Error
code or
Error contents
message
922.03
Fuser warm-up failure
Fuser type = 1
922.04
Fuser warm-up failure
Fuser type = 1
922.05
After hot roll lamp
detection, did not roll
over to steady state
control in time.
Fuser type = 1
Description/Action
The fuser hot roll does reach
the "final lamp detection"
parameter but not in the
specified time.
The fuser hot roll has timed out
and not reached "final lamp
detection" during the specified
time.
The control code has gotten
lost (this should really be a
software error.
Possible repair actions
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Check all connections on
the fuser and LVPS card
assembly.
4. Replace the fuser unit
assembly if problem
remains. Go to
"Fuser unit
assembly removal (X651,
X652, X654, X656, and
X658)" on page
4-15.
5. Replace the LVPS card
assembly if problem
remains. Go to
"LVPS card
assembly removal (X654,
X656, and X658)" on
page
4-48.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Check all connections on
the fuser and LVPS card
assembly.
4. Replace the fuser unit
assembly if problem
remains. Go to
"Fuser unit
assembly removal (X651,
X652, X654, X656, and
X658)" on page
4-15.
5. Replace the LVPS card
assembly if problem
"LVPS card
remains. Go to
assembly removal (X654,
X656, and X658)" on
page
4-48.
Turn the machine off/on.
Diagnostic information
7462
2-89
Need help?