<< Operating Instructions SATAjet 4000 B RP/HVLP (DIGITAL) >> 10.1 cfm HVLP 15.2 cfm Max. material temperature 122 °F Weight SATAjet 4000 B 21.6 17.3 22.4 SATAjet 4000 B DIGITAL 22.4 18.1 23.2 Compressed air connection G 1/4 Capacity of PVC gravity flow cup...
<< Operating Instructions SATAjet 4000 B RP/HVLP (DIGITAL) >> Design of the Paint Spray Gun [1] [1-1] Paint spray gun handle [1-11] Material flow control screw [1-2] Trigger [1-12] Material flow control counter [1-3] Nozzle set consisting of air cap, fluid tip (not visible),...
Page 12
<< Operating Instructions SATAjet 4000 B RP/HVLP (DIGITAL) >> 6.2. Specific Safety Instructions for Paint Spray Guns Danger! Notice! • Local safety, accident prevention, work and environment protection regulations are mandatory! • Never direct a paint spray gun at human beings or animals! •...
<< Operating Instructions SATAjet 4000 B RP/HVLP (DIGITAL) >> 6.3. Personal Protection Equipment Danger! • When using, cleaning or maintaining the spray gun, always wear approved breathing and eye protection equipment as well as suitable protective gloves, overalls and safety boots! •...
Page 14
10 bar / 145 psi, e.g. Art. No. 53090! Information! The following requirements must be fulfilled: • Use of a compressed air connection G 1/4 a or of a fitting SATA con- nection nipple. • Ensure minimum compressed air volume (air consumption) and pres- sure (recommended spray gun inlet pressure) according to chapter 2.
Page 15
<< Operating Instructions SATAjet 4000 B RP/HVLP (DIGITAL) >> Information! • Use an air hose with minimum 9 mm inner diameter (see warnings), e.g. Art. No. 53090. 1. Check if all screws [2-1], [2-2], [2-3], [2-4] and [2-5] have been tightened firmly.
Page 16
<< Operating Instructions SATAjet 4000 B RP/HVLP (DIGITAL) >> bar higher than the recommended spray gun inlet pressure per every 10 m of air hose (inner width 9 mm). 7.2. Adjustment of the Material Flow [4-1], [4-2], [4-3] und [4-4] - material flow control fully opened...
<< Operating Instructions SATAjet 4000 B RP/HVLP (DIGITAL) >> Danger! Notice! • Drillings should be cleaned with SATA cleaning brushes or SATA nozzle cleaning needles only. The use of other tools may cause damage or may affect the spray pattern. Recommended accessory: cleaning kit Art.
Page 18
[7-1], [7-2], [7-3], [7-4], [7-5] and [7-6] Every SATA nozzle set consists of "paint needle" [7-1], "air cap" [7-2] and "fluid tip" [7-3] and has been hand-adjusted to provide a perfect spray pattern. Therefore, always exchange the complete nozzle set. After installation, please adjust material flow according to chapter 7.2.
Page 19
1. After disassembly, please check air piston rod [10-4] and clean it, if required. If damaged (e.g. if scratched or bent), replace it and grease with SATA high performance spray gun grease (Art. No. 48173) and insert. Please observe correct order of installation! 2.
<< Operating Instructions SATAjet 4000 B RP/HVLP (DIGITAL) >> 9.7. Replacing the Battery (DIGITAL) [12-1] and [12-2] Danger! Risk of explosion! • Replace the battery outside of explosive areas only! • Strictly observe the safety instructions in chapter 6.4.2! According to the intensity of use, the battery will last between 1 to 3 years.
Page 21
<< Operating Instructions SATAjet 4000 B RP/HVLP (DIGITAL) >> Malfunction Cause Corrective action Spray pattern is too Clogged air cap drill- Clean air cap, observe small, crooked, lop- ings chapter 8 sided or splitting Damaged fluid tip (fluid Check if fluid tip is...
Please observe local legislation! 12. After Sale Service Please ask your SATA dealer for accessories, spare parts and technical support. 13. Warranty / Liability...
Seal retainer (air side) 133959 Spring set consisting of 3x paint needle and 3x air piston springs each 133967 Pack of 3 locking screws for SATAjet 4000 B air micrometer (air flow control knob) 133991 Pack of 3 air piston heads 134098...
SATA GmbH & Co. KG Domertalstrasse 20 D-70806 Kornwestheim We hereby declare that the following product in the version sold by SATA, due to its conception, design and construction complies with the basic safety requirements of the directive 94/9/EU including the modifications valid at the time of the declaration, and that it can be used in explosive areas (ATEX), annex X, B, according to EU directive 94/9/EU.
Page 25
<< Operating Instructions SATAjet 4000 B RP/HVLP (DIGITAL) >> explosionsgefährdeten Bereichen - Teil 1: Grundlagen und Anforder- ungen“ (Non-electronic devices for the use in explosive areas - part 1: Basics and Requirements) • DIN EN ISO 12100-1/-2; „Sicherheit von Maschinen, Allgemeine Anfor- derungen“...