Page 9
Flow indicator flap, green Hose clip Intended use FiltoClear 12000/16000/20000/30000, in the following termed "unit", and all other parts from the delivery scope may be used exclusively as follows: − For mechanical and biological cleaning of garden ponds − Operation under observance of the technical data.
Page 10
- GB - Unit configuration and function description Unit configuration Figure Object Water return socket, for the return of filtered pond water Water inlet socket, for the inlet of soiled pond water Cleaning handle, the foam filters are compressed by pulling the handle up UVC unit head with temperature monitor, holder and control window for UV-C lamp.
Page 11
− as a reference value for the fish population in the pond: approx. 60 cm fish length in 1 m³ pond water. − as a pond pump for FiltoClear 12000: Aquamax Eco 8000. − as a pond pump for FiltoClear 16000: Aquamax Eco 10000.
Page 12
− Do not expose the unit to direct sun radiation. − Water return point. OASE recommend: Route the return hose such that the clean water is indirectly returned to the pond, e.g. through a water course. In this manner it will be additionally enriched with oxygen.
Page 13
- GB - Installation Figure (C) 1 ½" hoses or 2" hoses can be connected to the unit. The respective hose connectors are part of our scope of delivery. Recommendation: Use 2" hoses to convey the water through the lines at a minimum pressure loss. If you use a filter starter, fill the product into the container prior to carrying out the following installation steps ( Com- missioning/Start-up).
Page 14
Possible consequence: The unit will be destroyed. Protective measure: Do not connect the unit to a dimmable power supply. OASE recommends the use of BioKick (OASE filter starter bacteria): − For the initial start-up − After manual cleaning of the foam filters −...
Page 15
- GB - Maintenance and cleaning Removing/inserting the UVC unit head Attention! Dangerous electrical voltage. Possible consequences: Death or severe injury. Protective measures: Switch off the mains voltage prior to carrying out work on the unit. Removing the UVC unit head Figure (E) How to proceed: −...
Page 16
− Switch on the UVC unit. Cleaning the unit and washing or replacing the foam filters Wear of the foam filters is caused by mechanical stress and normal ageing. OASE recommend: Replace old foam filters with new ones at the beginning of the new season.
Page 17
- GB - Replacing the UVC lamp Attention! Dangerous electrical voltage. Possible consequences: Death or severe injury. Protective measures: Isolate the unit prior to reaching into the water and carrying out any work on the unit. Secure the unit from being switched on inadvertantly. Attention! Breakable glass.