal of packaging The transport and protective packing is mostly manufactured from the following re-usable materials: . . . Corrugated paper / cardboard - mostly from recycled materials..Polyethylene foil (PE) - partly from secondary raw materials.
  • Page 5: Table Of Contents

    Contents Contents Description of the appliance ......... 2 Help protect our environment .
  • Page 6: Warning And Safety Instructions

    Warning and safety instructions Warning and safety instructions Before installation and before using the appliance for the first time read these operating instructions care- fully to avoid the risk of accidents and damage to the appliance. The appliance is intended for do- mestic use only.
  • Page 7 Should this occur however, cleaning should only be performed by the Miele Service Department, since the fan cas- ing will have to be taken completely apart.
  • Page 8 Warning and safety instructions Warning and safety instructions Disposal of an old appliance Before disposing of an old ap- pliance, cut the cable off the ap- pliance as close to the housing as possible. The plug and cord should be disposed of and not used elsewhere in the house (electric shock hazard).
  • Page 9: Operation

    Operation Turn the extractor on before starting to cook: Turn the control knob Select a power setting strong enough to clear the air: clockwise. Setting 1 = for normal operation. Setting 2 = for removing heavy cooking odors. After cooking Turn the control knob counter clock- wise to ”0“.
  • Page 10: Cleaning And Care

    Cleaning and care Cleaning and care Before cleaning the extractor dis- connect it from the main electrical supply (pull out the plug or trip the circuit breaker). Grease filter A re-usable metal grease filter is used to remove solid particles (oil, dust, etc.) from kitchen vapors, preventing soiling of the extractor fan.
  • Page 11: After Sales Service

    After Sales Service In the event of problems you cannot correct yourself, please contact Your Miele Dealer The Miele Service Department Space for enclosed data plate After Sales Service The address of the nearest Service De- partment is given on the back page.
  • Page 12: Electrical Connection

    Electrical connection Electrical connection Electrical connection - CDN The extractor is supplied with a 1.10 m power supply cable ready for connec- tion to a 120 VAC, 60 Hz supply. The rated load is 110 W. Fuse rating is 10 A. Caution: Make sure the power supply is OFF during installation.
  • Page 13: Appliance Dimensions

    Appliance dimensions Appliance dimensions 3 3/8" 20 3/16" 14 3/16" 19 5/16" 3 1/16"...
  • Page 14: Installation Instructions

    Installation instructions Installation instructions Do not install the DA 8-2 directly next to a gas hob. This extractor is designed for installa- tion between Combiset appliances. It should always be installed between two appliances, such as the grill and deep fryer.
  • Page 15 One 2 zone + two 4 zone Two 2 zone + two 4 zone Extractor (e.g. DA 8-2) For installation between two appliances: - Dimension B increases by 3-9/16". For installation at the end of a combination: - Dimension B increases by 3-7/8"...
  • Page 16: Exhaust Connection

    These kits are available from the Miele Parts Department. Installation should only be per- formed out by a suitably qualified and trained person.
  • Page 17: Exhaust Connections

    Exhaust connections Vent connection variations 7 1/2" In connection examples B and C, neither the KM 88 nor the KM 89 can be installed to the left of the DA 8, since it will not be possible to place a container beneath the oil drain valve.
  • Page 18 Exhaust connections Exhaust connections Calculation of exhaust ducting A pipe diameter of 5" should ensure trouble-free extraction up to a total pipe length of 5.4. meters (17 1/2 ft). Determine the total pipe length as fol- lows: Measure the total length of ducting needed.
  • Page 20 Alteration rights reserved / 22 / 001 CDN, USA - 4698...